Gene Heskett
2020-Oct-29 01:56 UTC
[Nut-upsuser] Can't get CyberPower UPS to work with Raspberry Pi 4
On Wednesday 28 October 2020 21:32:02 Charles Lepple wrote:> On Oct 26, 2020, at 9:38 AM, Gene Heskett <gheskett at shentel.net> wrote: > >>> battery.voltage: 24.0 > >>> battery.voltage.nominal: 24 > >> > >> I don't have the citation handy, but I think another user reported > >> that the battery.voltage returned by the UPS is a constant 24.0 V, > >> regardless of the actual battery voltage. > > [...] > > > I think it may be dependent on thhe ups. I have a 625 WA cyberpower > > on an rpi4, and I believe its more truthfull. Is this helpfull? > > You're right, the lack of a battery voltage sensor isn't true for all > CPS hardware. > > I was trying to make the point that the 24.0 V reading is suspect, > while covering the cases where broken scaling means that NUT displays > it as 16.0 V. > > However, back in January, we discussed the input.transfer.high/.low > issue: > https://alioth-lists.debian.net/pipermail/nut-upsuser/2020-January/011 >668.html > > The root cause of that is closer to some of the other CPS issues, like > the "output.voltage: 137.0" that Robert posted. > > That upsc dump is useful. For completeness, could you (and Robert) > please post the output of "upsrw myups"pi at rpi4:/media/pi/workspace $ upsrw myups [battery.charge.low] Remaining battery level when UPS switches to LB (percent) Type: STRING Maximum length: 10 Value: 10 [battery.runtime.low] Remaining battery runtime when UPS switches to LB (seconds) Type: STRING Maximum length: 10 Value: 300 [input.transfer.high] High voltage transfer point (V) Type: STRING Maximum length: 10 Value: 0 [input.transfer.low] Low voltage transfer point (V) Type: STRING Maximum length: 10 Value: 0 [ups.delay.shutdown] Interval to wait after shutdown with delay command (seconds) Type: STRING Maximum length: 10 Value: 120 [ups.delay.start] Interval to wait before (re)starting the load (seconds) Type: STRING Maximum length: 10 Value: 0> and "upscmd -l myups"?pi at rpi4:/media/pi/workspace $ upscmd -l myups Instant commands supported on UPS [myups]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use beeper.disable or beeper.mute) beeper.on - Obsolete (use beeper.enable) load.off - Turn off the load immediately load.off.delay - Turn off the load with a delay (seconds) load.on - Turn on the load immediately load.on.delay - Turn on the load with a delay (seconds) shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off shutdown.stop - Stop a shutdown in progress test.battery.start.deep - Start a deep battery test test.battery.start.quick - Start a quick battery test test.battery.stop - Stop the battery test Which looks very incomplete to me. OTOH, its not a very big UPS but neither is the pi. I have tested that, and it shuts off long before it outouts a LB signal. But as the old saw says, its not my job to blow the whistle. I'm just happy that it protects the pi while the Generac is being started. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D. Brandeis Genes Web page <http://geneslinuxbox.net:6309/gene>
Charles Lepple
2020-Oct-30 02:12 UTC
[Nut-upsuser] Can't get CyberPower UPS to work with Raspberry Pi 4
On Oct 28, 2020, at 9:56 PM, Gene Heskett <gheskett at shentel.net> wrote:> > Which looks very incomplete to me. OTOH, its not a very big UPS but > neither is the pi. I have tested that, and it shuts off long before it > outouts a LB signal.Which part looks incomplete, the variables or the commands? Even the larger UPSes tend to return a lot of read-only values, and only provide a few knobs for shutdown-related settings.
Gene Heskett
2020-Oct-30 04:22 UTC
[Nut-upsuser] Can't get CyberPower UPS to work with Raspberry Pi 4
On Thursday 29 October 2020 22:12:00 Charles Lepple wrote:> On Oct 28, 2020, at 9:56 PM, Gene Heskett <gheskett at shentel.net> wrote: > > Which looks very incomplete to me. OTOH, its not a very big UPS but > > neither is the pi. I have tested that, and it shuts off long before > > it outouts a LB signal. > > Which part looks incomplete, the variables or the commands?Commands Charles. Since the pi is a very low drain bit of kit, I expected to be able to lengthen the shutdown delay, to at least use 50% of the battery, which should be several hours but its stuck at 2 minutes. Unreal, but it is what it is.> Even the larger UPSes tend to return a lot of read-only values, and > only provide a few knobs for shutdown-related settings.So I note running those cmds on this 1500wa APC under this desk. Disappointing... Take care now. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D. Brandeis Genes Web page <http://geneslinuxbox.net:6309/gene>