Displaying 9 results from an estimated 9 matches for "blazer_vendor".
2015 Dec 11
0
need help for shutdown (windows)
...t reply
0.437523 Status read 3 failed
0.437523 Trying mustek protocol...
0.765652 blazer_status: non numerical value [--.-]
0.781512 Status read in 1 tries
0.781512 Supported UPS detected with mustek protocol
1.000347 Ratings read in 1 tries
1.141017 blazer_vendor: short reply
1.141017 Vendor information read 1 failed
1.281643 blazer_vendor: short reply
1.281643 Vendor information read 2 failed
1.422270 blazer_vendor: short reply
1.422270 Vendor information read 3 failed
1.437881 Vendor information unavailable
1.4...
2014 Nov 05
1
blazer_usb disconnects
...: SETINFO input.current.nominal "3.0"
0.884033 send_to_all: SETINFO battery.voltage.nominal "12.0"
0.884085 send_to_all: SETINFO input.frequency.nominal "50"
0.884131 Ratings read in 1 tries
0.885878 send: I
0.947886 read: I
0.947967 blazer_vendor: short reply
0.948010 Vendor information read 1 failed
0.949884 send: I
1.011887 read: I
1.011965 blazer_vendor: short reply
1.012009 Vendor information read 2 failed
1.013878 send: I
1.075811 read: I
1.075888 blazer_vendor: short reply
1.075930...
2010 Dec 29
2
Again me :)
Dears,
I finally resolve my problem, I just make symbolic link:
[test at box var/run/]# ln -s -T /var/state/ups/ nut
Now I finally got services online:
# /sbin/service ups start
Starting UPS driver controller: [ OK ]
Starting upsd: [ OK ]
Starting UPS monitor (master): [ OK ]
BUT, on upsc I
2011 Sep 28
0
[BUG] nut 2.4.3+: UPS EP-1K: Firmware fault: USB-Interface crashes with nut.org monitoring if driver polling time <15 sec
...send_to_all: SETINFO input.current.nominal "5.0"
0.758431 send_to_all: SETINFO battery.voltage.nominal "24.0"
0.758450 send_to_all: SETINFO input.frequency.nominal "50"
0.758463 Ratings read in 1 tries
0.759118 send: I
0.822314 read: I
0.822349 blazer_vendor: short reply
0.822362 Vendor information read 1 failed
0.822988 send: I
0.886255 read: I
0.886292 blazer_vendor: short reply
0.886305 Vendor information read 2 failed
0.886979 send: I
0.950253 read: I
0.950346 blazer_vendor: short reply
0.950359 Vendor informatio...
2013 Nov 22
1
nutdrv_qx does not support UPS, blazer_ups does
...es
2.549152 Supported UPS detected with megatec protocol
2.549217 send: F
3.138723 received 46 (46)
3.138794 read: #230.0 003 24.00 50.0
3.138902 Ratings read in 1 tries
3.138970 send: I
3.640739 received 6 (6)
3.640809 read: #
3.640870 blazer_vendor: short reply
3.640930 Vendor information read 1 failed
3.640990 send: I
4.143756 received 6 (6)
4.143825 read: #
4.143883 blazer_vendor: short reply
4.143947 Vendor information read 2 failed
4.144026 send: I
4.646773 received 6 (6)
4.646843...
2011 May 01
2
nut problem on boot/restart
...inal "3.0"? ?0.755488 send_to_all: SETINFO battery.voltage.nominal "12.0"? ?0.755497 send_to_all: SETINFO input.frequency.nominal "50"? ?0.755510 Ratings read in 1 tries? ?0.756084 send: I? ?1.756636 read: could not claim interface 0: Device or resource busy? ?1.756660 blazer_vendor: short reply? ?1.756668 Vendor information read 1 failed? ?1.757836 send: I? ?2.758276 read: could not claim interface 0: Device or resource busy? ?2.758298 blazer_vendor: short reply? ?2.758305 Vendor information read 2 failed? ?2.758964 send: I? ?3.760021 read: could not claim interface 0: Device...
2017 Jun 09
2
Help with Elite 800VA usb UPS
Use the name from ups.conf in front of "@localhost".
?The re?sult is quite different ;)
root at artu:~# upsc Elit at artu
Init SSL without certificate database
Error: Driver not connected
> What if you try nutdrv_qx without specifying megatec? (It should
> autodetect.)
>
?Here is the result:
?
root at artu:~# upsdrvctl start
Network UPS Tools - UPS driver controller
2017 Jun 10
2
Help with Elite 800VA usb UPS
...1.396380 read: #220.0 000 012.0 50.0
1.396386 blazer_rating: short reply
1.396392 Rating read 3 failed
1.396403 Rating information unavailable
1.396411 send: I
1.591274 received 38 (35)
1.591622 read: # TR00094S
1.591816 blazer_vendor: short reply
1.591925 Vendor information read 1 failed
1.591938 send: I
1.785267 received 38 (35)
1.785641 read: # TR00094S
1.785879 blazer_vendor: short reply
1.786077 Vendor information read 2 failed
1.786275 send: I
1....
2009 Mar 17
2
blazer_usb - short reply
......
Checking device (0000/0000) (001/001)
- VendorID: 0000
- ProductID: 0000
- Manufacturer: Linux 2.6.18-92.1.22.el5.centos.plus ehci_hcd
- Product: EHCI Host Controller
- Serial Number: 0000:00:03.2
- Bus: 001
Trying to match device
Device does not match - skipping
No appropriate HID device found
blazer_vendor: short reply
Vendor information read 3 failed
Vendor information unavailable
Battery runtime will not be calculated (runtimecal not set)
send_to_all: SETINFO ups.delay.start "180"
send_to_all: SETINFO ups.delay.shutdown "30"
send_to_all: ADDCMD beeper.toggle
send_to_all: ADDCMD...