Displaying 20 results from an estimated 55 matches for "msg_len".
Did you mean:
cmsg_len
2007 Sep 21
2
TrippLite 1500XL problems, continued.
So a month or more ago, I posted about continual disconnect messages from
this UPS (roughly 2/hour), using nut 2.2.0 on debian etch. Now, I've
finally gotten around to running tripplite_usb in debug mode, and these
are the results:
...
send_cmd(msg_len=2, type='L')
send_cmd(msg_len=2, type='S')
send_cmd(msg_len=2, type='B')
send_cmd(msg_len=2, type='L')
send_cmd(msg_len=2, type='S')
send_cmd(msg_len=2, type='B')
send_cmd: send_try = 3, recv_try = 10
Error reading B value: Device detached? (error 0:...
2008 Jan 23
1
empty ups.status on TrippLite SMART1500RMXL2U
...not match - skipping
Checking device (09AE/0001) (002/004)
- VendorID: 09ae
- ProductID: 0001
- Manufacturer: TRIPP LITE
- Product: Tripp Lite SMART1500RMXL2U
- Serial Number: unknown
- Bus: 002
Trying to match device
Device matches
Detected a UPS: TRIPP LITE/ Tripp Lite SMART1500RMXL2U
send_cmd(msg_len=3, type='W')
send_cmd(msg_len=2, type='
send_cmd(msg_len=2, type='S')
send_cmd(msg_len=2, type='P')
send_cmd(msg_len=2, type='F')
send_cmd(msg_len=2, type='V')
send_cmd(msg_len=2, type='V')
send_cmd(msg_len=2, type='U')
Unit ID: 257
Unknow...
2014 Jun 29
1
The dreaded Tripp Lite SMART500RT1U and NUT
...SETINFO device.type "ups"
0.029259 send_to_all: SETINFO driver.version "2.7.2-signed-19-g90e2790"
0.030842 send_to_all: SETINFO driver.version.internal "0.24"
0.031065 send_to_all: SETINFO driver.name "tripplite_usb"
0.031266 send_cmd(msg_len=2, type='
0.031536 send_cmd: sending 3a 00 ff 0d 00 00 00 00 '........'
1.134977 libusb_get_interrupt: Connection timed out
1.136412 libusb_get_interrupt() returned 0 instead of 8 while
sending 3a 00 ff 0d 00 00 00 00 '........'
2.138238 libusb_get_inter...
2012 Dec 07
2
Tripp Lite SMART1000RM2U
...urer: TRIPP LITE
0.054118 - Product: TRIPP LITE SMART1000RM2U
0.054137 - Serial Number: unknown
0.054155 - Bus: 002
0.054172 Trying to match device
0.054431 Device matches
0.060025 Detected a UPS: TRIPP LITE/TRIPP LITE SMART1000RM2U
0.060105 send_cmd(msg_len=2, type='
0.173908 Using SMARTPRO protocol (3003)
0.173939 send_cmd(msg_len=2, type='S')
0.301966 send_cmd(msg_len=2, type='P')
0.430071 send_cmd(msg_len=2, type='F')
0.558070 send_cmd(msg_len=2, type='V')
0.685956 send_c...
2014 Jun 28
0
The dreaded Tripp Lite SMART500RT1U and NUT
On Thu, Jun 26, 2014 at 10:20 PM, Steve Ballantyne
<steve.ballantyne at gmail.com> wrote:
>> However, we don't have all of the 09AE/0001 protocols decoded in the
>> tripplite_usb driver.
>
> I can try to help out on this front? :-)
Definitely.
>> > 9.783126 Unknown input voltage range: 0x02
>> > 9.783308 Unknown number of switchable
2014 Jun 27
3
The dreaded Tripp Lite SMART500RT1U and NUT
...(OK)
> > 9.264042 send_to_all: SETINFO ups.debug.0 "30 05 58 58 58 58 0d
> > '0.XXXX.'"
> > 9.265665 send_to_all: SETINFO ups.firmware.aux "protocol 3005"
>
> Here's that 3005 protocol ID.
>
> > 9.267228 send_cmd(msg_len=3, type='W')
> > 9.267744 send_cmd: sending 3a 57 00 a8 0d 00 00 00 '.W......'
> > 9.370082 send_cmd: received 57 00 0d 00 00 00 00 00 'W.......' (OK)
>
> Your unit might support a watchdog timer.
>
> > 9.370367 send_cmd(msg_l...
2014 Jun 26
1
The dreaded Tripp Lite SMART500RT1U and NUT
...send_to_all: SETINFO device.type "ups"
0.024961 send_to_all: SETINFO driver.version "2.6.4"
0.025174 send_to_all: SETINFO driver.version.internal "0.20"
0.025897 send_to_all: SETINFO driver.name "tripplite_usb"
0.026152 send_cmd(msg_len=2, type='
0.026694 send_cmd: sending 3a 00 ff 0d 00 00 00 00 '........'
