Displaying 20 results from an estimated 148 matches for "maxpow".
Did you mean:
maxrow
2011 Apr 08
1
Listing shut off domains
...orkstation.
The original code needs to list all the domains available on the local
machine, no matter what their state is. The problem is that the shut off
domains are not shown by the virsh commands on the VMWare Workstation
system.
On the KVM system, with one shut off domain, I get this output:
maxpower at sw ~$ virsh list --all
Id Name State
----------------------------------
- 00042-my-domain shut off
On the VMWare Workstation system, with one shut off domain, I get this
output:
maxpower at sw2 ~ $ virsh -c vmwarews:///session list --all
Id Name State
-----...
2008 Dec 01
1
Unitek Self Protek Mistral 1000ipF
...figurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 25
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xe0
Self Powered
Remote Wakeup
MaxPower 0mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 9 Hub
bInterfaceSubClass 0 Unused
bInterfaceP...
2013 Jan 13
0
Evolution 850 not recognized by NUT 2.6.5?
...igurations ? ? ?1
? Configuration Descriptor:
? ? bLength ? ? ? ? ? ? ? ? 9
? ? bDescriptorType ? ? ? ? 2
? ? wTotalLength ? ? ? ? ? 25
? ? bNumInterfaces ? ? ? ? ?1
? ? bConfigurationValue ? ? 1
? ? iConfiguration ? ? ? ? ?0?
? ? bmAttributes ? ? ? ? 0xe0
? ? ? Self Powered
? ? ? Remote Wakeup
? ? MaxPower ? ? ? ? ? ? ? ?0mA
? ? Interface Descriptor:
? ? ? bLength ? ? ? ? ? ? ? ? 9
? ? ? bDescriptorType ? ? ? ? 4
? ? ? bInterfaceNumber ? ? ? ?0
? ? ? bAlternateSetting ? ? ? 0
? ? ? bNumEndpoints ? ? ? ? ? 1
? ? ? bInterfaceClass ? ? ? ? 9 Hub
? ? ? bInterfaceSubClass ? ? ?0 Unused
? ? ? bInterfaceP...
2007 Aug 19
4
OMRON BX35F
Hi nut-upsdev,
I have just got OMRON BX35F. Only object
files and usage information is included.
Where should I start to help you to get it
supported? Any interest in supporting it at all?
2007 May 05
1
powermust usb
...figurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 25
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xe0
Self Powered
Remote Wakeup
MaxPower 0mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 9 Hub
bInterfaceSubClass 0 Unused
bInterfaceP...
2016 Jul 26
0
Two UPS with same vendor ID
...nfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 3 (error)
bmAttributes 0x80
(Bus Powered)
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass...
2008 Feb 01
2
Four UPS's via usb.
> Hello everyone. I try to connect four PowerMust 2000 ups's via usb to one
> computer using megatec_usb driver. But megatec_usb completly ignores port
> directive in ups.conf, I even try port = /dev/null and megatec_usb founds
> ups and it works.
The 'port' is not used for USB connected devices, it's only needed for
compatibility reasons.
> Problem is that
2006 Jul 24
1
Fw: INFOSEC 500 XP en USB et drivers newhidups avec '-x generic'
...gurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 3
bmAttributes 0x80
(Bus Powered)
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Devices
bInterfaceSu...
2010 Apr 01
1
amacrox ap1000 problems
...idVendor 0?0665
idProduct 0?5161
bcdDevice 0.02
iManufacturer 1 Cypress Semiconductor
iProduct 2 USB to Serial
iSerial 0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 3
bmAttributes 0?80
(Bus Powered)
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 0 No Subclass
bInterfaceProtocol 0 None
iInterface 4 Sample HID
** UNRECOGNIZED: 09 21 00 01 00 01 22 1b 00
Endpoint Descripto...
2010 Sep 16
1
Soyntec Sekury A600 VA
...0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 3
bmAttributes 0x80
(Bus Powered)
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 0 No Su...
