search for: siemens

Displaying 20 results from an estimated 994 matches for "siemens".

2005 Sep 20
6
net rpc vampire / Question or Problem?
...stored. every user is in the primgrp (4126 Users). All Groups (2659) are restored including sids. but no membership is restored! I don't know why. here's my command: net rpc vampire -l -S nt4pdc -W DOMAIN -U user%password Mit freundlichem Gru?, Dirk Laurenz Systems Engineer Fujitsu Siemens Computers S CE DE SE PS N/O Sales Central Europe Deutschland Professional Service Nord / Ost Hildesheimer Strasse 25 30880 Laatzen Germany Telephone: +49 (511) 84 89 - 18 08 Telefax: +49 (511) 84 89 - 25 18 08 Mobile: +49 (170) 22 10 781 Email: mailto:dirk.laurenz@fujitsu-siemens.com Internet: h...
2009 Apr 24
3
timing source problem
hi all, we do have some troubles with zaptel timing source - we have a setup with 3 telco PRI lines, connected to asterisk digium card 0 - asterisk does some handling - calls are leaving on digium card 1 - going to a siemens hipath - there is some call handling - some of the calls then are going from the hipath over a qsig line to a bosch integral PBX - handling the rest of the calls. To be able to get away from the bosch system - we like to put asterisk (1 port free on each card) in the middle of the path siemens -&g...
2005 May 17
3
No Folder browseable
...ked very fine. the problem is that i have to find out, why the upgrade failed before trying to upgrade again. has any tdbfile be changed or why was i not able to browse the shares. they were accessable, mountable but not browsable. Mit freundlichem Gru?, Dirk Laurenz Systems Engineer Fujitsu Siemens Computers S CE DE SE PS N/O Sales Central Europe Deutschland Professional Service Nord / Ost Hildesheimer Strasse 25 30880 Laatzen Germany Telephone: +49 (511) 84 89 - 18 08 Telefax: +49 (511) 84 89 - 25 18 08 Mobile: +49 (170) 22 10 781 Email: mailto:dirk.laurenz@fujitsu-siemens.com Internet: h...
2009 Jan 20
1
Siemens S685IP registration problems
Hi folks, I wonder if any of you out there are using Siemens S685IP base station(s) (with S68H handsets) on Asterisk and experiencing problems with SIP registrations where the SIP extensions do not ring and peers become unreachable after a period of time. Symptoms are rather sporadic, but as described, SIP extensions being unreachable from Asterisk perspec...
2007 Aug 20
2
Asterisk as ISDN PRI Proxy
I have a costumer with a Siemens PBX installed, and I would like to setup a Asterisk system that would act as a kind of Proxy between the Siemens PBX and the operator network. The current setup is: Siemens PBX 2*PRI <-> Operator what I want is: Siemens PBX 2*PRI <-> Asterisk BOX <-> Operator For the Siemens...
2004 Nov 01
2
Problem with 3.0.7 - set_filetime
Hi, a more specific subject... -| -----Original Message----- -| From: -| samba-bounces+dirk.laurenz=fujitsu-siemens.com@lists.samba.o -| rg -| [mailto:samba-bounces+dirk.laurenz=fujitsu-siemens.com@lists -| .samba.org] On Behalf Of Laurenz, Dirk -| Sent: Monday, November 01, 2004 1:48 PM -| To: samba@lists.samba.org -| Subject: [Samba] Problem with 3.0.7 -| -| Hello everybody, -| -| when accessing a...
2005 Sep 01
1
AW: Administrators and Users Rights for Windows workstations
...like 2.) put this group (YOURDOMAIN\Domain Users, YOURDOMAIN\Workstation Admins) into the local group Administrators of each Workstation (you may use vbscript to automate this...) Mit freundlichem Gru?, Dirk Laurenz Systems Engineer PSO - Professional Service Organisation Fujitsu Siemens Computers Hildesheimer Strasse 25 30880 Laatzen Germany Telephone: +49 (511) 84 89 - 18 08 Telefax: +49 (511) 84 89 - 25 18 08 Mobile: +49 (170) 22 10 781 Email: mailto:dirk.laurenz@fujitsu-siemens.com Internet: http://www.fujitsu-siemens.com http://www.fujit...
2006 Nov 29
3
Siemens Gigaset C450 IP vs S450 IP
I've just ordered a Siemens Gigaset C450 IP cordless IP/DECT phone, given that it's supported by asterisk http://www.voipuser.org/review_41.html However, I see that a slightly better Gigaset S450 IP is available for only a slight price premium. Are there any user experiences with the S450 IP? -- Eugen* Leitl <a hr...
2005 Oct 11
4
WINBIND idmap and tdbfiles while upgrading to 3.0.20a
...idmappings, therefor i think winbind wasn't able to read them? Has anyone an idea why this happened? Has anyone had this problem too? There're no entries in the log concering this. The idmap is in a lock idmap tdb file Mit freundlichem Gru?, Dirk Laurenz Systems Engineer Fujitsu Siemens Computers S CE DE SE PS N/O Sales Central Europe Deutschland Professional Service Nord / Ost Hildesheimer Strasse 25 30880 Laatzen Germany Telephone: +49 (511) 84 89 - 18 08 Telefax: +49 (511) 84 89 - 25 18 08 Mobile: +49 (170) 22 10 781 Email: mailto:dirk.laurenz@fujitsu-siemens.com Internet: h...