1.130244 libusb_get_interrupt: Connection timed out
1.131657 libusb_get_interrupt() returned 0 instead of 8 while
sending 3a 00 ff 0d 00 00 00 00 '........'
2.133695 libusb_get_i...
2009 Nov 08
1
Tripplite INTERNETX525
...0001
- Manufacturer: TRIPP LITE
- Product: TRIPP LITE INTERNETX525
- Serial Number: unknown
- Bus: 002
Trying to match device
Device matches
failed to claim USB device: could not claim interface 0: Device or
resource busy
detached kernel driver from USB device...
Successfully reconnected
send_cmd(msg_len=3, type='W')
send_cmd: sending 3a 57 00 a8 0d 00 00 00 '.W......'
send_cmd: received 57 00 0d 00 00 00 00 00 'W.......' (OK)
send_cmd(msg_len=2, type='
send_cmd: sending 3a 00 ff 0d 00 00 00 00 '........'
send_cmd: received 00 10 01 58 58 58 58 0d '...XXXX....
2006 Jan 13
1
help with TRIPP LITE SMART550USB
...h device
Device matches
HID descriptor retrieved (Reportlen = 52)
Report descriptor retrieved (Reportlen = 52)
Found HID device
Report Descriptor size = 52
Report Descriptor: (200 bytes) => 06 A0 FF 09 01 A1 01 09 02 A1 00 06 A1 FF
09 03
Detected a UPS: TRIPP LITE/TRIPP LITE SMART550USB
send_cmd(msg_len=3, type='W')
send_cmd(msg_len=2, type='
send_cmd(msg_len=2, type='S')
send_cmd(msg_len=2, type='P')
send_cmd(msg_len=2, type='F')
send_cmd(msg_len=2, type='V')
Unknown protocol (2001)Attached to Tripp Lite SMART550USB
send_cmd(msg_len=2, type='S')...
2015 Jan 06
2
libusb drops connection to my Tripp Lite SMART500T1U
...ars.
I ran this ...
/usr/local/ups/bin/tripplite_usb -a SMART500RT1U -u pi -DDDDD 2>&1 |
tee driver-debug-log.txt
Does this snippet of a failure tell you anything? Is there something
I can do to tell the libusb to wait a little longer for the device to
come back?
3116.403776 send_cmd(msg_len=2, type='P')
3116.403858 send_cmd: sending 3a 50 af 0d 00 00 00 00 '.P......'
3116.506490 send_cmd: received 50 30 30 35 30 30 58 0d 'P00500X.' (OK)
3117.449881 send_cmd(msg_len=2, type='S')
3117.451603 send_cmd: sending 3a 53 ac 0d 00 00 00 00 '...
2010 Jan 31
3
smart1050slt by tripp lite
Original Message
>I have 2 SmartUOS1050SLT's that apparently protocol 3004, has there
>been
>any progress on getting these units supported under nut? I am running
>version 2.4.1, and get the following output when starting the driver.
>#lsusb
>Bus 005 Device 002: ID 09ae:0001 Tripp Lite
># upsdrvctl -DDDD start
>Network UPS Tools - UPS driver controller 2.4.1
2007 Mar 04
1
OMNIVS1500XL and FreeBSD
...2)
Found HID device
Report Descriptor size = 52
Report Descriptor: (52 bytes) => 06 a0 ff 09 01 a1 01 09 02 a1 00 06 a1 ff
09 03 09 04 15 80 25 7f 35 00 45 ff 75 08 95 08 81 02 09 05 09 06 15 80 25
7f 35 00 45 ff 75 08 95 08 91 02 c0 c0
Detected a UPS: TRIPP LITE/TRIPP LITE OMNIVS1500XL
send_cmd(msg_len=3, type='W')
send_cmd: sending 3a 57 00 a8 0d 00 00 00 '.W......'
usb_control_msg: 33 9 768 0 0xbfbfe960 8 4000
send_cmd: received 57 00 0d 00 00 00 00 00 'W.......' (OK)
send_cmd(msg_len=2, type='
send_cmd: sending 3a 00 ff 0d 00 00 00 00 '........'
usb_contro...
2016 May 25
2
Tripplite SMART2200VS with tripplite_usb: UPS doesn't shut down
...facturer: TRIPP LITE
0.014799 - Product: TRIPP LITE SMART2200VS
0.014837 - Serial Number: unknown
0.014874 - Bus: 001
0.014911 Trying to match device
0.015272 Device matches
0.016162 Detected a UPS: TRIPP LITE/TRIPP LITE SMART2200VS
0.016267 send_cmd(msg_len=2, type='
0.117454 Using SMARTPRO protocol (3003)
# date; /lib/nut/tripplite_usb -a tripplite -k -DDD
Wed 25 May 12:51:12 CDT 2016
0.000000 debug level is '3'
0.003343 Checking device (09AE/0001) (001/004)
0.014646 - VendorID: 09ae
0.014680 - ProductI...
