Displaying 20 results from an estimated 1143 matches for "slip".
Did you mean:
skip
2005 Nov 08
2
Simple Nesting question/Odd error message
I'm attempting to analyze some survey data comparing multiple docks. I
surveyed all of the slips within each dock, but as slips are nested
within docks, getting multiple samples per slip, and don't really
represent any meaningful gradient, slip is a random effect. There are
also an unequal number of slips at each dock.
I'm having syntactical issues, however. When I try
dock.lme...
2009 Jul 16
12
Find_all_by and find(:all) to only select certain values for a selection box
So....let''s have a look if I understood the issue:
-Find_all_by is actually the same like Find(:all), however Find_all_by
is much shorter and less complicated than the syntax of Find(:all)
-So in my CONTROLLER it says @files = find(:all) however I don''t want
to see all files displayed in my selection box, because I only want to
see the foles whose mandant_id is the same like
2013 Dec 06
1
md5sum mismatch between CentOS 6.4 and 6.5 repository
Hello,
when I download python-slip-dbus-0.2.20-1.el6_2.noarch.rpm from CentOS 6.5
repository the md5sum is different than when I download same file from 6.4.
wget http://msync.centos.org/centos-6/6.5/os/x86_64/Packages/
python-slip-dbus-0.2.20-1.el6_2.noarch.rpm
-O python-slip-dbus-0.2.20-1.el6_2.noarch.rpm.65
wget http:/...
2003 Jun 30
1
T1 slips/BPVs clarifications (was: Help! Problems talking to upstream switch)
Just some clarification here.
On Monday, June 30, 2003 12:04 AM, Steven Critchfield
[SMTP:critch@basesys.com] wrote:
>
> As for slips and bipolar violations...
> T1s are just high speed serial lines. A sleep is when you loose sync
> with the far side and when you see a 1 come across the line, you may
> not
> know which bit it was for.
A slip is when one end of the circuit is running according to a clock
that is fas...
2012 Mar 26
0
CEBA-2012:0413 CentOS 6 python-slip Update
...and Bugfix Advisory 2012:0413
Upstream details at : https://rhn.redhat.com/errata/RHBA-2012-0413.html
The following updated files have been uploaded and are currently
syncing to the mirrors: ( sha256sum Filename )
i386:
8cc75b3027781a9394d78465ecb95f1b070848e4b096c0857d5bce1a01d477f6 python-slip-0.2.20-1.el6_2.noarch.rpm
6d592c83d9ea96c519fd7350d7f4d3bfdb91e1932009caca1dc1b79735093c5d python-slip-dbus-0.2.20-1.el6_2.noarch.rpm
67c5087f49d61d66774c573679d75ce3aa229722333161ba5dc39b8cc3f95033 python-slip-gtk-0.2.20-1.el6_2.noarch.rpm
x86_64:
48b297cdc6c036d2752a363aca8784956519e0e2490691b...
2006 Jun 14
5
uninitialized constant error after scaffold on new Windows XP environment
...have any suggestions. I am running a
completely vanilla scaffold.
(2) My MySQL table has just two colums one is an interger and one is a
medium text field. Are there some MySQL datatypes that are not compatible
with Rails?
Thanks!
====================================
uninitialized constant Slip
RAILS_ROOT: ./script/../config/..
Application Trace <http://localhost:3000/admin#> | Framework
Trace<http://localhost:3000/admin#>| Full
Trace <http://localhost:3000/admin#>
c:/ruby/lib/ruby/gems/1.8/gems/activesupport-1.3.1/lib/active_support/dependencies.rb:123:in
`const_missi...
2005 Jun 09
1
Zap Clocking - Frame Slips - tdm400p wcfxo zttest cpu spikes spandsp
I've made some modifications to zttest in order to use
it as a frame clock accuracy tester / slip detector.
I'm not certain if that was it's original purpose, but it
seems that a lot of folks try to use it that way.
The result is something that I'm calling ztclock for now
to help avoid confusion.
I'm including the source at the end of this post. You
can compile it by placing t...
1995 Oct 03
0
Dynamic IP with SLIP...
Greetings.
After searching through the mailing list archives and reading the SLIP FAQS,
I can see that there is no information on the configuration of SLIP for
dynamic allocation of IP's.
Unfortunately, my provider (school) does not support ppp. SO...SLIP is the
only way to go as far as a dialup solution is concerned. Could somebody find
it within their hearts to point me...
2005 Oct 11
3
Asterisk and Mitel SX 200 Slip and Frame Err ors causing Major Ala rms
...it's timing from the Mitel.
> I'll bet the Mitel is trying to get it's timing from Asterisk.
>
> Try span=1,0,0,d4,ami and run ztcfg -vvv
>
I just set this back. It was originally set to your proposed setting but we
had been playing around with all the settings to get the slips to go away.
This must have been overlooked.
Thanks,
Geoff
2014 Jan 09
2
How to read IRQs and timing slips values
....c:3099
my_handle_dchan_exception: PRI got event: HDLC Abort (6) on D-channel of
span 2
[2014-01-09 17:19:49] NOTICE[26035]: chan_dahdi.c:3099
my_handle_dchan_exception: PRI got event: HDLC Abort (6) on D-channel of
span 2
I read an old thread inviting an admin to check for shared IRQs and timing
slips.
My questions are:
1. cat /proc/interrupts 's output is:
# cat /proc/interrupts
CPU0 CPU1 CPU2 CPU3 CPU4
CPU5 CPU6 CPU7
0: 90147 0 0 0 0
0 0 0 IO-APIC-edge timer
1:...
