2017 Feb 21
1
[HCL] Powerware PW5125 with driver bcmxcp
...u'd like me to do with it. Let me know if there is anything else you need... -------------- next part -------------- via NUT 2.7.4, FreeBSD 11.0 # upsc ambient.temperature: 42 ambient.temperature.high: 70 battery.charge: 95 battery.charge.restart: 76 battery.charger.status: resting battery.energysave.delay: 0 battery.energysave.load: 0 battery.packs: 1 battery.runtime: 2760 battery.runtime.low: 2 battery.voltage: 52.26 device.mfr: Eaton device.model: PW5125 1500i device.part: 05146632-5501 device.serial: UX475A0xxxxx device.type: ups driver.name: bcmxcp driver.parameter.baud_rate:...
2017 Feb 20
2
[HCL] Powerware PW5125 with driver bcmxcp
This UPS is already listed in the compatibility list. But I wanted to add the instant commands supported by upscmd: ============================ Instant commands supported on UPS [PW5125]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper load.on - Turn on the load immediately outlet.1.load.off - Turn off the load on
2015 Mar 16
0
Roadmap to 2.7.3
On Mar 4, 2015, at 9:04 AM, Charles Lepple wrote: > We only have a few open items that I think should be resolved before releasing 2.7.3. The list grew a bit in the past week, but we'll cover that later. Here is the list: > > * #93: Devices Dumps Library improvements <https://github.com/networkupstools/nut/issues/93> > * #158: Powerware BCMXCP advanced features
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
...port it. > > Thank you, > Bart Can you tell from this output? If not, what should I be looking for to answer your question? [dan at slocum:~] $ upsc ups02 battery.capacity: 9.00 battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.charger.status: resting battery.energysave: no battery.protection: yes battery.runtime: 1941 battery.type: PbAc device.mfr: EATON device.model: Eaton 5PX 2200 device.serial: G091C30079 device.type: ups driver.name: dummy-ups driver.parameter.mode: repeater driver.parameter.pollinterval: 2 driver.parameter.port: ups02 at bast.int.unixathome...
2015 Mar 19
4
Roadmap to 2.7.3
...> what needs to be agreed upon for the new names? > I pushed to the same branch and documented the new vars: input.*.load, input.*.realpower and input.*.power No much need for a hard agreement, more for info... I've rebased and pushed this branch to master. I've also fixed the eaton-energysave branch as per the names pushed in in #158. Note that I've proposed and made an addition for battery.energysave.realpower Just rebased and merged the branch few minutes ago. The rest is good to me too. So is everything good to go from your PoV Charles? thanks for this update and all your work...
2013 Nov 01
3
Merging blzr as blazer (and un-merging voltronic?)
Daniele, Thanks again for your work on both the voltronic and blzr drivers. To get the most exposure to new drivers, what we have typically done in the past is to rename the existing driver as *-old, so that users get the new driver by default when they upgrade (but the old driver is still available if there are regressions). This is how we are incorporating Michal's apcsmart updates. On
2010 Oct 06
1
Model list missing my UPS, here is info for inclusion on the list
...TS: > > EATON Powerware 5130 using UPS cable works. > > lsusb shows: > ID 0463:ffff MGE UPS Systems UPS > > > nkj at grisen:~$ sudo upsc PingvinUPS > battery.capacity: 9.00 > battery.charge: 71 > battery.charge.low: 20 > battery.charge.restart: 0 > battery.energysave: no > battery.protection: yes > battery.runtime: 2449 > battery.type: PbAc > device.mfr: EATON > device.model: 5130 RT 3000 > device.serial: NC302C5031 > device.type: ups > driver.name: usbhid-ups > driver.parameter.pollfreq: 30 > driver.parameter.pollinterval: 2 >...
2014 May 26
2
Resetting replace battery status on Pulsar 1500
...I can't find out how to reset the flag in NUT. I've looked in upsc, upsrw and upscmd but none seem to have a suitable option. The UPS is connected via RS232 and upsc output is as follows.. battery.capacity: 9.00 battery.charge: 100 battery.charge.low: 50 battery.charge.restart: 0 battery.energysave: no battery.protection: yes battery.runtime: 3000 battery.type: PbAc device.mfr: MGE UPS SYSTEMS device.model: Pulsar 1500 device.serial: 1Y3G41223 device.type: ups driver.name: mge-shut driver.parameter.offdelay: 120 driver.parameter.ondelay: 190 driver.parameter.pollfreq: 30 driver.parameter.pol...
2015 Mar 04
5
Roadmap to 2.7.3
We only have a few open items that I think should be resolved before releasing 2.7.3. The list grew a bit in the past week, but we'll cover that later. Here is the list: * #93: Devices Dumps Library improvements <https://github.com/networkupstools/nut/issues/93> * #158: Powerware BCMXCP advanced features <https://github.com/networkupstools/nut/pull/158> * #185: insecure storage
2010 Mar 01
3
NUT with Eaton 9135 6000
Hi Dag 2010/2/28 Dag Atle Nettum <dagatle at innit.no> > Hello > > > > I understand you are the project leader of Nut. > > > > In my company we have a Eaton 9135 6000 UPS, we are running NUT 2.4.1 > (Debian squeeze) > > > > The ups is connected with a USB cable but it reports a temperature of 300 > degredes. > > > > Can I send you
2020 Sep 30
2
reset "replace battery" flag
...hid-ups driver with what nut believes it > sees. I have a feeling that some flag is misinterpreted Sure. Attached. Lionel -------------- next part -------------- battery.capacity: 12.00 battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.charger.status: resting battery.energysave: no battery.protection: yes battery.runtime: 4734 battery.type: PbAc device.mfr: EATON device.model: Eaton 5PX UPS LI R 3000 device.serial: 3C86090469 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.paramete...
