Gene Heskett
2019-Sep-14 19:30 UTC
[Nut-upsuser] Changing UPS to a bigger APC 1500 1000WA, what driver?
I've drug it as far under the table as I can get it on a 30% heart. Yeah, I'm getting on, I'll be 85 in about 2 weeks. Heart surgury will be scheduled in the next few days to replace a worn out, leaky aortic valve. Piece if cake if my veins are big enough. So what driver do I use with a Smart-UPS_1500??? Never mind it was found and accessed by the bootup! upsc my usp reports: gene at coyote:~$ upsc myups Init SSL without certificate database <<- whats this mean? battery.charge: 88 battery.charge.low: 10 battery.charge.warning: 50 battery.runtime: -1 battery.runtime.low: 150 battery.type: PbAc battery.voltage: 27.2 battery.voltage.nominal: 24.0 device.mfr: American Power Conversion device.model: Smart-UPS_1500 device.serial: 3S1906X11389 device.type: ups driver.name: usbhid-ups driver.parameter.offdelay: 120 driver.parameter.ondelay: 150 driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchronous: no driver.version: 2.7.4 driver.version.data: APC HID 0.96 driver.version.internal: 0.41 ups.beeper.status: enabled ups.delay.shutdown: 120 ups.firmware: UPS 03.5 / ID=1015 ups.mfr: American Power Conversion ups.mfr.date: 2019/02/06 ups.model: Smart-UPS_1500 ups.productid: 0003 ups.serial: 3S1906X11389 ups.status: OL CHRG ups.timer.reboot: -1 ups.timer.shutdown: 65535 ups.vendorid: 051d gene at coyote:~$ Which is a little less verbose than the smaller belkin I took out because its 3rd battery set had failed, apparently at least 3 shorted cells. I can recall the first time I setup nut to watch a ups, a cast iron bitch. An old wet batttery NCR that was bigger than my 30" tower computer. Ate battery's for breakfast too. This automatic configuration is a breath of fresh air, thank you very much. Amazing... Now I need to get something and finsh shoving it under the desk, piece of 1x4 about 4 feet long. Must be all of 70 lbs... Or I'm getting puny in my advanced years. I no longer can claim I am as good as I ever was, not even once. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D. Brandeis Genes Web page <http://geneslinuxbox.net:6309/gene>
Charles Lepple
2019-Sep-15 17:44 UTC
[Nut-upsuser] Changing UPS to a bigger APC 1500 1000WA, what driver?
On Sep 14, 2019, at 3:30 PM, Gene Heskett wrote:> > I've drug it as far under the table as I can get it on a 30% heart. > Yeah, I'm getting on, I'll be 85 in about 2 weeks. Heart surgury will be > scheduled in the next few days to replace a worn out, leaky aortic > valve. Piece if cake if my veins are big enough. >Hope the procedure goes well!> gene at coyote:~$ upsc myups > Init SSL without certificate database <<- whats this mean?It's a nuisance message. While NUT can support SSL to protect the passwords that upsmon sends to upsd, it doesn't apply to upsc, which doesn't send passwords. Known issue for 2.7.4.> Which is a little less verbose than the smaller belkin I took out because > its 3rd battery set had failed, apparently at least 3 shorted cells.The full set of variables is hiding behind another APC-specific protocol. At least this time the protocol is documented. I have a Smart-UPS C1000 that does the same thing. I've been meaning to mess with it, but so many other projects... Also, hard to argue with "it works". - Charles
Gene Heskett
2019-Sep-16 00:05 UTC
[Nut-upsuser] Changing UPS to a bigger APC 1500 1000WA, what driver?
On Sunday 15 September 2019 13:44:45 Charles Lepple wrote:> On Sep 14, 2019, at 3:30 PM, Gene Heskett wrote: > > I've drug it as far under the table as I can get it on a 30% heart. > > Yeah, I'm getting on, I'll be 85 in about 2 weeks. Heart surgury > > will be scheduled in the next few days to replace a worn out, leaky > > aortic valve. Piece if cake if my veins are big enough. > > Hope the procedure goes well! > > > gene at coyote:~$ upsc myups > > Init SSL without certificate database <<- whats this mean? > > It's a nuisance message. While NUT can support SSL to protect the > passwords that upsmon sends to upsd, it doesn't apply to upsc, which > doesn't send passwords. Known issue for 2.7.4. > > > Which is a little less verbose than the smaller belkin I took out > > because its 3rd battery set had failed, apparently at least 3 > > shorted cells. > > The full set of variables is hiding behind another APC-specific > protocol. At least this time the protocol is documented. I have a > Smart-UPS C1000 that does the same thing. I've been meaning to mess > with it, but so many other projects...I hear that, loud and clear.> Also, hard to argue with "it > works". >Yes, any attempt to argue with it makes one look like a fool.> - CharlesTake care of yourself Charles, the years are sneaking up on us both I suspect. I'll be 85 in a couple weeks. But ATM, I'm trying to get ahead of an rpi-4b that does not seem to want to make video, waiting on parts from Hong Kong. When it does work, I'll be running an 11x54" Sheldon lathe I cnc'd a couple years ago with it. Stuff like this Keeps me out of the bars don'cha know. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D. Brandeis Genes Web page <http://geneslinuxbox.net:6309/gene>