similar to: Red Alarm - Config Zaptel card

Displaying 20 results from an estimated 7000 matches similar to: "Red Alarm - Config Zaptel card"

2004 Sep 13
1
(no subject)
An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20040913/22b214e9/attachment.htm -------------- next part -------------- hi all, can anyone give solution for this. ?wct1xxp - Digium Wildcard T100P T1/PRI Card 0 zttool gives RED Digium Wildcard T100P T1/PRI Card 0 my zaptel.conf look like this span=1,1,0,esf,b8zs
2004 Sep 12
4
One Question
An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20040913/0d2c3483/attachment.htm -------------- next part -------------- Hi friends, I used following commands to configure my zaptel card 1.modprobe zaptel 2.modprobe wct1xxp 3.ztcfg -vvv 4.zttool the problem is when I type "zttool" command it shows RED
2004 Dec 03
3
Two zaptel T1 cards: no clock from one
List, I have a TE410P (T1 mode, all PRI) and a T100P (fxoks, for fxs channel bank). I cannot seem to get the T100P to send any clock to the channel bank. I prefer that it use the same clock source as the TE410P, but it doesn't matter if it's not in sync just as long as it's there. The TE410P is configured 3x pri_cpe, 1x pri_net. The three cpe go to XO Sonus switch, the net to
2004 Jul 05
2
T1 configuration, getting help via IRC?
In my * server I have a T100P, connected with a T1 crossover cable to an Adtran TA750 with 2 FXO cards. After I do 'modprobe wct1xxp;ztcfg' the alarm on the card starts blinking red. Running zttool confirmed that yes, it is a red alarm. I've read a few previous posts on this type of setup and I'm not too much closer. What should I be checking next? A different cable? The
2004 Jul 02
0
TA750 + T100P configuration. flashing red alarm on t100p after running modprobe wct1xxp, ztcfg
(to mods: sorry for any extra work I've put you through. Posting from my work account, as proper) Hello all, I'm back. I've got that lucky feeling that this will all work out very soon, and I hope that that is true. The issue: In my * server I have a t100P, connected with a T1 crossover cable to an Adtran TA750 with 2 FXO cards. After I do 'modprobe wct1xxp;ztcfg' the alarm
2004 Jul 07
5
E100P
Hi, i just received an E100P, this is the first one I have ever seen, and notice that the board reads T100P. Is this right ? The antistatic bag had a small label that has E100P written on it, and the card is a bit different than the T100P I already have, Does Digium use the same boards for both cards ? I don't have an E1 link here, can I test the card just by loading the driver and run
2003 Sep 05
1
T1 - A little guidance needed to get started, What order to do zaptel, zapata...
I have about a dozen SIP phones up and working, now I want to connect the asterisk box to our Fujitsu 9600 PBX. I currently have two dial-up servers conencted to the Fujitsu PBX that I built with mgetty/pppd and have the lines provisioned the same way as those dial-up server, ESF, B8ZS, and E&M wink start, so I have confidence in the guys who set up the PBX. I've built a loop back plug
2003 Dec 03
2
COnfiguring an * system for a non-profit organization
Hi, Maybe someone has seen this before... I've installed a new T100P, but it doesn't seem to work. I've attached the T100P to an Adtran 750 using a crossover cable. The Adtran shows a red alarm on the T1 interface. The Adtran has been set to factory defaults with FXS cards in 1-3 and an FXO card in 5. The T100P shows no signs of life--the leds are not lit. Should I be seeing
2004 Apr 21
3
T100P + Zap Errors
I am having some difficulty getting a T100P card to work with my PRI. When I attempt to make an outbound call via: exten => 1004,1,Dial(Zap/g1/NPANXXXXXX) I see the following on the asterisk console: -- Executing Dial("SIP/sbruton-b8ce", "Zap/g1/NPANXXXXXX") in new stack Apr 21 08:18:48 NOTICE[16401]: app_dial.c:554 dial_exec: Unable to create channel of type
2003 Oct 14
2
T100P to Adtran TA750 - No dialtone or ring
Hello all, I've got a T100P connected to an Adtran TA750 with a T1 crossover... This connects to a patch panel with phone ports. The Adtran is fully populated with FXS cards. All I get on any phone port is a fast clicking noise... No dialtone. Asterisk 'sees' the card, (the channels show up in /proc/zaptel). Incoming calls are routed to the zap/x channel, but no ring. I'm
2004 Dec 17
1
Red Alarm / Alarm Cleared Zaptel Issue (bug?)
