Peter Werner
2009-Jul-15 14:56 UTC
[Nut-upsuser] How to connect Trust UPS Energy Protector 400VA with nut
Hello list, I have been trying to figure out the whole day how I can connect our old Trust UPS Energy Protector 400VA with nut. But I have not made any progress yet and the worst is: I have no idea where to start although I read the documentation and search the web. My first problem is how to find out which driver I should take because this UPS is not in the compatibility list. The second issue is that it seems to be that every UPS has either a serial or a usb connection in order to communicate to the PC - but our old UPS has none. There are only power plug ins - and that is it. As far as I understand that UPS stuff - and I have not already told you that I am newbie with UPS ;-) it is some kind of contact closure device. It using the power connection to tell the PC if the power is low. So that means I should try the genericups driver if I understand right. But this driver also want a configured port - which one because I haven't any serial connection - and a upstype. But no one does fit. I also took a look into the description for the powercom and the megatec drivers - also in the source code. But I as I said - this does not bring me further. O.K: in the man page for the the genericups driver is described how you can test if the UPS can be control with nut. But - and this is my question - has never ever anybody used this UPS with nut? I not it is cheap UPS, it is old, etc. - but we have it and now we have a Linux which should use it. So if somebody has read that far and has maybe an advice for me is appreciated. Thanks for reading. -- Mit freundlichen Gr??en Kind Regards Peter Werner -------------------------------------- Steinhart Medizinsysteme GmbH Grubstra?e 6-8 D-79279 V?rstetten Tel.: +49(0)7666-90070 Fax.: +49(0)7666-900711 http://www.hipax.de Gesch?ftsf?hrer: Thomas Wittmer und Dr. Martina Steinhart Handelsregister B Freiburg i.Brsg. HRB 261362 VAT DE813672991 --------------------------------------
Arjen de Korte
2009-Jul-15 18:09 UTC
[Nut-upsuser] How to connect Trust UPS Energy Protector 400VA with nut
Citeren Peter Werner <p.werner op hipax.de>:> I have been trying to figure out the whole day how I can connect our old > Trust UPS Energy Protector 400VA with nut. But I have not made any > progress yet and the worst is: I have no idea where to start although I read > the documentation and search the web. > > My first problem is how to find out which driver I should take because > this UPS is not in the compatibility list. The second issue is that > it seems to > be that every UPS has either a serial or a usb connection in order > to communicate > to the PC - but our old UPS has none. There are only power plug ins - and > that is it.In that case, you can't monitor it. It isn't possible, because the maker of this device didn't provide an interface for monitoring. You'll only find this limitation on the rock bottom low priced devices and yours presumably is.> As far as I understand that UPS stuff - and I have not already told you > that I am newbie with UPS ;-) it is some kind of contact closure device.Even those devices will be equipped with a monitoring port and generally, this will be a DB-9 connector that connects to a RS-232 port (sometimes via a specially wired cable). But if there is not port, you're out of luck.> It using the power connection to tell the PC if the power is low.There are plans to do this (powerline communication) but as far as I know, there is no manufacturer of PC power supplies that supports this. It is a great idea, that would do away with a lot of headaches for signaling the power state, but so far this has never gone beyond great ideas. In any case, NUT can't help you with this.> So that > means I should try the genericups driver if I understand right.Not at all. Even that one needs a serial port (I'm quite sure that is written somewhere in the documentation as well, but you seem to have missed that). Best regards, Arjen -- Please keep list traffic on the list