2016 May 26
2
Tripplite SMART2200VS with tripplite_usb: UPS doesn't shut down
>
> > 2.117586 send_cmd(msg_len=2, type='G')
> > 3.219418 libusb_get_interrupt: Connection timed out
> > 3.219474 libusb_get_interrupt() returned 0 instead of 8 while
> sending 3a 47 b8 0d 00 00 00 00 '.G......'
> > 4.219593 libusb_get_interrupt: Connection timed out
>...
2007 May 11
11
tripp lite smart2200RMXL2U error reading protocol
...]
driver = tripplite_usb
port = /proc/bus/usb/002/002
productid = 3012
bus = 002
desc = "top ups"
I get it to run and find the HID, but it returns the following errors
before quitting:
Detected a UPS: Tripp Lite /TRIPP LITE SMART2200RMXL2U
send_cmd(msg_len=3, type='W')
libusb_get_interrupt() returned 4 instead of 8
libusb_get_interrupt() returned 4 instead of 8
libusb_get_interrupt() returned 4 instead of 8
libusb_get_interrupt() returned 4 instead of 8
libusb_get_interrupt() returned 4 instead of 8
libusb_get_interrupt() returned 4 instead o...
2016 May 25
0
Tripplite SMART2200VS with tripplite_usb: UPS doesn't shut down
...facturer: TRIPP LITE
0.014799 - Product: TRIPP LITE SMART2200VS
0.014837 - Serial Number: unknown
0.014874 - Bus: 001
0.014911 Trying to match device
0.015272 Device matches
0.016162 Detected a UPS: TRIPP LITE/TRIPP LITE SMART2200VS
0.016267 send_cmd(msg_len=2, type='
0.117454 Using SMARTPRO protocol (3003)
# date; /lib/nut/tripplite_usb -a tripplite -k -DDD
Wed 25 May 12:51:12 CDT 2016
0.000000 debug level is '3'
0.003343 Checking device (09AE/0001) (001/004)
0.014646 - VendorID: 09ae
0.014680 - ProductI...
2016 May 26
0
Tripplite SMART2200VS with tripplite_usb: UPS doesn't shut down
On May 25, 2016, at 3:43 PM, Larry Fahnoe wrote:
>
> 0.016075 Initiating UPS shutdown
> 0.016117 soft_shutdown(offdelay=64): N
> 0.016137 send_cmd(msg_len=4, type='N')
The delay command ('N') was sent successfully, so the UPS is receiving commands.
> 2.117586 send_cmd(msg_len=2, type='G')
> 3.219418 libusb_get_interrupt: Connection timed out
> 3.219474 libusb_get_interrupt() returned 0 instead o...
2001 Jun 20
1
SFTP Logging Redux.
...;symlink id %d old %s new %s", id, oldpath, newpath);
+ log("(%d/%d/%s) Symbolic link created: %s -> %s", ppid, cuid, CUNAME, oldpath, newpath);
/* fail if 'newpath' exists */
if (stat(newpath, &st) == -1) {
ret = symlink(oldpath, newpath);
@@ -951,6 +989,7 @@
msg_len = GET_32BIT(cp);
if (msg_len > 256 * 1024) {
error("bad message ");
+ log("(%d/%d/%s) SFTP session closing (%s).", ppid, cuid, CUNAME, "Bad Message");
exit(11);
}
if (buffer_len(&iqueue) < msg_len + 4)
@@ -1036,10 +1075,27 @@
__progname = get_p...
2011 May 23
5
[PATCH 1/6] staging: hv: remove unnecessary code in netvsc_probe().
netif_carrier_off() was called earlier in this function, and there is
no other thread access this device yet. The status checking code is not
necessary here.
Signed-off-by: Haiyang Zhang <haiyangz at microsoft.com>
Signed-off-by: K. Y. Srinivasan <kys at microsoft.com>
Signed-off-by: Abhishek Kane <v-abkane at microsoft.com>
Signed-off-by: Hank Janssen <hjanssen at
2011 May 23
5
[PATCH 1/6] staging: hv: remove unnecessary code in netvsc_probe().
netif_carrier_off() was called earlier in this function, and there is
no other thread access this device yet. The status checking code is not
necessary here.
Signed-off-by: Haiyang Zhang <haiyangz at microsoft.com>
Signed-off-by: K. Y. Srinivasan <kys at microsoft.com>
Signed-off-by: Abhishek Kane <v-abkane at microsoft.com>
Signed-off-by: Hank Janssen <hjanssen at