Displaying 20 results from an estimated 62 matches for "bnt".
Did you mean:
bit
2006 Dec 11
2
howto setup BNT-1500AP on gentoo
Good afternoon. I try to put nut on gentoo. Has executed installation
by a standard command emerge nut. All has passed successfully. I use
UPS POWERCOM BNT-1500AP. It is connected to serial port 1, i.e. for my
system it/dev/tts/0. In/etc/nut/ups.conf
[powercom]
driver = powercom
port = /dev/tts/0
desc = "PowerCom BNT-1500AP on IP-PBX"
modelname = "BNT-1500AP"
linevoltage = 230
type = KIN1500AP
also trying:
[powercom]
driver = pow...
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
....com>
> >
> > > Hi!
> > > Normally nut was just worked and worked for me!
> > > Not this time though!
> > >
> > > Distro is Gentoo withe latest nut-2.6.0 emerged today.
> > > Linux kernel version is 2.6.36
> > > UPS is PowerCom BNT2000AT
> > > "Driver" is powercom
> > > ups.conf looks like this! Okay so APC1 is not and APC!
> > >
> > > [APC1]
> > >
> > > driver = powercom
> > > type = BNT
> > > port = /dev/ttyS1
> > &...
2007 Nov 06
1
BNT-1000AP
Hi guys,
We've got a BNT-1000AP (powercom) BlackKnight UPS that works with the
KIN1500AP model in the powercom driver. Well, almost. It seems the
input frequency and the battery charge is swapped around:
# upsc blackknight at localhost
battery.charge: 46.5
driver.name: powercom
driver.parameter.manufacturer: BlackKnig...
2010 Jul 02
0
Powercom driver patch
...KIN" and then
interprets raw data incorrectly. The same problem was reported by
other Powercom users on the official support forum (
http://forum.pcm.ru ).
I suppose the problem concerns models with serial-over-usb connection
implemented via cypress_m8 chip (ID 0d9f:0002), e.g. IMD-865AP USB,
BNT-1000AP USB, etc. (these are on sale everywhere in Russia). The
thing is that such UPS sends raw_data[UPSVERSION]==0xFF like
"Imperial" series and simultaneously raw_data[MODELNAME]==0x4B like
"KING" series (the explanation is proposed here -
http://forum.pcm.ru/viewtopic.php?p=3...
2011 Jan 13
0
[NUT]updated powercom driver for powercom BNT-500AP
...for many devices based on linux
> server.
> In field test, we reached the power shutdown problem which may cause the
> crack of linux file system.
> I search the solution and find NUT project and i'm very glad that NUT
> support Powercom UPS Products.
>
> Nowadays Powercom BNT-500AP is the cheapest model with serial port In South
> Korea, so i buy it for test.
> while I'm testing it with NUT but it isn't easy.
>
> I checked the source file and found that there wasn't code for BNT-500AP.
> BNT-500AP had the different model code(0x4b, it's KI...
2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
Hello all.
Try this driver (for nut 2.2.0). See attach.
- Trust, KP625AP, Egys models stay as it was
- add Powercom's Black Knight Pro model support ( BNT-400/500/600/800/801/1000/1200/1500/2000AP
220-240V )
- add Powercom's King Pro model support (
KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V)
- add Powercom's Imperial model support ( IMP-xxxAP, IMD-xxxAP )
Only for BNT/KIN/IMP/IMD:
power and linevoltage...
2011 Oct 04
2
PowerCOM BNT-800AP (0d9f:0004)
...t it work but haven't luck.
I'm using NUT 2.6.0-1 under Windows XP with libusb driver installed
(USB\VID_0D9F&PID_0004&REV_0001).
I had tryed all options with such config:
*PWCOM]
driver = usbhid-ups
port = auto
vendorid = 0d9f
desc = "Powercom BNT-800AP"
type=BNT*
*
*Here is output from CMD:*
c:\Program Files (x86)\NUT\bin>usbhid-ups.exe -DDDDD -a PWCOM
Network UPS Tools - Generic HID driver 0.35 (2.6.1-3057:3116M)
USB communication driver 0.31
0.000000 send_to_all: SETINFO driver.parameter.port "auto"
0.00...
2013 May 01
1
Powercom BNT-1500AP serial config
Hey all,
Finally got around to hooking up my Powercom BNT-1500AP to nut. It's the
old serial interface.
Connects okay and gets most information, but a couple of data are way off.
Any config recommendations or upgrade recommended? I've played with
config a little, but no hits yet.
Details:
NUT version 2.4.3
ups.conf:
[ups]
driver =...
2005 Jul 06
0
Powercom BNT-1500AP
Hey all,
Does anybody know there is a full working setup for the PowerCom
BNT-1500AP. I got some stuff working with the Powercom driver and the
type set to "KIN1500AP". But it seems that there is still missing
usablity. I was wondering if anybody found any better configs?
---- excerpt of ups.conf
[AVR1500]
driver = powercom
port = /dev/ttyS0...
