2016 Jan 13
2
[HCL] NHS Laser Senoidal 5000VA supported by gamatronic
...S load or not. It's a value calculated from the UPS to notice the User how much time he have until the UPs battery achieve the depleted status. The battery.run.low can be higher than battery.runtime, do you agree? ----------------------------------------------------------- Thiago Wiezbicki NHS Sistemas de Energia Av. Juscelino Kubitschek de Oliveira, 5270 Cidade Industrial - Curitiba - PR Fone/Fax: +55 41 2141-9262 http://www.nhs.com.br ----- Mensagem original ----- De: "Charles Lepple" <clepple at gmail.com> Para: "Thiago Wiezbicki - NHS" <thiago.wiezbi...
2015 Dec 29
2
[HCL] NHS Laser Senoidal 5000VA supported by gamatronic
Device Manufacturer: NHS Device Name: Laser Senoidal 5000VA upsc output when the UPS is in normal condition: battery.charge: 100 battery.current: 0.4 battery.date: 12292015 battery.runtime: 00000 battery.runtime.low: 59940 battery.temperature: 00 battery.voltage: 163.4 device.mfr: NHS Sistemas de Energia devic...
2016 Jan 08
2
[HCL] NHS Laser Senoidal 5000VA supported by gamatronic
...ime is updated on battery power, This is a dynamic counter that changes with a different load. > Is this fixed at 0, or is there a temperature option? In this case, this UPS doesn't have a temperature sensor, therefore this value is equal zero. > battery.voltage: 163.4 > device.mfr: NHS Sistemas de Energia > device.model: Laser Senoidal 5000VA > device.type: ups > driver.name: gamatronic > driver.parameter.pollinterval: 20 > driver.parameter.port: /dev/ttyACM2 > driver.version: 2.6.3 > driver.version.internal: 0.02 > input.frequency: 59.9 > input.transfe...
2007 Jan 12
5
File Lock Timeout
...apologies; please do not disclose, copy or distribute information in this e-mail or take any action in reliance on its contents: to do so is strictly prohibited and may be unlawful. Please inform us that this message has gone astray before deleting it. Thank you for your co-operation. NHSmail is used daily by over 100,000 staff in the NHS. Over a million messages are sent every day by the system. To find out why more and more NHS personnel are switching to this NHS Connecting for Health system please visit www.connectingforhealth.nhs.uk/nhsmail ******************************...
2016 Jan 06
0
[HCL] NHS Laser Senoidal 5000VA supported by gamatronic
This is the same as https://github.com/networkupstools/nut/issues/254 , right? (It's on my TODO list. DDL updates take a little longer than HCL updates.) Other comments below. > On Dec 29, 2015, at 1:55 PM, Thiago Wiezbicki - NHS <thiago.wiezbicki at nhs.com.br> wrote: > > Device Manufacturer: NHS > Device Name: Laser Senoidal 5000VA > > upsc output when the UPS is in normal condition: > > battery.charge: 100 > battery.current: 0.4 > battery.date: 12292015 > battery.runtime: 00000 Doe...
2014 Nov 12
2
[HCL] NHS Expert C Online 6000 supported by gamatronic
Device Manufacturer: NHS Device Name: Expert C Online 6000 upsc output: battery.charge: 100 battery.current: 0.6 battery.date: 01012014 battery.runtime: 00000 battery.runtime.low: 59940 battery.temperature: 29 battery.voltage: 210.5 device.mfr: NHS Sistemas de Energia device.model: EXPERT GIII 8kVA device.type: ups dri...
2011 Jan 18
2
ggplot2, geom_hline and facet_grid
...I get the plots I would expect. It doesn't seem to make any difference if I get the mean and difference separately. Can anyone explain this and tell me how to avoid it (and why does it work with the Diamonds data set? Any help much appreciated - thanks. Sandy Sandy Small Clinical Physicist NHS Forth Valley and NHS Greater Glasgow and Clyde ******************************************************************************************************************** This message may contain confidential information. If yo...{{dropped:21}}
2014 Nov 17
0
[HCL] NHS Expert C Online 6000 supported by gamatronic
On Nov 12, 2014, at 5:46 AM, Thiago Wiezbicki <thiagowzb at gmail.com> wrote: > > > Device Manufacturer: NHS > Device Name: Expert C Online 6000 > > upsc output: > > battery.charge: 100 > battery.current: 0.6 > battery.date: 01012014 > battery.runtime: 00000 Quick question: does "battery.runtime" update when the device is on battery, or is this field always zero? > b...
2015 Jul 10
0
Apologies for multiple posts
Hi all. I got blocked with the first post and and the message now has been posted multiple times! Sorry about that :( Kind Regards, Keith Begin forwarded message: > From: Mail Delivery System <MAILER-DAEMON at nhs-pd1e-esg106.ad1.nhs.net> > Subject: Undelivered Mail Returned to Sender > Date: 10 July 2015 09:30:06 BST > To: <Keith.Roberts at ecric.nhs.uk> > > This is the mail system at host nhs-pd1e-esg106.ad1.nhs.net. > > I'm sorry to have to inform you that your message...