2005 Oct 10
2
Asterisk and Mitel SX 200 Slip and Frame Errors causing Major Ala rms
We have integrated an Asterisk (TE110P) and a Mitel SX200. We usually get
over 500 frame errors and over a 500 slip errors per hour. When the errors
reach 1000 per hour the Mitel will take it's T1 card offline. At that point
no calls can be routed from the Asterisk server to the Mitel and the TE110P
reports a Yellow alarm.
What can be causing all these Frame and Slip errors? We have been working
with a Mite...
2005 Jan 12
2
T1 Timing Slips
Does anyone know how to monitor * to see if they are receiving timing slips
on a span connected to a T100P card? I am seeing b-channel restarts quite
often and also getting "No D-channels available" warnings from time to time.
Yesterday I had all the b-channels crash during a MeetMe Conference. Not
good! This PRI is connected to an Avaya Definity PBX that is...
2006 May 19
0
SpanDSP issues (oh fun!)
I am having classic "frame slip" symptoms on 4 different systems with 4
different providers (all full PRIs, Qwest, XO, Xspedius, and First Digital
are the providers). By classic I mean pages cut short. I do not hear
clicks on calls however, and faxing from a fax machine plugged into the
asterisk box via an fxs port (no VoI...
2007 Jun 26
0
Slip Events
...ing a Digium TE410P w/ Asterisk 1.2.18. Trying to connect it to our NACT STX switch via PRI, d channel is up, T1 shows normal, but I'm getting crazy errors. I rewired this thing three times, then I connected the same cable from the STX to a Cisco AS5300 (same pri settings as asterisk), and all slip events and frame sync errors went away, so the cable is good.
STX --> DSX Panel -->Asterisk
I've confrimed all wiring is good, not sure what the issue is, tried playing with the clock source as well, but no dice. Any ideas?
Errors:
CRC Errors
Frame Sync Errors
Slip Events
1 Error e...
1998 Oct 01
0
problems accessing samba drives over a SLIP modem line
Hi, I have a wierd problem. Our samba server run on AIX and Solaris,
and 1.9.16 or 17 (I think). Everything works fine on our local
network.
When people come in through an Ascend router using SLIP or PPP however
things don't work quite so well.
The wierd thing is that if the connecting machine is a Unix box, and
there are other PC's on the network on the remote side, net view
\\sambaservername lists the shares available just fine.
However, when we try it directly from NT 4.0 SP3, w...
2005 Jun 20
2
FXO/FXS cpu spikes, data loss and ztclock.
...ut to registers 7, 8 & 10. This seemed to bring the clock
back closer to the true 8 Khz spec and in fact seemed to provide
a slightly better clock value than the original crystal.
Before the mod, I was seeing CPU spikes once every 12 seconds
while ztclock was predicting "Estimate 8 frame slips every
12.083200 seconds."
After the mod, I was seeing them once every 15 second while
ztclock was predicting "Estimate 8 frame slips every
15.104000 seconds."
It certainly seems that there is a direct, predictable
relationship here. I'd appreciate any thoughts that others
may...
2012 Jan 23
1
Timing Slips CRC & E-Bit Errors - Asterisk - Trixbox 2.8.0.4
Hi,
I've searched and searched on the possible problems. If anyone can help me
that would be great.
Span 1: TE2/0/1 "T2XXP (PCI) Card 0 Span 1" (MASTER) B8ZS/ESF
CRC4 error count: 4750
E-bit error count: 5023
Timing slips: 72
1 TE2/0/1/1 Clear (In use) (SWEC: MG2)
2 TE2/0/1/2 Clear (In use) (SWEC: MG2)
3 TE2/0/1/3 Clear (In use) (SWEC: MG2)
4 TE2/0/1/4 Clear (In use) (SWEC: MG2)
5 TE2/0/1/5 Clear (In use) (SWEC: MG2)
6 TE2/0/1/6 Clear (In use) (SWEC...
2012 Mar 26
0
CentOS-announce Digest, Vol 85, Issue 13
...Contents of CentOS-announce digest..."
Today's Topics:
1. CEBA-2012:0414 CentOS 6 tcpdump FASTTRACK Update (Johnny Hughes)
2. CEBA-2012:0415 CentOS 6 chkconfig Update (Johnny Hughes)
3. CEBA-2012:0418 CentOS 6 cups Update (Johnny Hughes)
4. CEBA-2012:0413 CentOS 6 python-slip Update (Johnny Hughes)
5. CEBA-2012:0419 CentOS 6 libvirt Update (Johnny Hughes)
----------------------------------------------------------------------
Message: 1
Date: Mon, 26 Mar 2012 13:53:38 +0000
From: Johnny Hughes <johnny at centos.org>
Subject: [CentOS-announce] CEBA-2012:0414...
2009 Feb 20
0
slip r errors nortel switch
I am connected with 5ess to a nortel switch. Running dahdi 2.1.04 and
libpri 1.4.7 and asterisk 1.4.22
Everything is working for a short time.
The other side reports back to me that he is getting slip-r errors from
the TE122P card.
After to many errors (like 11) the d channel shuts down on their side.
Any idea what to do about this?
I have not ran into it before.
Jerry
2004 Jan 11
6
T1 Sync clarification
Hi List,
After reading a bunch of the docs, list post archives, it
still seems that a clear definition of how to clock the T100P
card is muddy.
zttool says that the link is "INTERNALLY CLOCKED",
does this mean the T100P is providing clock, or does
this mean the T100P is getting clock from the T1 line
side (ergo getting clock from the Telco) ??
If you have sync = 0 then zttool