Displaying 9 results from an estimated 9 matches for "blazer_vendor".
2015 Dec 11
0
need help for shutdown (windows)
...t reply
   0.437523     Status read 3 failed
   0.437523     Trying mustek protocol...
   0.765652     blazer_status: non numerical value [--.-]
   0.781512     Status read in 1 tries
   0.781512     Supported UPS detected with mustek protocol
   1.000347     Ratings read in 1 tries
   1.141017     blazer_vendor: short reply
   1.141017     Vendor information read 1 failed
   1.281643     blazer_vendor: short reply
   1.281643     Vendor information read 2 failed
   1.422270     blazer_vendor: short reply
   1.422270     Vendor information read 3 failed
   1.437881     Vendor information unavailable
   1.4...
2014 Nov 05
1
blazer_usb disconnects
...: SETINFO input.current.nominal "3.0"
   0.884033    send_to_all: SETINFO battery.voltage.nominal "12.0"
   0.884085    send_to_all: SETINFO input.frequency.nominal "50"
   0.884131    Ratings read in 1 tries
   0.885878    send: I
   0.947886    read: I
   0.947967    blazer_vendor: short reply
   0.948010    Vendor information read 1 failed
   0.949884    send: I
   1.011887    read: I
   1.011965    blazer_vendor: short reply
   1.012009    Vendor information read 2 failed
   1.013878    send: I
   1.075811    read: I
   1.075888    blazer_vendor: short reply
   1.075930...
2010 Dec 29
2
Again me :)
Dears,
I finally resolve my problem, I just make symbolic link:
[test at box var/run/]# ln -s -T /var/state/ups/ nut
Now I finally got services online:
# /sbin/service ups start
Starting UPS driver controller:                            [  OK  ]
Starting upsd:                                             [  OK  ]
Starting UPS monitor (master):                             [  OK  ]
BUT, on upsc I
2011 Sep 28
0
[BUG] nut 2.4.3+: UPS EP-1K: Firmware fault: USB-Interface crashes with nut.org monitoring if driver polling time <15 sec
...send_to_all: SETINFO input.current.nominal "5.0"
    0.758431	send_to_all: SETINFO battery.voltage.nominal "24.0"
    0.758450	send_to_all: SETINFO input.frequency.nominal "50"
    0.758463	Ratings read in 1 tries
    0.759118	send: I
    0.822314	read: I
    0.822349	blazer_vendor: short reply
    0.822362	Vendor information read 1 failed
    0.822988	send: I
    0.886255	read: I
    0.886292	blazer_vendor: short reply
    0.886305	Vendor information read 2 failed
    0.886979	send: I
    0.950253	read: I
    0.950346	blazer_vendor: short reply
    0.950359	Vendor informatio...
2013 Nov 22
1
nutdrv_qx does not support UPS, blazer_ups does
...es
   2.549152     Supported UPS detected with megatec protocol
   2.549217     send: F
   3.138723     received 46 (46)
   3.138794     read: #230.0 003 24.00 50.0
   3.138902     Ratings read in 1 tries
   3.138970     send: I
   3.640739     received 6 (6)
   3.640809     read: #
   3.640870     blazer_vendor: short reply
   3.640930     Vendor information read 1 failed
   3.640990     send: I
   4.143756     received 6 (6)
   4.143825     read: #
   4.143883     blazer_vendor: short reply
   4.143947     Vendor information read 2 failed
   4.144026     send: I
   4.646773     received 6 (6)
   4.646843...
2011 May 01
2
nut problem on boot/restart
...inal "3.0"? ?0.755488	send_to_all: SETINFO battery.voltage.nominal "12.0"? ?0.755497	send_to_all: SETINFO input.frequency.nominal "50"? ?0.755510	Ratings read in 1 tries? ?0.756084	send: I? ?1.756636	read: could not claim interface 0: Device or resource busy? ?1.756660	blazer_vendor: short reply? ?1.756668	Vendor information read 1 failed? ?1.757836	send: I? ?2.758276	read: could not claim interface 0: Device or resource busy? ?2.758298	blazer_vendor: short reply? ?2.758305	Vendor information read 2 failed? ?2.758964	send: I? ?3.760021	read: could not claim interface 0: Device...
2017 Jun 09
2
Help with Elite 800VA usb UPS
Use the name from ups.conf in front of "@localhost".
?The re?sult is quite different ;)
root at artu:~# upsc Elit at artu
Init SSL without certificate database
Error: Driver not connected
> What if you try nutdrv_qx without specifying megatec? (It should
> autodetect.)
>
?Here is the result:
?
 root at artu:~# upsdrvctl start
Network UPS Tools - UPS driver controller
2017 Jun 10
2
Help with Elite 800VA usb UPS
...1.396380     read: #220.0 000 012.0 50.0
   1.396386     blazer_rating: short reply
   1.396392     Rating read 3 failed
   1.396403     Rating information unavailable
   1.396411     send: I
   1.591274     received 38 (35)
   1.591622     read: #                           TR00094S
   1.591816     blazer_vendor: short reply
   1.591925     Vendor information read 1 failed
   1.591938     send: I
   1.785267     received 38 (35)
   1.785641     read: #                           TR00094S
   1.785879     blazer_vendor: short reply
   1.786077     Vendor information read 2 failed
   1.786275     send: I
   1....
2009 Mar 17
2
blazer_usb - short reply
......
Checking device (0000/0000) (001/001)
- VendorID: 0000
- ProductID: 0000
- Manufacturer: Linux 2.6.18-92.1.22.el5.centos.plus ehci_hcd
- Product: EHCI Host Controller
- Serial Number: 0000:00:03.2
- Bus: 001
Trying to match device
Device does not match - skipping
No appropriate HID device found
blazer_vendor: short reply
Vendor information read 3 failed
Vendor information unavailable
Battery runtime will not be calculated (runtimecal not set)
send_to_all: SETINFO ups.delay.start "180"
send_to_all: SETINFO ups.delay.shutdown "30"
send_to_all: ADDCMD beeper.toggle
send_to_all: ADDCMD...