2009 Mar 04
3
Nut with megatec_usb
...bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 41
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 4 Sample HID
bmAttributes 0x80
(Bus Powered)
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 2
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 0 No Su...
2009 Mar 04
3
Nut with megatec_usb
...bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 41
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 4 Sample HID
bmAttributes 0x80
(Bus Powered)
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 2
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 0 No Su...
2014 Sep 06
0
NUT Quit Working [Tripp Lite; USB 3.0]
On Sep 6, 2014, at 4:16 PM, Leslie Rhorer <lrhorer at mygrande.net> wrote:
> Oh, hey! That seems to have worked. I'm sure the UPS got plugged into a different port one of the (many) times the server was removed from the relay rack, and it was on a USB 3.0 port. I moved it to a 1.0 port and everything seems to be working just fine.
The specifics of the motherboard and its USB
2006 Apr 11
2
SOS : Help needed for UPS Centralion Blazer 2000VA USB
...Cypress Semiconductor
Speed: 1,5 Mb/s (low)
USB Version: 1.10
Device Class: 00(ifc )
Device Subclass: 00
Device Protocol: 00
Maximum Default Endpoint Size: 8
Number of Configurations: 1
Vendor Id: 0665
Product Id: 5161
Revision Number:0.02
Config Number: 1
Number of Interfaces: 1
Attributes: 80
MaxPower Needed: 100mA
Interface Number: 0
Name: hid
Alternate Number: 0
Class: 03(HID )
Sub Class: 0
Protocol: 0
Number of Endpoints: 1
Endpoint Adderss: 81
Direction: in
Attribute: 3
Type: Int.
Max Packet Size: 8
Interval: 32ms
If someone could help me, it'll be rea...
2006 Apr 11
2
SOS : Help needed for UPS Centralion Blazer 2000VA USB
...Cypress Semiconductor
Speed: 1,5 Mb/s (low)
USB Version: 1.10
Device Class: 00(ifc )
Device Subclass: 00
Device Protocol: 00
Maximum Default Endpoint Size: 8
Number of Configurations: 1
Vendor Id: 0665
Product Id: 5161
Revision Number:0.02
Config Number: 1
Number of Interfaces: 1
Attributes: 80
MaxPower Needed: 100mA
Interface Number: 0
Name: hid
Alternate Number: 0
Class: 03(HID )
Sub Class: 0
Protocol: 0
Number of Endpoints: 1
Endpoint Adderss: 81
Direction: in
Attribute: 3
Type: Int.
Max Packet Size: 8
Interval: 32ms
If someone could help me, it'll be rea...
2008 Jan 07
1
INFOSEC 500 XP usb support
....1
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 25
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xe0
Self Powered
Remote Wakeup
MaxPower 0mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 9 Hub
bInterfaceSubClass 0 Unused
bInterfaceProtocol...
2007 Feb 23
2
how do I find the association between a usb port and a /dev entry?
...0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xc0
Self Powered
MaxPower 20mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Devices
bInterfaceSubClass 0 No S...
2016 May 31
2
cannot get APC ups status change via usb cable from RaspberryPi
Hi All,
I get very strange UPS problem from RspberryPI mode B
(both version 2 and 3).
Here is our environment:
OS: Raspbian 8.0, Ubuntu 16.04 and Ubuntu 14.04
Platform: RaspberryPi Mode B version 2 and
version 3
NUT: tested version 2.6.3, 2.7.1
and 2.7.2 (from
2007 Nov 25
2
Nut problems with Centos and Belkin UPS
...0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 34
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xc0
Self Powered
MaxPower 20mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Devices
bInterfaceSubClass 0 No S...
2011 May 30
2
UPS Liebert GXT3 config
...0x00
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 37
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 4
bmAttributes 0x40
(Missing must-be-set bit!)
Self Powered
MaxPower 0mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 0 No Su...