search for: slips

Displaying 20 results from an estimated 1143 matches for "slips".

Did you mean: slip
2005 Nov 08
2
Simple Nesting question/Odd error message
I'm attempting to analyze some survey data comparing multiple docks. I surveyed all of the slips within each dock, but as slips are nested within docks, getting multiple samples per slip, and don't really represent any meaningful gradient, slip is a random effect. There are also an unequal number of slips at each dock. I'm having syntactical issues, however. When I try dock.lme&...
2009 Jul 16
12
Find_all_by and find(:all) to only select certain values for a selection box
So....let''s have a look if I understood the issue: -Find_all_by is actually the same like Find(:all), however Find_all_by is much shorter and less complicated than the syntax of Find(:all) -So in my CONTROLLER it says @files = find(:all) however I don''t want to see all files displayed in my selection box, because I only want to see the foles whose mandant_id is the same like
2013 Dec 06
1
md5sum mismatch between CentOS 6.4 and 6.5 repository
Hello, when I download python-slip-dbus-0.2.20-1.el6_2.noarch.rpm from CentOS 6.5 repository the md5sum is different than when I download same file from 6.4. wget http://msync.centos.org/centos-6/6.5/os/x86_64/Packages/ python-slip-dbus-0.2.20-1.el6_2.noarch.rpm -O python-slip-dbus-0.2.20-1.el6_2.noarch.rpm.65 wget http://msync.centos.org/centos-6/6.4/os/x86_64/Packages/
2003 Jun 30
1
T1 slips/BPVs clarifications (was: Help! Problems talking to upstream switch)
Just some clarification here. On Monday, June 30, 2003 12:04 AM, Steven Critchfield [SMTP:critch@basesys.com] wrote: > > As for slips and bipolar violations... > T1s are just high speed serial lines. A sleep is when you loose sync > with the far side and when you see a 1 come across the line, you may > not > know which bit it was for. A slip is when one end of the circuit is running according to a clock that is fast...
2012 Mar 26
0
CEBA-2012:0413 CentOS 6 python-slip Update
CentOS Errata and Bugfix Advisory 2012:0413 Upstream details at : https://rhn.redhat.com/errata/RHBA-2012-0413.html The following updated files have been uploaded and are currently syncing to the mirrors: ( sha256sum Filename ) i386: 8cc75b3027781a9394d78465ecb95f1b070848e4b096c0857d5bce1a01d477f6 python-slip-0.2.20-1.el6_2.noarch.rpm
2006 Jun 14
5
uninitialized constant error after scaffold on new Windows XP environment
I am attempting to get a working Rails programming environment setup working under XP with MySQL, RadRails and Webrick. I have been using my PowerBook but need to working on Windows environment too. I have basic functions of Ruby and Rails going. I created a really simple table and generated the scaffolding. The server starts just fine. I can browse the database succesfully in RadRails. The issue
2005 Jun 09
1
Zap Clocking - Frame Slips - tdm400p wcfxo zttest cpu spikes spandsp
...r... Flush Complete. Test is approximately 3 minutes. Please wait... 483328 samples in 60.410900 sec. (483288 sample intervals) 99.991722% 483328 samples in 60.410901 sec. (483288 sample intervals) 99.991722% 483328 samples in 60.410899 sec. (483288 sample intervals) 99.991722% Estimate 8 frame slips every 12.083200 seconds. -- snip -- Background: During routine codec/dimensioning testing, I observed a strange, recurring cpu spike occuring appoximately every 12 seconds on a completely idle system with only the zaptel drivers loaded. I used 'vmstat 1' to monitor this. I was using the wc...
1995 Oct 03
0
Dynamic IP with SLIP...
Greetings. After searching through the mailing list archives and reading the SLIP FAQS, I can see that there is no information on the configuration of SLIP for dynamic allocation of IP's. Unfortunately, my provider (school) does not support ppp. SO...SLIP is the only way to go as far as a dialup solution is concerned. Could somebody find it within their hearts to point me to a source of
2005 Oct 11
3
Asterisk and Mitel SX 200 Slip and Frame Err ors causing Major Ala rms
...it's timing from the Mitel. > I'll bet the Mitel is trying to get it's timing from Asterisk. > > Try span=1,0,0,d4,ami and run ztcfg -vvv > I just set this back. It was originally set to your proposed setting but we had been playing around with all the settings to get the slips to go away. This must have been overlooked. Thanks, Geoff
2014 Jan 09
2
How to read IRQs and timing slips values
....c:3099 my_handle_dchan_exception: PRI got event: HDLC Abort (6) on D-channel of span 2 [2014-01-09 17:19:49] NOTICE[26035]: chan_dahdi.c:3099 my_handle_dchan_exception: PRI got event: HDLC Abort (6) on D-channel of span 2 I read an old thread inviting an admin to check for shared IRQs and timing slips. My questions are: 1. cat /proc/interrupts 's output is: # cat /proc/interrupts CPU0 CPU1 CPU2 CPU3 CPU4 CPU5 CPU6 CPU7 0: 90147 0 0 0 0 0 0 0 IO-APIC-edge timer 1:...
