Displaying 20 results from an estimated 7000 matches similar to: "Problem with T100P card in a new chassis"
2004 Apr 12
5
T100P / ZAP / PRI errors
My PRI is being reset at least once a day with the following errors in the
logs.
zaptel, zapata, libpri, and asterisk are from CVS this morning.. This has
been happening for weeks on all versions (including -stable).
the T100P card appears to NOT be sharing an IRQ.
xenon# cat /proc/interupts
CPU0
0: 1203977 XT-PIC timer
1: 3 XT-PIC keyboard
2:
2004 Apr 22
2
Problems with ADIT600 and T100P
I am having trouble getting my T100P and ADIT 600 talking. I have 2 FXO
8 port cards in the ADIT and a T1 controller card. I have a T1 x-over
cable connecting two together. Here are copies of the relevant bits of
my zaptel.conf and Zapata.conf
Zaptel.conf
span=1,0,0,esf,b8zs
loadzone=us
defaultzone=us
Zapata.cfg
context=default
signalling=fxs_ks
group=1
channel => 1-24
My
2004 Dec 23
4
RedAlarm (t100p - Adtran Total Access 750)
Skipped content of type multipart/alternative-------------- next part --------------
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.0.298 / Virus Database: 265.6.4 - Release Date: 12/22/2004
2004 Apr 25
2
PRI Error T100P
I have seen this posted around the list a few times, but have never
found my exact error or even a solution to this.
I was getting this error every few seconds...... After moving the card
to a different PCI slot and turning off some devices that are not
needed. I was able to get the messages down to about every 10 minutes
and the T1 card now is sitting in it's own intterupt.
Apr 25 23:49:15
2004 Apr 21
3
T100P + Zap Errors
I am having some difficulty getting a T100P card to work with my PRI.
When I attempt to make an outbound call via:
exten => 1004,1,Dial(Zap/g1/NPANXXXXXX)
I see the following on the asterisk console:
-- Executing Dial("SIP/sbruton-b8ce", "Zap/g1/NPANXXXXXX") in new stack
Apr 21 08:18:48 NOTICE[16401]: app_dial.c:554 dial_exec: Unable to create channel of type
2005 Jun 06
5
IRQ Problems
Hello
I just installed a TE110P in a Dell Poweredge 750 (rackmount), which
is connected via crossover T1 cable to a adit 600. Anyway, I've
encountered an array of errors, which I believe I have narrowed down
to the 22 IRQ misses I encounter on zttool. I've noticed that the
te110p and the usb device share an IRQ. Could that be the source of my
woes? Would disabling the usb device in the
2004 Aug 31
4
T100P No D-channels
Hi
Last week I installed Asterisk (release1) with digium t100p single span T1
(wct1xxp) board on Dell GX270 pc configured for PRI. Asterisk/t100p is
currently the only user of the t1 line. All worked well for about a half a
day, PSTN to SIP phones to non-SIP IP phones etc. Alas, since then I
consistently get multitudes of blue alarms on all b-channels followed by a
loss of d-channel:
Aug 31
2003 Apr 09
6
Configuring for outbound calls with PRI on T100P
I run a SIP-only shop with a 23 channel PRI and single T100P.
Here are my configs:
/etc/zaptel.conf:
span=1,0,0,esf,b8zs
bchan=1-23
dchan=24
loadzone = us
defaultzone=us
/etc/asterisk/zapata.conf
[channels]
context=default
switchtype=dms100
signalling=pri_cpe
pridialplan=unknown
rxwink=300 ; Atlas seems to use long (250ms) winks
usecallerid=no
hidecallerid=no
callwaiting=no
2004 Jan 11
1
possible solution to PRI T100P dropped call issue
To recap:
T100P card wouldn't sync with the telco using line side
clocking ( span=1,1,0.........)
Had to use internal clocking (span=1,0,0.......)
zttool showed Tx/Rx Levels as 0/ 1
For the grins of it I replaced the T100P card with
another newer card from inventory.
This newer card has the same rev on the ASIC / FPGA
but doesn't have any of the various jumper headers
installed
2003 Dec 03
2
COnfiguring an * system for a non-profit organization
Hi,
Maybe someone has seen this before...
I've installed a new T100P, but it doesn't seem to work. I've attached
the T100P to an Adtran 750 using a crossover cable. The Adtran shows a
red alarm on the T1 interface. The Adtran has been set to factory
defaults with FXS cards in 1-3 and an FXO card in 5.
