search for: chargers

Displaying 20 results from an estimated 153 matches for "chargers".

Did you mean: charger
2015 Mar 25
2
On ups.status CHRG/DISCHRG Vs battery.charger.status
Hi NUT developers, part of the 2.7.3 release, we are about to merge the below branch / PR for the bcmxcp drivers family: https://github.com/networkupstools/nut/pull/158 https://github.com/networkupstools/nut/tree/pull_158_bcmxcp_rebased It has introduced the battery.charger.status variable, which is something I wanted to implement since around 2007. However, while considering a similar
2015 Mar 30
1
On ups.status CHRG/DISCHRG Vs battery.charger.status
Hi Charles, 2015-03-29 0:44 GMT+01:00 Charles Lepple <clepple at gmail.com>: > On Mar 25, 2015, at 4:11 AM, Arnaud Quette <arnaud.quette at gmail.com> > wrote: > > > 1) Keep the legacy CHRG / DISCHRG status bits for ups.status, along with > the complementary ones for battery.charger.status. And advocate (document) > for the use of / switch to the latter, that is
2015 Mar 28
0
On ups.status CHRG/DISCHRG Vs battery.charger.status
On Mar 25, 2015, at 4:11 AM, Arnaud Quette <arnaud.quette at gmail.com> wrote: > 1) Keep the legacy CHRG / DISCHRG status bits for ups.status, along with the complementary ones for battery.charger.status. And advocate (document) for the use of / switch to the latter, that is more suitable for publishing such information. All that with an impact on all the NUT driver, and a transition
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi, This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status. Details of our installation are: OS: Debian 6 NUT version: 2.7.4 Installation method: from source tarball UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in
2011 May 04
0
charger does not work?
My netbook (http://www.laptopspark.com) was charging fine when I was first on it. I accidently pulled it too far but the charger didn't un-attatch from Sony Vaio EA3S1E/L Intel Core i3 370M 2.4GHz 500GB HDD 4GB RAM 14.1" WXGA TFT Laptop (http://www.laptopspark.com/products/Sony-Vaio-EA3S1EL-Intel-Core-i3-370M-24GHz-500GB-HDD-4GB-RAM-141-WXGA-TFT-Laptop-laptop-290.html) or plug. I checked
2003 Apr 03
0
New Coin Operated Mobile Phone Charger - Seeking Overseas Distributors
ProductPublic Mobile Phone Multi-charger (With/Without Coin Module) Functions1. Accept coins. 2. Allows conversation while charging. 2. 10 travel charger plugs for most models. 3. Light box advertising. 4. UV phone sanitizing InputAC 110 - 250V 50~60Hz Output< 12 V 1C 5 A x 10 Measurement29 cm x 20 cm x 51.6 cm Net Weight5 kg Contacthttp://www.YukiCharger.com sales@YukiCharger.com
2014 Feb 19
3
Logic problem in NUT with upscode2 driver
...ow discharged. But they were NOT discharged and easily kept the servers up and online. The UPS reports a battery max voltage of 56.4 and minimum voltage of 40 and nominal voltage of 48 (this is obviously for a given bank) Now I do not know if OTHER upses that require upscode2 have battery chargers that sense battery voltage like this, and that shut off. If I disconnect the battery pack for a second and plug it back in, the battery charger sees the loss of battery voltage and turns back on, so it's obvious the charger is sensing battery voltage. I am guessing the upscode2 driver is as...
