2009 Jun 09
4
[PATCH] btrfs: fix write_dev_supers
Hi. I got following BUG trace. This is violation of BUG_ON(!buffer_locked(bh)) check on submit_bh() function. In write_dev_supers(), if wait parameter is set and buffer_uptodate() check is negative, submit_bh() is executed and hit above BUG_ON. So I fixed this issue. Thanks. Jun 9 00:41:32 dl580 kernel: ------------[ cut here ]------------ Jun 9 00:41:32 dl580 kernel: kernel BUG at fs/buffer.c:2933! Jun 9 00:41:32 dl580 kernel: invalid opcode: 0000 [#1] SMP Jun 9 00:41:32 dl580 kernel: last sysfs file: /sys/devices/system/cpu/cpu7/cache/index1/sha red_cpu_map Jun 9 00:41:32 dl580 kerne...
2013 May 21
0
semi-OT: flashing the BIOS on an HP dl580 GT, afterward
When last we saw our hero, er, sysadmin, he'd found that the "noarch" BIOS update was, in fact, a self-extracting .exe file, and he'd extracted it. Finally getting the ok to take the system down, the following hilarity (for small values of hilarity) ensued. First, booting off unetbootin to freedos was fine... except it was try to guess which version - freedos + emm386 + himem,
2014 Feb 20
2
HP dl580 g5 RAID management
If this were a Dell RAID, I could use megaraid while the system's running. Does anyone know what I need to use to manage the HP "amart array" RAID? I've got an orange light on a drive, and can't find, googling, whether I can just pull the drive, or if I have to separate it from the RAID, or.... And can't bring the system down to use the firmware interface, not without
2014 Feb 21
1
failed drive on an HP dl580 G5
The hpacucli works... but what isn't clear to me, even with googling, is whether I have to do something from the utility, or whether I can just pull the failed drive out of the hot-swap bay and put another in. I *do* see that I have to re-enable the drive, or rescan it, but right now, I'm concerned about just pulling the dead one out. mark
2011 Aug 17
5
facter-1.6.0 incorrectly identifies hardware node as virtual
I''ve installed facter-1.6.0 and puppet-2.7.3 on a number of SLES 10 hardware nodes (HP DL580) running the Virtuozzo hosting software. Well, facter correctly identifies such a machine as a hardware node ("virtual => openvzhn") but somehow concludes that the hardware node is in fact virtual. ("is_virtual => true") This breaks some rather important logic. If anyone...
2004 Dec 05
3
64bit and 32 bit
Dear all... Currently I am having 5 RAC nodes with Configurations as below : 1. HW = DL580 32 Bit Processor 2. OS = RHAS 2.1 3. OCFS= Latest Version 4. RAC= Oracle9i 9.2.0.5 (32 Bit) Now I am planning to add 2 more Rac Nodes in the existing RAC: 1. HW=Itanium 64 bit processor 2. OS=RHAS 3.0 3. OCFS=Latest Version 4. RAC=Oracle9i 9.2.0.5 (32 bit) Can I...
2015 Oct 07
2
OT hardware issue: HP controller to 3rd party RAID
...hing), as > long as you flash that to be in "IT" (Initiator-Target) mode as they > usually come in IR (Integrated Raid). If the server is PCI-Express v3, > then you'll want a newer card based on the LSI 2308 chip, such as the HP > H221 I mentioned) It's an old box, a DL580 G5. And we didn't get the card with the RAID. I suppose I can single path each RAID from the PERC H800, until budgets open up. mark
2013 Aug 15
2
back to: kernel: do_IRQ: 2.96 No irq handler for vector (irq -1)
I asked here a week or so ago, and referenced an older bug, but haven't seen any comments. Googling, I see others asking about the same. Datum: *every* one I've found is like this: they're all HP DL580's or DL380's, or such. This is being used for heavy-duty scientific computing. Does anyone know if it *will* it seriously affect throughput speed if I turn off irqbalance? It's running 6.4, btw. mark
2009 Jan 06
2
cluster member hangs during reboot
...I put the server into rescue mode and comment out all the filesystems it boots up fine and than I can mount the ocfs2 filesystem manuelly but it cannot do it by itself during reboot... ? msg "EMCPUT MODULE LOADED. OCFS2 USER DLM KERNEL INTERFACE LOADED..." ? ? The server is a HP Proliant DL580 running redhat linux AS 40 update 6 ? Any idea why this node cannot fully reboot and join the cluster?? Any help is highly appreciated. Thanks! -------------- next part -------------- An HTML attachment was scrubbed... URL: http://oss.oracle.com/pipermail/ocfs2-users/attachments/20090106/2...
2013 Sep 05
3
Getting a do_IRQ: xx.xxx No irq handler for vector (irq -1), any ideas?
...for vector (irq -1) do_IRQ: 3.147 No irq handler for vector (irq -1) do_IRQ: 18.117 No irq handler for vector (irq -1) do_IRQ: 3.103 No irq handler for vector (irq -1) do_IRQ: 3.169 No irq handler for vector (irq -1) do_IRQ: 18.201 No irq handler for vector (irq -1) The machine is an HP ProLiant DL580-G5 series with 4x Xeon hexacore processors installed, along with 32G of RAM at this time. I am happy to post more dmesg output if it's of any help. Kernel version is: 2.6.32-358.18.1.el6.x86_64 --- Howard Leadmon
2013 Apr 30
3
flashing a BIOS on an HP server
Hi, folks, Since I've gotten a total of one response in days on the HP forum, maybe the collective mind here has an answer.... As I've mentioned in other posts, we have an HP dl580 g5 that started throwing ECC errors. But wait, it's worse: memory is mirrored.... And the thing is fully populated with 32 DIMMs. I took my best guess, pulled the matching set of DIMMs, and took two off of one of the four riser boards to replace them. I find that the m/b *must* be fully po...
2013 Apr 24
3
DIMM problem
Hey, folks, I've got an HP Proliant DL580 G5 throwing ECC errors. This is annoying, since a) it's all new as of a few months ago, and b) it's *fully* populated. The two things I need to figure out are a) *which* DIMM it is, and b) is it mirrored; if so, which *other* DIMM needs to come out until we get replacements from the OEM. H...
2015 Oct 26
3
semi-OT: HW
Running CentOS 6.7, on an older HP DL580 G5. We've got a Dell 12-bay RAID box plugged into a PERC H800 (aka LSI Liberator) that we put in the HP, and that works fine. We've got a new RAID (a JetStor), and are trying to plug it in. The layout is that the Dell RAID is dual-pathed DAS. Each PERC has two DAS ports. We've got the...
2005 Apr 14
3
CentOS and HP Drivers
I am debating installing CentOS on a new HP DL580 with an MSA1000 SAN. HP offers drivers that are specific to RHEL and will not install on other RH distros i.e. RH 9. Has anyone gotten the HP SupportPack to install under CentOS? Thanks! -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be cle...
2006 Mar 03
1
zfs? page faults
Hi, I have setup an old Compaq Proliant DL580 with 2 xeon @700MHz 2Gb RAM two SmartArray 5300 controllers and 12 drives in an array enclosure. I am running the latest opensolaris update bfu''ed from binaries since I could not build from source. I am controlling the drives with the cpqary3 driver (Solaris 10) from HP. Initially the...
2010 Jun 03
1
Xen 3.1.2 on CentOS 5.5 doesn't see all 4 CPUs
Hello all, I've been digging around on this for a few days and I have not come up with a solution. I have a Compaq ProLiant DL580 (G1, the old tan Compaq) with 4 x 700MHz P-III CPUs and 11GB of memory. I've loaded CentOS 5.5 with Virtualization (Xen) + KVM and patched up to current (full KS packages file list at the end). When it boots, Xen only detects a single CPU as shown in the xm dmesg output (full output and the e...
2009 Nov 23
18
OpenSuSE 11.2 bug, dom0-cpus limit causes xenwatch_cb running 100% and xm command freeze and xend dead
Hi all, I have upgraded a test machine from OpenSuSE 11.1 to 11.2. I have found following bug: the server is a 2x quadcore intel box also 2x4=8cpu If you limit the dom0 cpu with dom0-cpus= [1-7]: - [xenwatch_cb] is running 100% cpu and makes var log entry every 65 sec BUG: soft lockup - CPU#X stuck for 61s! - xm commands not work - xend is dead if set dom0-cpus to 0 or 8: - everything looks
2009 Aug 13
1
Shutdown to single user mode causes SysRq Reset
Hello, I've got a 2 node HP DL580 cluster supported by a Fibrechannel SAN with dual FC cards, dual switches and an HP EVA on the back end.? All SAN disks are multipathed.? Installed software is: Redhat 5.3 ocfs2-2.6.18-128.1.14.el5-1.4.2-1.el5 ocfs2-tools-1.4.2-1.el5 ocfs2console-1.4.2-1.el5 Oracle RAC 11g ASM Oracle RAC 11g Clust...
2009 Jul 19
3
DAHDI Error and poor audio quality
Hello Team I have installed the new DL580 and used the new TE420B to add capacity on our ivr. Before I put new E1?s I decided to first move the old e1 from the old system to this new one but it has errors which not only affect the audio quality, but also cause the asterisk to refuse any call after sometime even though the channels seems up...
2015 Oct 07
0
OT hardware issue: HP controller to 3rd party RAID
On 10/7/2015 2:15 PM, m.roth at 5-cent.us wrote: > It's an old box, a DL580 G5. And we didn't get the card with the RAID. I > suppose I can single path each RAID from the PERC H800, until budgets open > up. wait, you originally said HP SmartArrray P800. Now, its a Dell PERC H800? I'm confused. -- john r pierce, recycling bits in santa cruz