2019 Jan 27
4
Just an interesting data point
SO, my full load on my core UPS is two Dell R610s, one Sun X4540, one HP DL360p gen8, two six-core Thuban-II workstations plua their monitors, and the network stack and KVM. The APC SU3000RM (3KVA) that blew up last week considered this to be just short of 60% load. The new Cyberpower PR3000 (also 3KVA), wqhich operates at a 90% power factor, considers this same load to be 43% load. I wasn't expecting that much of a reduction. I have the snmp-ups driver working with it, have not enable...
2016 Feb 13
2
nutdrv_qx - Device not supported
Hi I have the RCT 3KVA Axpert solar hybrid inverter. It is also known as the MPP Solar PIP-MS series, the IPS-4000WM and the Voltronic Axpert MKS. I am trying to monitor the inverter using NUT on a Raspberry Pi (I have tried Ubuntu as well with the same results). I have tried most of the drivers with no success. The...
2012 Apr 23
1
Advice on small office UPS
...stems like : Smart-UPS 2200VA LCD Smart-UPS XL 2200VA Smart-UPS 3000VA LCD. This includes adding the 2 extra servers I list above (Dell PE1800 and the HP). The Eaton UPS selector is very similar but seems to be suggesting quite different, larger, more expensive UPS systems like : Eaton 9170plus 3kVA HW Not only larger, but quite a bit more expensive. The Eaton 5PX 2200IRT seemed to be (roughly) equivalent to the Smart-UPS 2200VA, but without the experience or knowledge of this area, I don't know and the different results suggested by the tools would concern me. Any advice or thoughts o...
2019 Jan 28
0
Just an interesting data point [CyberPower SNMP]
...7, 2019, at 2:36 PM, Phil Stracchino <phils at caerllewys.net> wrote: > > SO, my full load on my core UPS is two Dell R610s, one Sun X4540, one HP > DL360p gen8, two six-core Thuban-II workstations plua their monitors, > and the network stack and KVM. > > The APC SU3000RM (3KVA) that blew up last week considered this to be > just short of 60% load. > The new Cyberpower PR3000 (also 3KVA), wqhich operates at a 90% power > factor, considers this same load to be 43% load. > > I wasn't expecting that much of a reduction. So... 50% load +/- 10% :-) (The u...
2016 Feb 15
1
nutdrv_qx - Device not supported
Hi Thank you very much for the feedback. I will download and try to get it working on the Raspberry Pi. Regards Tom On Sun, Feb 14, 2016 at 1:49 AM, hyouko at gmail.com <hyouko at gmail.com> wrote: > > I have the RCT 3KVA Axpert solar hybrid inverter. It is also known as > the > > MPP Solar PIP-MS series, the IPS-4000WM and the Voltronic Axpert MKS. I > am > > This device could be supported by nutdrv_qx (subdriver > 'voltronic-sunny') built starting from this branch: > https://githu...
2018 Sep 03
0
Adding drivers to NUT?
...Keor PDU is a commercial name for a Rack UPS, in the USB_DEVICE() macro I tried to add a small description, I don't know if it's enough for you, what kind of comment would you like? > > Regarding nutdrv_qx the only VID:PID combo is for one family: "Legrand Daker DK+ 1kVA / 2kVA / 3kVA / 5kVA / 6kVA / 10kVA". This could be the description. > The items were Static, so I changed the file accordingly, i also added the DEFAULT_ONDELAY and DEFAULT_OFFDELAY. Probably i forgot it in a first time! > These are the changes related to questions Nr. 1,2,3,4 of your previous email....
2023 Sep 23
1
Nut-upsdev Digest, Vol 206, Issue 5
...?? 0.016626??? No matching HID UPS found ?? 0.016658??? [D5] send_to_all: SETINFO driver.state "cleanup.exit" root at LOULOU:/tmp/nut# ./drivers/huawei-ups2000 -DDDDDD -d1 -s test -x port=auto -x vendorid=... -x productid=... -x subdriver=... Network UPS Tools - NUT Huawei UPS2000 (1kVA-3kVA) RS-232 Modbus driver 0.05 (2.8.0-2557-g81fca30b2) Warning: This is an experimental driver. Some features may not function correctly. ?? 0.000000??? [D3] main_arg: var='port' val='auto' ?? 0.000049??? [D6] testinfo_reloadable: var=port, infoname=driver.parameter.port, newval=au...