Hello, About every 2 or 3 days I notice in the messages log file: Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 2: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 3: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 4: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 5: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on
2004 Aug 31
4
T100P No D-channels
Hi Last week I installed Asterisk (release1) with digium t100p single span T1 (wct1xxp) board on Dell GX270 pc configured for PRI. Asterisk/t100p is currently the only user of the t1 line. All worked well for about a half a day, PSTN to SIP phones to non-SIP IP phones etc. Alas, since then I consistently get multitudes of blue alarms on all b-channels followed by a loss of d-channel: Aug 31
2003 Aug 25
4
T100P/ TSU 600 installation problem
I have just received a T100P and an Adtran TSU 600 in the mail. I seem to be having a problem with the T100P card. So far I have done the following: vi zaptel.conf fxoks=1-22 fxsks=23-24 ... vi zapata.conf ... signalling=fxo_ks ... channel => 1-22 ... signalling=fxs_ks ... channel => 23-24 I then run modprobe zaptel modprobe wct1xxp ztcfg -vv There are no errors to report. In
2004 Jun 20
2
Channel Bank Frustrations
I'm trying to get a Carrier Access Corp. Channel Bank I working with a Digium T100P without success. What is stranger is that the status lights on the channel bank and T100P seem to change almost each time I power cycle the channel bank or reset the T100P. The channel bank has three status lights: T1, Framing, Status. T1 is green, Status is yellow, and Framing is usually red but sometime
2004 Aug 05
3
Avaya/Lucent Definity -> Asterisk interop question
Calling all Definity admins, Got a few questions about Definity -> Asterisk interoperability. 1) What are the options for integration? Can I hand off extensions from the Definity and vice versa? 2) Anybody have any working configs they would like to post? I've found and read the legacy integration on the wiki about the two systems. I've also googled and found a few threads that were
2003 Jul 31
1
Zaptel cards, working FXS and SIP, no audio?
Greetings again all, With the help of another list member I was able to get the my TDM400P card working properly (and the PRI card loaded too for channels 1-24).
2004 Jan 11
1
possible solution to PRI T100P dropped call issue
To recap: T100P card wouldn't sync with the telco using line side clocking ( span=1,1,0.........) Had to use internal clocking (span=1,0,0.......) zttool showed Tx/Rx Levels as 0/ 1 For the grins of it I replaced the T100P card with another newer card from inventory. This newer card has the same rev on the ASIC / FPGA but doesn't have any of the various jumper headers installed
2005 Mar 08
2
Connect asterisk on classic pbx with T100P card
Hi, I try to connect my asterisk box with a classic pbx (Siemens). I have a T100P E1 card. modprobe zaptel and wct1xxp ok ztcfg -vv ok I can run asterisk and show the channels but the led still flash red My zaptel.conf : span=1,1,0,ccs,hdb3,crc4 bchan=1-15 bchan=17-31 dchan=16 My zapata.conf : ;; E1 switchtype = euroisdn signalling = pri_net group = 1 context=e1 channel => 1-15,17-31
2004 Nov 29
1
New T100P Pri install suggestions?
In the next week or so, we'll be turning up a new T1 Pri from Cox Cable in Omaha using a T100P (installed but not yet configured). While discussing the interface parameters with a very knowledgable Cox engineer, we decided on some of the basics including b8zs, esf, dchan=24, callerid, 5 digits of called number forwarded to *, and switchtype=national (NI2). They indicated their CO switch is a
2004 May 21
5
T100P HDLC configuration
All, I am trying to configure hdlc support on T100P Digium card - everything seems ok... but it just does not work at all. I was able to compile all drivers, the light on the card becomes green when I plug T1 link.... but I even can't ping default router IP... there is no data coming back to me, so I am confused completely now. Also I tried both protocols - raw hdlc and cisco hdlc. The