2023 Jan 17
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
...0 min_bypass_freq, settable range: 50.0..59.0 No values for battery high/low voltages Using 'guesstimation' (low: 62.400000, high: 90.000000)! setvar(ups.delay.start, 60) setvar: SUCCEED setvar(ups.delay.shutdown, 30) setvar: nothing to do... [ups.delay.shutdown] battery.charge: 100 battery.energysave: no battery.packs: 1 battery.protection: yes battery.runtime: 2820 battery.voltage: 082.0 battery.voltage.high: 90.00 battery.voltage.low: 62.40 battery.voltage.nominal: 72.0 device.model: 3K device.type: ups driver.name: nutdrv_qx driver.parameter.bypass_when_off: disabled driver.parameter.offdel...
2023 Jan 17
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
...0 min_bypass_freq, settable range: 50.0..59.0 No values for battery high/low voltages Using 'guesstimation' (low: 62.400000, high: 90.000000)! setvar(ups.delay.start, 60) setvar: SUCCEED setvar(ups.delay.shutdown, 30) setvar: nothing to do... [ups.delay.shutdown] battery.charge: 100 battery.energysave: no battery.packs: 1 battery.protection: yes battery.runtime: 2820 battery.voltage: 082.0 battery.voltage.high: 90.00 battery.voltage.low: 62.40 battery.voltage.nominal: 72.0 device.model: 3K device.type: ups driver.name: nutdrv_qx driver.parameter.bypass_when_off: disabled driver.parameter.offdel...
2020 Sep 25
2
reset "replace battery" flag
On Thu, Sep 24, 2020 at 06:51:23PM +0300, Manuel Wolfshant wrote: > On 9/21/20 9:47 PM, Lionel Élie Mamane wrote: >> We have a HP R/T 3000 G4 UPS; according to the data returned by the >> usbhid-ups driver, it seems to be a "badge engineered" Eaton 5PX >> UPS LI R 3000. >> We have a stubborn "Replace Battery" alarm that stays (...): >> The
2014 Dec 17
2
EATON 9SX not display battery.charge
...cp uucp 4604 Dec 15 17:19 upsd.conf -rw-r----- 1 uucp uucp 15273 Dec 15 17:14 upsmon.conf # cat /etc/devfs.conf perm ugen1.3 0660 own ugen1.3 root:uucp # cat /etc/devfs.rules [nutusb=10] add path 'usb/1.3.0' group uucp mode 0660 upsc eaton9sx battery.capacity: 5.00 battery.energysave: no battery.protection: battery.type: PbAc device.mfr: EATON device.model: Eaton 9SX 5000i device.serial: G200E36025 device.type: ups driver.flag.maxreport: enabled driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.version: 2....
2023 Jan 15
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
Cheers, One PR waiting to get into 2.8.1 release timeframe is https://github.com/networkupstools/nut/pull/1652 stemming from issue https://github.com/networkupstools/nut/issues/1279 The gist of it is that "battery.voltage" and "battery.charge" were not always reported correctly with nutdrv-qx driver (might be handled better by blazer drivers though), and the overrides
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
...voltage.nominal "72" 12.389358 entering hid_get_value(UPS.PowerSummary.Output.Current) 12.389363 entering lookup_path(UPS.PowerSummary.Output.Current) USB (using usbhid-ups) ---------------------- battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.energysave: no battery.protection: yes battery.runtime: 5400 battery.type: PbAc device.mfr: MGE UPS SYSTEMS device.model: Pulsar Evolution 3000 device.serial: AF3Ennnnn device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.p...
2017 Mar 23
5
Fatal EEPROM fault!
Hello, Sorry if any of this is obvious - I'm new to NUT. NUT via upsc is displaying (edited for length): device.model: Eaton 5P 2200 device.type: ups driver.name: usbhid-ups ups.alarm: Fatal EEPROM fault! ups.status: ALARM OL CHRG ups.test.interval: 604800 ups.test.result: Done and passed driver.version: 2.7.2 driver.version.data: MGE HID 1.33 driver.version.internal: 0.38 Is this possibly
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
...ion: 2.7.4 Installation method: from source tarball UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in October 2013 Here?s the status as reported by upsc: battery.capacity: 9.00 battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.charger.status: floating battery.energysave: no battery.protection: yes battery.runtime: 1032 battery.type: PbAc device.mfr: EATON device.model: Eaton 5PX 2000 device.serial: G098D27047 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchro...
2020 Sep 05
9
ups not being started sat reboot
But runs normally if started. On a rpi4 running an uptodate raspbian buster, how do I set it to auto start at boot time? Thanks. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D.