Displaying 6 results from an estimated 6 matches for "400va".
Did you mean:
400a
2009 Jul 15
1
How to connect Trust UPS Energy Protector 400VA with nut
Hello list,
I have been trying to figure out the whole day how I can connect our old
Trust UPS Energy Protector 400VA with nut. But I have not made any
progress yet and the worst is: I have no idea where to start although I read
the documentation and search the web.
My first problem is how to find out which driver I should take because
this UPS is not in the compatibility list. The second issue is that it
seems...
2005 Jul 24
0
Mustek 400va + NUT 2.0.1 shutdown problem
I've installed everything from sources (NUT 2.0.1)
on freebsd 5.4 and it detects the ups, it tells me
about the voltages etc.
When the battery charge reaches certain level it
tells me that the battery is low and the system
will shutdown but nothing happenes.
In logs I can only find:
upsmon[386]: Executing automatic power-fail
shutdown
upsmon[384]: Unable to call shutdown command
2005 May 31
10
UPS rating for SOHO asterisk box
...T, but I think this is of possible interest to many of you,
I need to get a UPS for my asterisk box. They are rated in VA but I
can't quite figure out how that converts to real life.
I have a PIII-800 box with two X100P and one TDM400P plus graphics
adapter, an IDE hard drive etc. Will a small 400VA box be enough for
this?
tia
2012 Jun 09
3
[HCL] REDi/Centralion Blazer 600 VA (BLAZER600c) supported by blazer_ser
...interactive
----------cut here----------
I have also run `upsmon -c fsd`, which powers off the server
and after 30 seconds powers off the UPS, but the UPS does *not* start up
automatically afterwards. This is the only problem I had so far
The report above should apply to:
* REDi/Centralion Blazer 400VA
* REDi/Centralion Blazer 600VA
* REDi/Centralion Blazer 800VA
[ since these three are the same UPS with different batteries ]
and might also apply to the other REDi/Centralion Blazer UPSes
If you would like any more information, please tell me
--
Marius Gavrilescu
(etc) They laughed at Einstein....
2008 Nov 06
0
Is usbhid-ups compatible with APC Back-UPS ES 550VA and 700VA devices?
...ions only the "APC Back-UPS ES/CyberFort
350" as compatible and does not give more information about the full
APC/MGE family devices. Also, I'm not sure that an APC Back-UPS ES 550VA
or its equivalent 700VA is the same device as the described Back-UPS ES.
For instance, APC Back-UPS ES 400VA doesn't even have an usb port to
communicate with the pc. It becomes hard to know if all such devices on
the market are nut compatible.
Thanks for your help.
2012 Nov 20
2
[PATCH][RFC] OpenUPS driver
...t;ups" "5" "Rhino 20.0" "20000VA" "rhino"
+"Minibox" "ups" "5" "openUPS Intelligent UPS" "USB port" "usbhid-ups"
+
"Mustek" "ups" "2" "Powermust" "400VA Plus" "blazer_ser"
"Mustek" "ups" "2" "Powermust" "600VA Plus" "blazer_ser"
"Mustek" "ups" "2" "Powermust" "800VA Pro" "blazer_ser"
Index: drivers/openups-hid.h
=...