2014 Nov 22
2
[HCL] NHS Expert C Online 6000 supported by gamatronic
...00 <callto:6000%20,%208000%20,%2010000> and 12000 ( or Expert G III how You can see in upsc output). respectively. battery.charge: 087 battery.current: 0.0 battery.date: 11172014 battery.runtime: 00687 battery.runtime.low: 3780 battery.temperature: 27 battery.voltage: 198.9 device.mfr: NHS Sistemas de Energia device.model: EXPERT GIII 8kVA device.type: ups driver.name: gamatronic driver.parameter.pollinterval: 20 driver.parameter.port: /dev/ttyS0 driver.version: 2.6.3 driver.version.internal: 0.02 input.frequency: 0.0 input.transfer.high: 265 input.transfer.low: 165 input.voltage: 0...
2007 Apr 18
2
Checking validity of NHS numbers
Hello I need to check that the NHS numbers in my database are valid. I''m storing them as ten-digit strings: the first nine are the identifier and the tenth is a check digit. There are four steps to calculating the check digit (from http://www.connectingforhealth.nhs.uk/systemsandservices/nsts/docs/tech_nn_check_digit.pdf):...
2014 Nov 25
1
Test
Sds, Paulo Henrique Cardoso Administrador de Redes - T.I. NHS Sistemas Eletr?nicos Ltda Av. Juscelino Kubitschek de Oliveira, 5270 Cidade Industrial, Curitiba - PR Fone/Fax: (41) 2141-9246/9247 www.nhs.com.br IMPORTANTE: Esta mensagem, incluindo quaisquer anexos, ? endere?ada exclusivamente ao seu destinat?rio e poder? conter informa??es confidenciais....
2007 Nov 09
3
Normalizing grouped data in a data frame
...VEF, ES_Time, Norm_LVEF, Norm_ES_Time ... B,1,7.4, 0.7, 7.4/7.8, 0.7/0.8 B, 3, 7.2, 0.8, 7.2/7.8, 0.8/0.8 B, 4, 7.8, 0.6, 7.8/7.8, 0.6/0.8 ... Where the results of the division would replace the division shown here. I hope this makes sense. If anyone can help I would be very grateful. Sandy Small NHS Glasgow, UK ********************************************************************** This message may contain confidential and privileged information. If you are not the intended recipient please accept our apologies. Please do not disclose, copy or distribute information in this e-mail o...
2014 Nov 23
0
[HCL] NHS Expert C Online 6000 supported by gamatronic
..., 8, 10 and 12 kVA version, and it's names are : Expert C Online 6000 , 8000 , 10000 and 12000 ( or Expert G III how You can see in upsc output). respectively. > I added the 6, 8 and 10 kVA versions to the HCL, but the 12 kVA seems to be part of the Expert S Online series: http://www.nhs.com.br/produtos/c/T0RZPQ==/s/TlRBPQ==/Expert+Isolador Are those the same protocol, just with external battery connections? -- Charles Lepple clepple at gmail -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev...
2014 Nov 26
1
[HCL] NHS Expert C Online 6000 supported by gamatronic
What information Do I need to provide more, beyond upsc and shutdown tests for add these devices on HCL ? Thanks, ------------------------------ Thiago Wiezbicki -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20141125/07793b94/attachment-0001.html>
2016 Jan 09
0
[HCL] NHS Laser Senoidal 5000VA supported by gamatronic
On Jan 8, 2016, at 7:09 AM, Thiago Wiezbicki - NHS <thiago.wiezbicki at nhs.com.br> wrote: > >>> battery.runtime: 00076 >>> battery.runtime.low: 59940 >> >> This seems rather high. This variable is supposed to represent the runtime [in seconds] below which the UPS will signal "LB", but this capture...
2016 Jan 14
0
[HCL] NHS Laser Senoidal 5000VA supported by gamatronic
On Jan 13, 2016, at 6:00 AM, Thiago Wiezbicki - NHS <thiago.wiezbicki at nhs.com.br> wrote: > > The battery.run.low can be higher than battery.runtime, do you agree? I agree with that statement, given what the gamatronic driver is currently reporting. However, I think it should report the elapsed time as battery.runtime.elapsed. I have...
2010 Nov 30
2
ggplot2 histograms
...1,11,12,12,12,13,13,14,15,15,16,16,16,17,17,17,17,18,18,18,18,18) d2<-c(rep("a",25), rep("b",39)) dafr<-data.frame(d1,d2) library(ggplot) qplot(d1, data=dafr, fill=d2, geom='histogram', binwidth = 1) Many thanks for any help Sandy Sandy Small Clinical Physicist NHS Forth Valley and NHS Greater Glasgow and Clyde ******************************************************************************************************************** This message may contain confidential information. If yo...{{dropped:24}}
2010 Jun 17
6
R licensing query
I have recently started a new job at an NHS hospital in Scotland. Since I took up this post 6 months ago I have had an ongoing dispute with the IT secutiry dept. who refuse to install R on my computer. I previously worked in another branch of the NHS where R was widely used and yet there is nothing I can say which will persuade the IT dept...
1999 Jun 03
1
Implementing Shares
...HL 5.2 and Samba 2.0.2. I have the SAMBA acting as the PDC in the network where most of the clients are Win95. Earlier we had a Novell Netware Network and I decided to shift over to Linux/Samba. I am having trouble implementing certain shares. The exact problem is described below: I want ONLY 'nhs' and 'vhs' to have read only access to '/usr/iso9001/edp' directory. Nobody else should be able to view this share. How do I implement this? In the smb.conf file I have the following parameters declared for this share - [ISO-EDP] comment = ISO files for the EDP department...