2016 Nov 01
2
Questions about Eaton 5E 1, 100W 2, 200VA 6-Outlet UPS
> On Oct 31, 2016, at 10:15 PM, Michael Evans <mjevans1983 at gmail.com> wrote:
>
> Are there any other tests I can perform or ways that I can help gather data to get the longer tests supported?
>
The "test.battery.start" command takes a parameter in seconds (defaults to 600):
https://github.com/networkupstools/nut/blob/v2.7.4/driv...
2016 Nov 02
0
Questions about Eaton 5E 1, 100W 2, 200VA 6-Outlet UPS
...ble, I want to target at least one end nearer to the likely
load during normal use as I feel that will increase accuracy of estimate
during normal use.
On Tue, Nov 1, 2016 at 6:23 AM Charles Lepple <clepple at gmail.com> wrote:
>
> > On Oct 31, 2016, at 10:15 PM, Michael Evans <mjevans1983 at gmail.com>
> wrote:
> >
> > Are there any other tests I can perform or ways that I can help gather
> data to get the longer tests supported?
> >
> The "test.battery.start" command takes a parameter in seconds (defaults to
> 600):
>
>
> https://...
2016 Oct 26
2
Questions about Eaton 5E 1, 100W 2, 200VA 6-Outlet UPS
...> ups.delay.start: 180
> ups.load: 0
> ups.productid: 0003
> ups.status: ALARM OL FSD
> ups.type: offline / line interactive
> ups.vendorid: 06da
Thanks, we'll add this to the DDL:
http://networkupstools.org/ddl/
>
> On Tue, Oct 25, 2016 at 10:45 AM Michael Evans <mjevans1983 at gmail.com> wrote:
> I recently purchased a UPS from
> http://www.microcenter.com/product/470131/5E_1,100W_2,200VA_6-Outlet_UPS
>
> It's sold as an Eaton 5E 1,100W 2,200VA 6-Outlet UPS
>
> SKU: 147140
> Mfr Part #: 5E2200USB-LA
> UPC: 743172064875
>
> &quo...
2016 Oct 26
0
Questions about Eaton 5E 1, 100W 2, 200VA 6-Outlet UPS
....nominal: 120
output.voltage: 0.0
ups.alarm: Shutdown imminent!
ups.beeper.status: enabled
ups.delay.shutdown: 30
ups.delay.start: 180
ups.load: 0
ups.productid: 0003
ups.status: ALARM OL FSD
ups.type: offline / line interactive
ups.vendorid: 06da
On Tue, Oct 25, 2016 at 10:45 AM Michael Evans <mjevans1983 at gmail.com>
wrote:
> I recently purchased a UPS from
> http://www.microcenter.com/product/470131/5E_1,100W_2,200VA_6-Outlet_UPS
>
> It's sold as an Eaton 5E 1,100W 2,200VA 6-Outlet UPS
>
> SKU: 147140
> Mfr Part #: 5E2200USB-LA
> UPC: 743172064875
>
> "T...
2016 Oct 25
2
Questions about Eaton 5E 1, 100W 2, 200VA 6-Outlet UPS
I recently purchased a UPS from
http://www.microcenter.com/product/470131/5E_1,100W_2,200VA_6-Outlet_UPS
It's sold as an Eaton 5E 1,100W 2,200VA 6-Outlet UPS
SKU: 147140
Mfr Part #: 5E2200USB-LA
UPC: 743172064875
"The Eaton 5E is an essential line interactive UPS that provides cost
effective and reliable power protection against power outages and bad power
quality. Thanks to its small
2016 Nov 01
0
Questions about Eaton 5E 1, 100W 2, 200VA 6-Outlet UPS
I can't seem to get the longer battery tests to actually run:
test.battery.start
test.battery.start.deep
Both appear to leave the battery voltage at line-power levels; while the
quick test does have a notable voltage delta.
Are there any other tests I can perform or ways that I can help gather data
to get the longer tests supported?
I borrowed a 60W light bulb (instead of one of the