[Nut-upsuser] Eaton PW9130 1500VA-T with netxml-ups driver
Hello, I have some questions about netxml-ups driver. My UPS: Eaton PW9130 1500VA-T with Network Management Card. OS: Fedora 24 NUT 2.7.4 (from fedoraproject repo) Driver: netxml-ups. Results of upsc: ambient.humidity.high: 90 ambient.humidity.low: 5 ambient.temperature.high: 40 ambient.temperature.low: 5 battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.runtime: 69012 battery.runtime.low: 180 battery.voltage: 52 device.contact: Computer Room Manager device.location: Computer Room device.mfr: Eaton device.model: PW9130 1500VA-T device.serial: PL062A6342 device.type: ups driver.name: netxml-ups driver.parameter.pollinterval: 2 driver.parameter.port: http://192.168.0.1:80 driver.parameter.synchronous: no driver.version: 2.7.4 driver.version.data: MGEXML/0.25 driver.version.internal: 0.40 input.bypass.frequency: 49 input.bypass.voltage: 226 input.frequency: 49 input.frequency.nominal: 50 input.transfer.boost.high: 195 input.transfer.boost.low: 195 input.transfer.high: 276 input.transfer.low: 120 input.transfer.trim.high: 253 input.transfer.trim.low: 253 input.voltage: 226 input.voltage.nominal: 230 outlet.1.battery.charge.low: 0 outlet.1.delay.shutdown: 120 outlet.1.delay.start: 0 outlet.1.desc: Group1 outlet.1.status: on outlet.1.switchable: yes outlet.1.timer.shutdown: -1 outlet.1.timer.start: -1 outlet.2.battery.charge.low: 0 outlet.2.delay.shutdown: 120 outlet.2.delay.start: 0 outlet.2.desc: Group2 outlet.2.status: on outlet.2.switchable: yes outlet.2.timer.shutdown: -1 outlet.2.timer.start: -1 outlet.desc: Master outlet.switchable: no output.current: 0 output.frequency: 49 output.frequency.nominal: 50 output.voltage: 229 output.voltage.nominal: 230 ups.beeper.status: disabled ups.date: 2017/06/13 ups.delay.shutdown: 120 ups.firmware: 1.30 ups.firmware.aux: Network Management Card/Mosaic 4M 16M 55/JI ups.load: 0 ups.mfr: Eaton ups.model: PW9130 1500VA-T ups.power: 0 ups.power.nominal: 1500 ups.realpower: 0 ups.realpower.nominal: 1350 ups.serial: PL062A6342 ups.status: OL CHRG ups.temperature: 24 ups.test.result: done and passed ups.time: 20:02:29 ups.timer.shutdown: -1 ups.timer.start: -1 A. When UPS is on battery, ups.status is OB DISCH. If battery.charge becomes equal battery.charge.low, ups.status changes to OB DISCH FSD. LB state not appear before FSD. Server shutdown. This is good. But if battery.runtime becomes equal battery.runtime.low, ups.status not changes and stay the same - OB DISCH. Is it bug? B. Does the netxml-ups driver support any UPS management or available UPS monitoring only? Result of upscmd ?l is empty. upsdrvctl shutdown - won?t shutdown ups __________________ Kind Regards, Viacheslav -- Makoto Isao ---------------------------------------------------------------------- -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170707/d5ffea60/attachment.html>