2023 Sep 23
1
Nut-upsdev Digest, Vol 206, Issue 5
...matching HID UPS found > 0.016658 [D5] send_to_all: SETINFO driver.state "cleanup.exit" > root at LOULOU:/tmp/nut# ./drivers/huawei-ups2000 -DDDDDD -d1 -s test -x > port=auto -x vendorid=... -x productid=... -x subdriver=... > Network UPS Tools - NUT Huawei UPS2000 (1kVA-3kVA) RS-232 Modbus driver > 0.05 (2.8.0-2557-g81fca30b2) > Warning: This is an experimental driver. > Some features may not function correctly. > > 0.000000 [D3] main_arg: var='port' val='auto' > 0.000049 [D6] testinfo_reloadable: var=port, > infoname=dr...
2014 May 27
1
Masterguard UPS A3000
...rcuit fails, then likely both will fail at the same time, since both come from the same powerline. 4) Taking cost into consideration, and current load requirements, I'm guessing that option A would provide a longer time on battery than any other solution? Considering that each of the current 3kVA UPS are each running at 1/6 load (ie, 16%, or 33% if both racks on the same 3kVA UPS) Which would you suggest as the best option? Other brands/models/etc? Any other advice? Thank you for your time and any advice. Regards, Adam -- Adam Goryachev Website Managers www.websitemanagers.com.au
2016 Feb 13
0
nutdrv_qx - Device not supported
> I have the RCT 3KVA Axpert solar hybrid inverter. It is also known as the > MPP Solar PIP-MS series, the IPS-4000WM and the Voltronic Axpert MKS. I am This device could be supported by nutdrv_qx (subdriver 'voltronic-sunny') built starting from this branch: https://github.com/zykh/nut/tree/nutdrv_qx_volt...
2011 Jan 21
0
APC Smart UPS 3000 LCD & Eaton Evolution S 3000
We're looking at supplementing our Belkin Regulator Pro 1400 with a 2nd UPS, and were contemplating the APC's 3kVA Smart UPS LCD. We'd still be using either our existing FreeBSD box or a CentOS box to control the UPS. I was just wondering if anyone's got much experience with using these with NUT. From the NUT compatibility guide, it says it uses the usb-hid driver. It also just dawned upon me to lo...
2005 Jun 20
1
Off Topic: UPS units and heat generation
Hi all A slightly off topic post, but one that I think someone out there in the NUT community could probably help me with. Summer is coming, and my office at home is getting hot... helped in part by the APC 3KVA UPS I have sitting under my desk. It kicks out heat like a bar-heater, even when there is almost no load on it (idle load is one PC, one switch, one wireless AP, and thats it). It is very warm to the touch, and just gets worse when I turn on the rest of the kit (tape autoloader, TFTs, CRTs, two...
2023 Sep 19
1
Nut-upsdev Digest, Vol 206, Issue 5
Well, now that the `subdriver` option got added to `usbhid-ups` too, you can at least try that (by building again the current master). See command-line help for the subdrivers it would currently recognize, and copy e.g. the first word as the matching option, e.g.: ./drivers/usbhid-ups -DDDDDD -d1 -s test -x port=auto -x vendorid=... -x productid=... -x subdriver=... and try to lockpick your
2019 Jan 28
2
Just an interesting data point [CyberPower SNMP]
On 1/27/19 9:13 PM, Charles Lepple wrote: > On Jan 27, 2019, at 2:36 PM, Phil Stracchino <phils at caerllewys.net > <mailto:phils at caerllewys.net>> wrote: >> The new Cyberpower PR3000 (also 3KVA), wqhich operates at a 90% power >> factor, considers this same load to be 43% load. >> >> I wasn't expecting that much of a reduction. > > So... 50% load +/- 10% :-) > > (The use of the term "calibration" for an UPS is slightly unfortunate - > it...
2011 Apr 28
1
Problem with blazer_ser/megatec when upgrading to 2.6.0 from 2.4
Hello First things first, thanks for great work with NUT. For years I used Informer compact 3kVA UPS http://www.informups.com/informer_compact.html with nut/megatec serial driver, but it stopped working when I switched to blazer_ser with 2.6.0 upgrade. I'm using 2.6.0 on gentoo. Blazer_ser seems to connect with UPS, but upsmon reports driver not connected. uname -a Linux localhost 2.6.36...
2018 Jul 26
5
Adding drivers to NUT?
Dear Daniele, nice to meet you, I'm a collegue of Gabriele. The problem with "blazer_usb" driver ("blazer_ser" works correctly) is related to the following commands: - "F" and "I": when the KRAULER subdriver check these UPS answers it uses wrong constants to check the lenght of the received packets, so these commands are considered as "not
2007 May 29
9
Asking hard questions about the NUT architecture
I've spent the better part of two working days reading the NUT code and documentation and thinking about typical modern use cases for the software. I'm now questioning whether I want to get any further involved with this project, because it seems to me that the codebase is a huge and complicated pile of machinery mainly aimed at solving problems that no longer matter. I could be wrong