2006 Jun 27
3
Setting MGE powershare attributes
Hi!
We have two MGE Evolution 1100 here, and I want to make use of the
powershare outlets to force a particular boot sequence on the machines
powered by them. However I'm not sure how to set those variables upon
NUT starting, without having to change the init scripts to call
"upsrw".
Is there some place where I can set them, where they can be read
automatically on startup?
One of
2020 Jan 08
0
Hardware compatability report: Eaton Ellipse ECO 1600
Here is a Compatibility Report for the Eaton Ellipse ECO 1600 UPS. Roger
battery.charge: 100
battery.charge.low: 20
battery.runtime: 1575
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse ECO 1600
device.serial: 000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.lowbatt: 37
driver.parameter.offdelay: 30
driver.parameter.ondelay: 40
driver.parameter.pollfreq: 30
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2013 Sep 10
1
[HCL] Eaton 5S1500LCD supported by usbhid-ups
Device Manufacturer: Eaton
Device Name: 5S1500LCD
----------------------------------------------------------
upsc output:
battery.charge: 100
battery.charge.low: 20
battery.runtime: 3515
battery.type: PbAc
device.mfr: EATON
device.model: Ellipse PRO 1500
device.serial: 0000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
2013 Feb 07
0
nut-2.6.5: ups.timer.start problem with EATON Protection Station 650
Hi,
I have successfully configured Nut to work with EATON PS 650: system
detects low battery, initiates shutdown, waits for UPS to switch power off.
However, when power is restored, UPS immediately powers on all power plugs
independently from ups.timer.start setting.
upsc reports "ups.timer.start" variable availability which is set to 0.
upsrw reports "ups.delay.start"
2014 Jun 05
2
Question about voltage threshold setting in NUT
Hello Charles,
Thank you so much for your help. Just run upsc and it is possible that
input.transfer.low is the one because we used power regulator to bring down
the power around 84v and then the ups sent the power loss message to PC. Do
you think some others may take effect for the low voltage? Just have the
upsc result attached.
Then I retried input.transfer.low, default.input.transfer.low,
2006 Jun 09
1
MGE ellipse 1200 config and documentation
Hi,
I have recently purchased MGE ellipse 1200 UPS for my home system. Obviously,
the choice of this particular brand was mainly dictated by MGE's
long-standing support for Linux and NUT project. The fact that the box was
clearly the prettiest looking one on the block did help also ;-). I have had
NUT tools installed and configured in no time, as I did it numerous times
before -- kudos
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
On Fri, Sep 11, 2020, at 4:05 PM, Bartosz wrote:
> Dear All,
>
> Could you please recommend me a UPS with 100% support of the ondelay parameter and NUT compatibility?
>
> 850 or 1000 VA
>
> I have the EATON 5E850iUSBDIN UPS and it does not support this parameter so I would like to buy another UPS that for sure will support it.
>
> Thank you,
> Bart
Can you tell
2014 Jun 05
0
Question about voltage threshold setting in NUT
Hey Charles,
Latest update. Looks like in ups.conf I setup default.input.transfer.low =
84. After I took that line out, restart upsdrvctl, upsmon, and upsd, the
command of
sudo upsrw -s input.transfer.low=70 -u * -p * ups
return OK. Still need to verify if it works by using voltage regulator and
will keep you updated.
Thank you for your help
Regards
Shen
On Thu, Jun 5, 2014 at 8:54 AM,
2010 Feb 22
2
PowerOff on Debian, and driver issues
Hi!
After some problems doing the automatic shutdown of the UPS on Debian, I
have found this Debian bug:
http://bugs.debian.org/cgi-bin/bugreport.cgi?bug=293401
Now I fixed it calling always ups-monitor from the halt script despite
being halt'ed' or powered off (and relying on the POWERDOWNFLAG be set).
Which is the correct aproach or best solution to workarround this bug?
And now my
2007 Feb 01
2
NUT-2.0.3 - problems on setting values
Hello,
we have a MGE Pulsar Evolution 800 connected to a Fedora Core5 Server
using a serial cable.
Installed and configured properly are RPM versions of
nut-2.0.3-0.1.fc5
nut-client-2.0.3-0.1.fc5
nut-cgi-2.0.3-0.1.fc5
which all work (mostly) fine.