The T100P shows no signs of life--the leds are not lit. Should I be
seeing
2003 Oct 14
2
T100P to Adtran TA750 - No dialtone or ring
Hello all,
I've got a T100P connected to an Adtran TA750 with a T1 crossover...
This connects to a patch panel with phone ports. The Adtran is fully
populated with FXS cards.
All I get on any phone port is a fast clicking noise... No dialtone.
Asterisk 'sees' the card, (the channels show up in /proc/zaptel).
Incoming calls are routed to the zap/x channel, but no ring.
I'm
2004 Aug 27
1
Problems dialing out with T100P and Adtran
I have a T100P card connected to an Adtran and then a T1.
I have added the following configurations to Asterisk...but, when I dial
9 and then a local phone number, it bounces between the dial tone and
silence and the *error* light on the Adtran blinks.
zaptel.conf
span=1,0,0,esf,b8zs
fxsks=1-8
loadzone=us
defaultzone=us
zapata.conf
[channels]
context=from-sip
signalling=fxs_ks
2004 Nov 29
1
New T100P Pri install suggestions?
In the next week or so, we'll be turning up a new T1 Pri from Cox Cable
in Omaha using a T100P (installed but not yet configured). While discussing
the interface parameters with a very knowledgable Cox engineer, we decided
on some of the basics including b8zs, esf, dchan=24, callerid, 5 digits
of called number forwarded to *, and switchtype=national (NI2). They
indicated their CO switch is a
2003 Jul 14
2
insmod wcfxo failed ( b8zs, esf, wink start is what I'm trying to do.)
Thanks in advance
root@asterisk01:~# modprobe wcfxo
/lib/modules/2.4.20/misc/wcfxo.o: init_module: No such device
/lib/modules/2.4.20/misc/wcfxo.o: Hint: insmod errors can be caused by
incorrect module parameters, including invalid IO or IRQ parameters.
You may find more information in syslog or the output from dmesg
/lib/modules/2.4.20/misc/wcfxo.o: insmod /lib/modules/2.4.20/misc/wcfxo.o
2004 Jan 10
2
drop calls with T100P / PRI
Hi List,
a number of our customers are reporting dropped calls.
here is the config.
1 T100P T1 Card
1 Asterisk (Mid Nov build)
T1 is signalled as a PRI(National)
The card will only sync up if we clock, if
we line side clock the card goes into yellow alarm
and won't sync up.
the only errors we see are framing slips.
Around 2500 slips over a 18 hour period.
(this was reported from
2004 Dec 03
3
Two zaptel T1 cards: no clock from one
List,
I have a TE410P (T1 mode, all PRI) and a T100P (fxoks, for fxs channel
bank). I cannot seem to get the T100P to send any clock to the
channel bank. I prefer that it use the same clock source as the
TE410P, but it doesn't matter if it's not in sync just as long as it's
there.
The TE410P is configured 3x pri_cpe, 1x pri_net. The three cpe go to
XO Sonus switch, the net to
2004 Jul 06
3
odd behavior - adtran ta 850 + t100p
I've been working with an adtran ta 850 hooked to a t100p pretty much all
day today, and I haven't gotten past configuring zaptel.conf and
zapata.conf. For some reason, when I pick up analog phone hooked up to
the first module of a quad fxs card in the second slot of the ta 850,
asterisk thinks that all four of the fxs modules in that card are going
off hook. If I pick up a phone hooked
2005 Oct 06
3
WCFXO and T1 PRI Card?
Can I have a TDM400 and a T100P in the same machine? I am using AAH and
trying to combine two boxes.
If so, can anyone tell me the proper config for zaptel.conf and
zapata.conf?
Thanks!
Wiley
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20051006/061d9d84/attachment.htm
2004 Nov 27
1
Interfacing T100P with Definity PBX
Hi,
I have two t100p cards installed. One card connected to the PSTN,
the other card is hooked to the Definity PBX with a T1 cross over
cable. The card connected to the PSTN works fine.
The problem is with the card hooked up to the PBX. The light behind
the card is green, but when I dial from this card I get an error. Its
says it could start the D-Channel. Could someone help me out with this
2004 Aug 31
1
T100P Configuration for Mixed Voice & Data
I need to know how to setup the data side of the T1 on my Linux Box. I
have found information about configuring a PRI and HDLC but nothing
about the Frame-Relay type setup for data.
The following is information from our T1 provider.
Network T1:
Framing = ESF
Line code = B8ZS
Build out = 0-133ft(DSX)/0dB(CSU)
Clock = network
Pulse-density-enforce = off
alarm-option = on
alarm-delay = 15