Potential reboot problem with Polycom IP600 phones
...them to spontaneously
reboot at unpredictable times. It appears that if the amount of current
being delivered to the phone falls below a certain threshold, the phone
will reboot.
Here are the specific circumstances which will trigger this problem.
Standard AC power voltage in Japan ranges between 100V and 110V, as
opposed to the 110V to 120V in the USA. For the vast majority of
business equipment (including every Polycom product we have ever tested)
this is not an issue. However, it is an issue with the IP600. If the
transformer is receiving 100V AC -and- the speakerphone is in use -and-
the...
2005 May 31
1
asterisk acts as media gateway for existing pabx ?
Hi,
I'd like to realize the following setup traditional phones --> pbx
(non ip ) --> asterisk --- ISDN network
is it possible to set up an asterisk server in such way that it acts
as gateway between a traditionnal pbx and an isdn network ( I'm in
France ). this to let people continue with their existing pbx + phones
and enjoy voip features ?
outgoing calls:
if yes,do I need
2005 Sep 01
4
Overhead Paging Systems...
Hey all,
I know you all saw the topic and let out a groan. However, I understand
how to get an overhead paging system to work with respect *, however I am
now looking for a small(?) paging amp, that I could hook 3 or 4 horns to.
I would like to just have the * extention be routed to a soundcard and out
an output, so I would like an amp that is voice signal activated.
Has anyone found anything
2006 Dec 22
1
Powercom BNT-1200AP driver
...* byte 11 is UPS model Name
KIN = 4BH BNT = 42H
* byte 12 is UPS model number
* 100V = X0H 110V = X1H 115V = X2H 120V = X3H
* 200V = X7H 220V = X8H 230V = X9H 240V = XAH
* byte 13 is XX
*...
2006 Mar 27
3
[LLVMdev] PyPy Tokyo sprint 23/4 - 29/4 announcement
...f the various teams. Ending
on Saturday with
a Closure session - summing of the work and planning work to be done
until the next sprint.
Network, Food, currency
------------------------
We will have access to WiFi at AIST - please make sure you have wlan
capabilities.
Electricity outlets: 100V (adapters needed for european standard).
Currency is Japanese yen. There are Citibank cash machines that
accepts cash withdrawals from the major cards such as VISA and
Mastercard.
But it is a good idea to bring cash.
Also note that cell phones (european) are not very compatible with
the Japan...
2023 Feb 19
2
Using 'dummy.ups' for a real application, not just testing...
Good Morning,
I am working on setting up a 12V DC UPS that will power a NAS and a router
for a few hours. It contains some lithium-ion batteries, and a BMS to
control charging. Since it is just a dumb box with batteries, it has no
intelligence to inform the NAS of its status. This is where NUT comes in...
I would like to incorporate a Raspberry Pi NUT server into this scheme.
The Rpi can
2007 Jun 26
5
Inexpensive Layer 3 Switch?
Any recommendations on an economical layer 3 switch? Preferably something that you have hands on experience with connecting to IP phones with attached PCs? Specifically I need the ability to set the VLAN in the phone to tag voice packets and to set a native VLAN on a per port basis on the switch to put the untagged packets from the attached PC into a separate VLAN.
POE is not a requirement