2006 Apr 21
1
Powercom BNT-1200AP
Hello
I have UPS Powercom Black Knight Pro 1200 (BNT-1200AP)
I try to use nut, but powercom driver not understand my model
Ok, i try to use type KIN1500AP and it's work
But powercom driver can't set UPS's shutdown delay time
Also i have powercom's original program (upsmon), and this program can do it
What can i do for help to add thi...
2006 Jul 08
0
Powercom BNT-600AP and NUT (powercom driver)
Hello,
I'm new there. I bought an UPS Powercom BNT-600AP. It's compatible
in NUT with driver powercom and protocol type KIN1500AP.
But I have a simple problem: the 'upsc' shows wrong values in
battery.charge (maybe in other rows also /ups.load, voltages?/) - if
battery is 100% charged it shows only 92.6% or 93.0%.
I thing I have wrong v...
2017 Apr 26
0
Powercom BNT-2000AP(USB)
Hello all!
Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent three last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2.
# dmesg|grep -i powercom
ugen0.3: <POWERCOM Co.,LTD> at usbus0
uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, a...
2009 Jul 27
1
Powercom BNT-1000CS
Hello. I have recently purchased a Powercom BNT-1000CS(Black Knight CS).
I am new to NUT(and am not a programmer), but I have noticed that this
model does not work with NUT. I am willing to provide details about this
UPS for anyone who would like to add support for it(i dont know how to
get much info though, so you'll have to tell me how...
2012 Nov 13
1
PowerCom BNT-600AP on ubuntu 12.04.1 AMD64
Hello people,
I use a BNT-600AP from PowerCom, and on driver loading (nut service
start) the UPS goes off so I cannot use nut as service as the computer
goes off with the UPS.
When the computer is not using the UPS, but still connected, I see that
the UPS goes off for a very short time, does battery check and goes on
a...
2010 Feb 04
0
Powercom BNT-800AP
...port it as 0V. I have
no idea how to even special-case the screwy input/output-swapping
behavior...
./powercom -a ups0 -DDD
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.1-2308)
0.000000 debug level is '3'
0.001406 Flow control disable
0.150003 Detected: BNT-other-500AP , 120V
0.153986 Values of arguments:
0.154001 manufacturer : 'PowerCom'
0.154009 model name : 'BNT-other-500AP'
0.154015 serial number : 'Unknown'
0.154022 line voltage : '120...
2017 Apr 30
0
Powercom BNT-2000AP(USB)
On April 28, 2017 9:11:59 AM GMT+03:00, "????????? ?????????" <vtk-alexb at mail.ru> wrote:
>Hello all!
>
>Some days ago we received new UPS?Powercom BNT-2000AP with USB
>interface to replace an old staff and I've spent four last days trying
>to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2.
>
># dmesg|grep -i powercom
>ugen0.3: <POWERCOM Co.,LTD> at usbus0
>uhid0: <POWERCOM Co.,LTD HID UPS Battery, clas...
2006 Dec 22
1
Powercom BNT-1200AP driver
Hello.
What about driver for my UPS?
I have changed the powercom driver for myself, but I have made it not absolutely correctly. However, somehow this driver works.
Now i have protocol spec for powercom BNT series and attach it to this email.
It can be interesting to authors?
--
? ?????????, ??????? ???????
mailto:alex@reutman.ru
JID: alex@reutman.ru
ICQ: 5052225
-------------- next part --------------
******************************************************************************
* COMM ---Proto...
2005 Aug 06
0
Driver for Ultra UPS BNT-1000AP
Hi I purchased an Ultra 1000VA UPS
(http://www.ultraproducts.com/product_details.php?cPath=35&pPath=154&productID=154)
I am trying to use nut with it (I am using gentoo
linux) but can't find the proper driver. The numbers
on the back suggest it might be similar to Black
Knight Pro BNT-1000AP from Powercom
(http://www.powercom-usa.com/ProductDetail.asp?ID=8974).
So I tried the powercom and fentonups drivers as
suggested in the nut compatibility list.
I am getting the following errors:
localhost ~ # /etc/init.d/upsd restart
* Stopping upsd ......
2013 Jun 08
0
several problems with Powercom BNT-500AP
On Jun 5, 2013, at 11:49 AM, M?rti?? Pu??tis wrote:
> Driver debug output attached.
The debug output looks normal (many devices do not implement the interrupt pipe; hence, the timeouts). Unfortunately, we might need the log over a longer period of time, including your observations as to when various events occurred (such as transitions to battery).
--
Charles Lepple
clepple at gmail
2013 Apr 28
0
PowerCOM BNT-1000AP HID instant commands patch
Hello,
Got PowerCOM BNT-1000AP, usb id 0d9f:00a6, firmware FW4.A6
nut 2.4.3 on debian stable shows only two instant commands:
beeper.toggle - Toggle the UPS beeper -- not working
test.battery.start.quick - Start a quick battery test -- works ok.
No load and shutdown commands.