2024 Nov 13
2
Eaton 5PX 3rd party batteries
resending, sorry, I mangled the list address. On Tue, Nov 12, 2024, at 11:49 PM, Harlan Stenn wrote: > - put each battery on a charger for several hours Do you have a recommendation for a battery charger? Or a list of features to look for? > Anyway, when I have a set of replacement new batteries, I then: > > - put each battery on a charger for several hours > - rotating thru
2008 Apr 01
1
Incorrect battery status on MGE Pulsar M 3000
Hello! We have two upses: MGE Pulsar M 3000 and MGE Pulsar EXtreme 3200C. They connect to server by USB. EXtreme works good with usbhid-ups (nut 2.2.1) and newhidups (nut 2.0.5). But Pulsar M doesn't want to work with usbhid-ups. - my ups.conf: [extreme] driver = usbhid-ups port = auto product = "EXtreme" [pulsar] driver = usbhid-ups port =
2011 Jan 04
1
isolinux, extlinux and accented characters
Hello, First of all, thanks very much for this piece of software, it's working like a charm. I'm using it to boot a Linux distro I'm working on. What I want to deal with is the display of accented characters in ISOLINUX. First, I set EXTLINUX up to boot an ext2-formatted USB stick. No problem so far. I wrote a config file ordering to load a font (lat-9w) to display french
2016 Oct 30
2
Power Cut
Thank you for your reply. You are correct and the ups is present there but the battery charger can no longer bear power cuts more than two hours so I need some means to distinguish frequent power cuts there among the system logs. On Sun, Oct 30, 2016 at 12:02 AM, Eero Volotinen <eero.volotinen at iki.fi> wrote: > you could use smart ups and connect information from it to system, so it
2016 Oct 30
7
Power Cut
Dear All I am using a centos server for cdr billing and mediation device on a remote network. I am experiencing problem that I am suspicious it comes from main supply power cut at the remote site. The power supply to the remote site comes from battery charger that will be automatically switched in circuit under main supply power cut but cannot provide adequate power for more than 2 hours . I am
2008 Jan 15
1
How to lower float charge voltage of an APC Smart UPS
Dear Sir, Please tell me if u have any method to increase the charging current of APC smart 1000/1400VA with and without external battery bank option. I am using externally 40 and 80 Amp lead acid batteries but charging time is too long. Please help me ASAP. Regards, Afzaal Ahmad UPS Engineer afzaal.ahmad at sbp.org.pk -------------- next part -------------- An HTML
2019 Jun 17
2
Monitoring for an alarm
I found one of UPS has a ups.alarm : Battery charger fail! Internal UPS fault! Is there a way to monitor for this kind of failure? In upsmon I did not find and event type for alarms like this... Thanks Adam Pribyl
2018 May 25
1
[HCL] IBM 1500VA/1000W Tower HV UPS supported by usbhid-ups
Hi I would like to be able to use this UPS with NUT please ? Product id = 53962KX Network UPS Tools - Generic HID driver 0.38 (2.7.2) USB communication driver 0.32 0.000000 debug level is '2' 0.002761 upsdrv_initups... 0.014996 Checking device (03F0/0024) (001/005) 0.032670 - VendorID: 03f0 0.032790 - ProductID: 0024 0.032955 - Manufacturer:
2004 Sep 09
3
Store data from call to database
Hi, I use asterisk for a phone quiz game. I need to store data in a database (MySql, postgres) : telephone number, name (voice), ... and of course the answers at the quetions. What's the best way to store my data ? - script with system() command ? - AGI script - CDR - others ... Thanks Jerome Vous manquez d?espace pour stocker vos mails ? Yahoo! Mail vous offre
2016 Oct 30
3
Power Cut
But the site is far remote and having alert on battery exhaustion can no longer help . As I said before , I am suspicious if it comes from frequent power cuts so seeking some means to distinguish it among the system logs. Thank you in advance On Sun, Oct 30, 2016 at 12:08 AM, Mike Mohr <akihana at gmail.com> wrote: > If your battery backup can handle 2 hours of runtime then it almost
2007 Nov 10
9
problème de téléchargement
salut Alex, je ne peut pas télécharger wxruby-1.9.2 avec rubygems. J''avait wxruby-1.9.0, mais j''ai fait une restauration complète de mon pc hier. J''ai la version 0.9.4 de ruby gems. J''ai un message d''erreur <openURI::HTTPerror> quand je veut installer wxruby-1.9.2. merci _______________________________________________ wxruby-users mailing list
2007 Apr 14
7
=question sur wxruby2
Bonjour, je voulais savoir si wxruby2 est intégré à l''interpréteur ruby? Que veut dire $0 ? merci Sebastien _______________________________________________ wxruby-users mailing list wxruby-users@rubyforge.org http://rubyforge.org/mailman/listinfo/wxruby-users
2020 Nov 01
1
ups.test.result meaning
> > > > battery.voltage: 16.0 > At that voltage, 5 of the 12 cells are shorted > > output.voltage: 138.0 > too high by about 15 volts > > Wow! That battery is beyond toasted, shoulda been replaced months ago. > And the output voltage is a bit much if its truthfull. > Thanks for the response Gene! I've ordered a replacement unit. I'm not sure about the