2008 Oct 12
1
Siemens Series A?
Folks Has anyone any experience with these? http://www.automation.siemens.co.uk/main/business%20groups/power/ups/products/ups%20systems/single%20phase/ http://www.automation.siemens.co.uk/main/business%20groups/power/ups/products/ups%20systems/single%20phase/Siemens%20leaflet%20UPS%20Series%20A.pdf They look a very solid machine, I've got a chance to pick one up for...
2004 Jun 08
2
Integration with a Siemens HiCom 150E / HiPath 3750
Hi * :-) I found in the online WiKi docs some information on how to integrate Asterisk with "old PBX"... http://www.voip-info.org/wiki-Asterisk+legacy+integration ...but I couldn't find anything on integration with a Siemens HiCom 150E. Later on we'll migrate to a HiPath 3750 so information covering this model would be nice too... Do you know if any of the PBX listed on the link above are similar somehow to the Siemens I mention in terms of integration with Asterisk? Answers much appreciated. Martin
2004 Nov 10
0
dos filetimes = yes is not correctly used? - utime function calls fail (Version 3.0.7)
...4-February/034230.html Has anyone a solution for this problem? The directive dos filetimes = yes must be working fine with posix acl. E.g Situation 3 must be working fine and is the preffered setup. Will 3.0.8 solve this issue? Mit freundlichem Gru?, Dirk Laurenz Systems Engineer Fujitsu Siemens Computers Sales Central Europe Deutschland Professional Service Organisation Nord / Ost Hildesheimer Strasse 25 30880 Laatzen Germany Telephone: +49 (511) 84 89 - 18 08 Telefax: +49 (511) 84 89 - 25 18 08 Mobile: +49 (170) 22 10 781 Email: mailto:dirk.laurenz@fujitsu-siemens.com Internet: http:/...
2005 Mar 22
1
[Off-Topic] Siemens!!!
>>Taddei Herve Com MD PD SWC 3 MCH 23 <herve.taddei@siemens.com><<< Wow!!! it seems that Siemens got an eye over speex ;-).... What other company is watching this closely at speex??? :-D just curious.... John Villar Gerente de Proyectos Computadores Flor Hard Soft 2058 C.A. www.florhard.com Taddei Herve Com MD PD SWC 3 MCH 23 wrote: >I...
2005 Sep 09
1
siemens pbx what i ask techinician?
im really newbie, and i have a siemens digital pbx work in my work. i have 4 outside lines and the pbx has a E1/PRI card. what i need to ask my siemens provider(techinicians) to do in the pbx? i only have in my pbx the 9 to get a line to go outside is very simple. but i dont know what i need to ask them to programming. please help me....
2005 Apr 28
2
Roaming Profiles Support: Is it working correctly?
...one and windows stops reading the profile. If you manually change it to rwx for the primary group, windows is able to read it's profile perfectly. The question is now, how to get windows creating it's profile correctly! Mit freundlichem Gru?, Dirk Laurenz Systems Engineer Fujitsu Siemens Computers S CE DE SE PS N/O Sales Central Europe Deutschland Professional Service Nord / Ost Hildesheimer Strasse 25 30880 Laatzen Germany Telephone: +49 (511) 84 89 - 18 08 Telefax: +49 (511) 84 89 - 25 18 08 Mobile: +49 (170) 22 10 781 Email: mailto:dirk.laurenz@fujitsu-siemens.com Internet: h...
2003 Jun 30
1
Asterisk against 3 Com NBX 100 and Siemens HiPath 3700/3750
My new company is going to enter a bid competing with 3Com and Siemens solutions from others. Voice service is a PRI T-1 with a block of 100 DID numbers, a second T1 that will carry Integrated voice/data, 12 voice/768K for redundency. I asked this a week or two ago, now I have more details. Best/$ channel banks that work with Asterisk and Best deal on phones......
2008 Feb 13
2
MWI problem with Siemens Gigaset S675 IP
Hi list, Before purchasing a number of Siemens DECT SIP phones, the Gigaset S675 IP, I read that the problems with MWI had been fixed with the latest firmware version (see http://www.voip-info.org/wiki/view/Siemens+Gigaset+S675IP). Now I'm not so sure that's the case. After setting up a network mailbox for one of these phones,...
2006 Jun 26
2
Asterisk x Siemens HiPath 4000
Hello all. I have installed and functioning asterisk-1.2.9.1 where I effected one upgrade in asterisk-1.0.9, is interconnected with a PABX Siemens HiPath 4000 in ISDN PRI with protocol QSIG, the one that is happening he is that the calls originated for PABX Siemens and destined to SIP phones asterisk are being without audio, nor Ring, is dumb. They could help in this case me? Best Regards Josu? -------------- next part -------------- An HTML...
2006 Jun 27
4
siemens pbx and asterisk
Hello all, I'm new to asterisk. Our company wants to setup an asterisk server and will eventually move to IP centric phones, but they don't want to just throw away the old Siemens PBX, so during the process we want to integrate it with asterisk. Is it possible? and how? thanks. Lito -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20060627/c531f8e5/attachment.htm
2009 Feb 04
3
siemens hipath 4000
I am connecting to a siemens hipath 4000 with dahdi 2.1.0.4 and asterisk 1.4.23 using a Te210P card. the phone guy is saying that the lines are reporting always BUSY. however on my end the status shows OK. Anyone seen this? Is there something different about connecting PRI to siemens hipath? system.conf shows: loadzone=us...