2005 Oct 10
2
Asterisk and Mitel SX 200 Slip and Frame Errors causing Major Ala rms
We have integrated an Asterisk (TE110P) and a Mitel SX200. We usually get over 500 frame errors and over a 500 slip errors per hour. When the errors reach 1000 per hour the Mitel will take it's T1 card offline. At that point no calls can be routed from the Asterisk server to the Mitel and the TE110P reports a Yellow alarm. What can be causing all these Frame and Slip errors? We have been
2005 Jan 12
2
T1 Timing Slips
Does anyone know how to monitor * to see if they are receiving timing slips on a span connected to a T100P card? I am seeing b-channel restarts quite often and also getting "No D-channels available" warnings from time to time. Yesterday I had all the b-channels crash during a MeetMe Conference. Not good! This PRI is connected to an Avaya Definity PBX that is o...
2006 May 19
0
SpanDSP issues (oh fun!)
...fine, however anything longer than that will have a failed page about 50% of the time, and anything over 10 pages always has a failed page (except on Xspedius, which has about a 50% fail rate above 10 pages). I have searched everywhere, and the "answer" to this problem seems to be frame slips on the PRI however, all 4 systems are set to sync with the PSTN connection, I'm not running X on any of these systems, (although turning X on doesn't negatively effect them either... IE I get the same number of errors with X running or not). Also, there is no mention anywhere of a "fi...
2007 Jun 26
0
Slip Events
All, I'm using a Digium TE410P w/ Asterisk 1.2.18. Trying to connect it to our NACT STX switch via PRI, d channel is up, T1 shows normal, but I'm getting crazy errors. I rewired this thing three times, then I connected the same cable from the STX to a Cisco AS5300 (same pri settings as asterisk), and all slip events and frame sync errors went away, so the cable is good. STX --> DSX
1998 Oct 01
0
problems accessing samba drives over a SLIP modem line
Hi, I have a wierd problem. Our samba server run on AIX and Solaris, and 1.9.16 or 17 (I think). Everything works fine on our local network. When people come in through an Ascend router using SLIP or PPP however things don't work quite so well. The wierd thing is that if the connecting machine is a Unix box, and there are other PC's on the network on the remote side, net view
2005 Jun 20
2
FXO/FXS cpu spikes, data loss and ztclock.
...ut to registers 7, 8 & 10. This seemed to bring the clock back closer to the true 8 Khz spec and in fact seemed to provide a slightly better clock value than the original crystal. Before the mod, I was seeing CPU spikes once every 12 seconds while ztclock was predicting "Estimate 8 frame slips every 12.083200 seconds." After the mod, I was seeing them once every 15 second while ztclock was predicting "Estimate 8 frame slips every 15.104000 seconds." It certainly seems that there is a direct, predictable relationship here. I'd appreciate any thoughts that others may...
2012 Jan 23
1
Timing Slips CRC & E-Bit Errors - Asterisk - Trixbox 2.8.0.4
Hi, I've searched and searched on the possible problems. If anyone can help me that would be great. Span 1: TE2/0/1 "T2XXP (PCI) Card 0 Span 1" (MASTER) B8ZS/ESF CRC4 error count: 4750 E-bit error count: 5023 Timing slips: 72 1 TE2/0/1/1 Clear (In use) (SWEC: MG2) 2 TE2/0/1/2 Clear (In use) (SWEC: MG2) 3 TE2/0/1/3 Clear (In use) (SWEC: MG2) 4 TE2/0/1/4 Clear (In use) (SWEC: MG2) 5 TE2/0/1/5 Clear (In use) (SWEC: MG2) 6 TE2/0/1/6 Clear (In use) (SWEC:...
2012 Mar 26
0
CentOS-announce Digest, Vol 85, Issue 13
Send CentOS-announce mailing list submissions to centos-announce at centos.org To subscribe or unsubscribe via the World Wide Web, visit http://lists.centos.org/mailman/listinfo/centos-announce or, via email, send a message with subject or body 'help' to centos-announce-request at centos.org You can reach the person managing the list at centos-announce-owner at centos.org When
2009 Feb 20
0
slip r errors nortel switch
I am connected with 5ess to a nortel switch. Running dahdi 2.1.04 and libpri 1.4.7 and asterisk 1.4.22 Everything is working for a short time. The other side reports back to me that he is getting slip-r errors from the TE122P card. After to many errors (like 11) the d channel shuts down on their side. Any idea what to do about this? I have not ran into it before. Jerry
2004 Jan 11
6
T1 Sync clarification
Hi List, After reading a bunch of the docs, list post archives, it still seems that a clear definition of how to clock the T100P card is muddy. zttool says that the link is "INTERNALLY CLOCKED", does this mean the T100P is providing clock, or does this mean the T100P is getting clock from the T1 line side (ergo getting clock from the Telco) ?? If you have sync = 0 then zttool