The server is connected to outlet.0 and properly shuts down when it's
loosing power after around 20 minutes. It also boots up whenever the ups
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
Hi,
I've been using NUT for many years to look after the UPS on my home
servers. Originally I was using a Compaq R3000 but that was replaced
with an MGE Pulsar Evolution 3000 about a couple of years ago because
the Compaq one was just too noisy!
I'm just setting up a replacement server and would like to connect it
using a serial cable as I've found that the USB connection
2017 Apr 07
2
[Eaton 5S 1500] overvoltage shut down?
>> last night we had what looked like a power spike and 3 machines plugged
>> into 2 Eaton UPS went down instantly. I heard the click the UPS makes when
>> it shuts the load on the ports and then shuts itself down (ie same thing if
>> I simulate with upsmon -fsd). The machines instantly came back, there was no
>> actual downtime, and the machine next to them which is
2007 Aug 11
1
[MGE EVOLUTION 850 VA/ ups 2.0.4] Output.voltage is at 0.0
Hello !
I've just a problem with upsd/upsmon 2.0.4, please have a look at the upsc command:
--------------------
battery.charge: 59
battery.charge.low: 5
battery.runtime: 1312
battery.voltage: 24.0
driver.name: newhidups
driver.parameter.port: auto
driver.version: 2.0.4
driver.version.data: MGE HID 0.9
driver.version.internal: 0.28
input.frequency: 0.0
input.transfer.boost.low: 184.0
2008 Feb 28
1
Plotting Dendrogram Help Getting Plot to Display Neatly
...EXCHANGE IN COM
4 OPTIONSXPRESS HLDGS INC COM
5 SUPERIOR WELL SVCS INC COM
6 HCP INC COM
7 SENIOR HSG PPTYS TR SH BEN INT
8 NATIONWIDE HEALTH PPTYS INC COM
9 DUKE REALTY CORP COM NEW
10 HEALTH CARE REIT INC COM
11 POWERSHARES QQQ TRUST UNIT SER 1
12 FLEXTRONICS INTL LTD ORD
13 VENTAS INC COM
However with 60 cases the names above are not fitting neatly into plot.
Can someone advice on plot
Parameters to fix the size of dendrogram and see the full names on X
axis?
Thanks.
Neil
-------...
2014 Jun 05
0
Question about voltage threshold setting in NUT
On Jun 4, 2014, at 6:38 PM, Shen Chuan wrote:
> $ sudo upsrw -s battery.charge.low=70 -u * -p * ups
> OK
Not sure this does what you originally asked, though.
Does upsc show any settings related to sensitivity?
--
Charles Lepple
clepple at gmail
2008 Apr 01
1
Incorrect battery status on MGE Pulsar M 3000
Hello!
We have two upses: MGE Pulsar M 3000 and MGE Pulsar EXtreme 3200C. They
connect to server by USB. EXtreme works good with usbhid-ups (nut 2.2.1) and
newhidups (nut 2.0.5). But Pulsar M doesn't want to work with usbhid-ups.
- my ups.conf:
[extreme]
driver = usbhid-ups
port = auto
product = "EXtreme"
[pulsar]
driver = usbhid-ups
port =
2007 Oct 29
1
Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
I am running NUT 2.2.0 compiled from the FreeBSD ports tree.
[inchoate 14:50] ~ >upsc ups1 at localhost
battery.charge: 59
battery.charge.low: 20
battery.charge.restart: 0
battery.runtime: 6350
battery.type: PbAc
battery.voltage: 43.0
driver.name: usbhid-ups
driver.parameter.offdelay: 120
driver.parameter.ondelay: 13
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version:
2017 Apr 07
0
[Eaton 5S 1500] overvoltage shut down?
Hello Charles,
I've attached a dump below. There were no long entries on any of the hosts,
neither the one running standalone, nor the master/slave combo, which is
not too surprising, it was really fast: I saw the light flickering in the
room, almost like flash, and all those 3 systems went down. I first heard
the "click" of the ports being disabled, heard the systems shut down, and
2013 Dec 25
2
Delayed UPS start up after shutdown?
On 12/25/2013 12:16 AM, Kris Jordan wrote:
> Angel Tsankov wrote, On 12/24/2013 1:22 AM:
[...]
>> I can see that my UPS (MGE Protection Center 675) has a parameter
>> ups.timer.start (currently holding the strange value of -10). Any idea
>> if this could help and how this parameter can be changed?
>
> in upsrw?
In upsc only. Here's the complete output: