Displaying 20 results from an estimated 517 matches for "cybereality".
2006 Dec 04
2
Cyber Cafe Pro on Linux
Hi,
I'm running an internet cafe using Cyber Cafe Pro software. This software is design soley for Windows platforms. We're constantly experiencing problems with Windows with regards to viruses and stability issues. Recently, we lost all our data and had to re-install.
May you please help us in flawlessly porting this application so that it can run on Linux both on the server and client
2013 Nov 09
2
My samba can't see its own groups! (4.0.9 as solo AD DC)
My samba thinks its own groups don't exist.
Background: I had a samba3 server operating as a NAS with some desktops
joined to the domain. I'm migrating it to samba 4.0.9 as an AD domain.
Users can log in and browse their home share -- but the other shares
aren't working. They're per-project shares set up to allow that
project's group access, and to forcibly make all files
2018 Feb 01
1
testing shutdown: pc not restarting; and "ups unavailable" messages
Executive summary:
I am installing a UPS with NUT on Ubuntu for the first time. I could
follow the instructions up to "testing shutdowns" but on executing the
recommended command the computer shuts down and never comes back on,
contrary to what the instructions suggest.
I am also seeing regular broadcast messages on the console that the UPS
is unavailable (and in the? syslog that
2024 Jan 13
1
Cyber Power LE1000DG UPS
I have a Cyber Power LE1000DG UPS I got from Best Buy this weekend. I plan to use it with a TrueNAS scale system, and it is connected via USB. Vendor link: https://www.cyberpowersystems.com/product/ups/battery-backup/le1000dg/.
TrueNAS has you pick a UPS driver. I could not find any "LE" related models on https://networkupstools.org/stable-hcl.html (which is the list TrueNAS uses). Per
2018 Sep 26
1
[HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
Cyber Power Systems CP600LCD
https://www.cyberpowersystems.com/product/ups/cp600lcd/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS CP600
device.type: ups
driver.name: usbhid-ups
2007 Dec 03
0
Cyber Timer(cybermanager)
Hi all,
Am setting up a internet cyber cafe of roughly 50 or
so boxes running on CentOS 5.0.
Now the question is. Does someone on the list know of
a open source cyber timer/cybermanager which runs on
CentOS(LINUX) and where i can download it? All that am
getting are M$ based.(grrrh).
Thanks.
-------------------------------------------------
David Maina.
Systems/Network Administrator.
PdE-Kenya.
2016 Nov 23
2
[HCL] CyberPower Cyber Power Systems CP685AVR supported by usbhid-ups
It looks like the CyberPower Cyber Power Systems CP685AVR supported by
usbhid-ups has a favorable device dump linked to the Devices Dumps
Library page here:
http://networkupstools.org/ddl/Cyber_Power_Systems/CP685AVR.html
However, it is not listed anywhere on the Hardware Compatibility List
(HCL) page here:
http://networkupstools.org/stable-hcl.html
This appears to be an omission on the HCL
2012 May 28
1
[HCL] Cyber Power Systems CP1000PFCLCD supported by usbhid-ups
Cyber Power Systems CP1000PFCLCD
= upsc output =
attached
= Shutdown results =
I experienced a genuine power outage shortly after setup. The 1 master
system and the 1 slave system both shutdown successfully. The master
shutdown before the slave (*not* a bug report; I may not have this
configured correctly yet). The UPS was not powered off by the master. I
don't know if the UPS
2010 Feb 23
2
NUT with Cyber Power 700 AVR
I recently purchased a Cyber Power 700 AVR UPS. I installed it just fine
and wanted to install NUT to monitor the unit.
I searched the mailing
list and found a similar post. However, the distro used in that post was
different and the unit was slightly different (900 AVR).
My server is
running Debian Lenny. The Cyber Power UPS is connect to one of the serial
ports using the cable that came with
2011 Jan 21
2
Cyber Power USB UPS'.
Greetings:
I'm evaluating two replacements for UPS upgrades to my dept. Because
the CyberPower OP650 has been retired, we are evaluating the
CyberPower600VA and the CyperPower 1000AVRLCD. We will be evaluating
others.
Initial configuration and communications are established via the
usbhid-ups driver, the gambit of tests are all passed with the
exception of one. I seem to be failing
2008 Nov 26
1
Battery Volts shown as 20+ on Cyber Power UPS CP1000AVRLCD
Nut Developers,
I have unsuccessfully tried to solve a problem with the voltage value on my
Cyber Power UPS CP1000AVRLCD. Something is wrong with the battery voltage
calculation. It always reads around 20 volts with that's nuts (pardon the pun).
Right now:
battery.voltage : 20.3
You can take a look for yourself at http://www.3111skyline.com/nutindex.html
Is there a parameter I can check
2018 Sep 26
0
[HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
Cyber Power Systems AVRG750U
https://www.cyberpowersystems.com/product/ups/avrg750u/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 15360
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: AVRG750U
device.serial: <REDACTED>
device.type: ups
2007 Nov 22
4
trouble with Cyber Power System CPS RS232 USB BRIDGE for UPS
Hi
Recently i bought a MicroDoWell BP50, and with it followed a USB 2
serial
converter. When i plug it into my 2.6.19 kernel, dmesg shows
hiddev96: USB HID v1.10 Device [Cyber Power System CPS RS232 USB
BRIDGE for UPS] on usb-0000:00:04.2-2
usbcore: registered new interface driver usbhid
drivers/usb/input/hid-core.c: v2.6:USB HID core driver
So, i figured i should use usbhid-ups,
2018 Apr 25
2
Wanted: WebRTC tutorial
On 04/24/2018 09:08 AM, Matt Fredrickson wrote:
> On Tue, Apr 24, 2018 at 10:54 AM, Bruce Ferrell <bferrell at baywinds.org> wrote:
>> A while back (last year maybe?), there was a Digium blog post on setting up
>> WebRTC.
>>
>> I was never able to get that working.
>>
>> I was working with Asterisk 15 on a RHEL derived distro and had no idea of
>>
2024 Mar 09
0
Cyber Power System CP1500 AVR UPS: changing battery.charge.low value
Hi Charles,
The posting at
https://github.com/networkupstools/nut/issues/432#issuecomment-405371395
references ups.delay.start and suggests setting it to -1.
upsrw -l pve1 at localhost listed this as modifiable but any attempt at
modifying the value failed. I used the *override.ups.delay.start = -1* in
nut.conf and this is now being reported.
Two observations are that once a variable setting
2007 Mar 20
8
Is there any performance problem with hard links in ZFS?
Is there any performance problem with hard links in ZFS?
I have a large storage. There will be near 50000 hard links for every file. Is it ok for ZFS? May be some problems with snapshots(every 30 minutes there will be a snapshot creating)? What about difference in speed while working with 50000 hardlinks or 50000 different files?
ps: It would be very useful if you give me some links about
2013 Nov 22
0
[HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver
CyberPower Battery Backup with Surge Protection, model LE825G
Appears to function properly with the driver listed on the HCL for the
Cyber Power Systems ups 2 685AVR USB (usbhid-ups).
Tested with shutdown mode "UPS Goes On Battery" with a 5 second timer
and the system successfully shutdown as expected.
upsc output:
upsc ups
battery.charge: 100
battery.charge.low: 10
2016 Nov 24
0
[HCL] CyberPower Cyber Power Systems CP685AVR supported by usbhid-ups
[please use Reply-All - this list does not modify the reply-to header]
> On Nov 23, 2016, at 10:30 AM, Craig STCR <craig.stcr1 at gmail.com> wrote:
>
> It looks like the CyberPower Cyber Power Systems CP685AVR supported by
> usbhid-ups has a favorable device dump linked to the Devices Dumps
> Library page here:
>
>
2017 Sep 13
0
[HCL] Cyber Power UPS LX1500GU supported by driver usbhid-ups
Cyber Power UPS Model LX1500GU
*upsc output:*
root at freenas:~ # upsc ups at localhost
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 5670
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: LX1500GU
device.serial: QAKGP2000252
device.type: ups
driver.name:
2024 Mar 08
1
Cyber Power System CP1500 AVR UPS: changing battery.charge.low value
On Mon, 4 Mar 2024, Alan C. Bonnici via Nut-upsuser wrote:
> Platform: Proxmox VE 8.1.4
> NUT version: Network UPS Tools upsstats 2.8.0
>
> I configured Proxmox and I can pull up the UPS stats.
> Typing in `upsrw -l cyberpower at localhost` I get the following:
>
> [battery.charge.low]
> Remaining battery level when UPS switches to LB (percent)
> Type: STRING
>