Eric Cobb
2013-Oct-15 19:40 UTC
[Nut-upsuser] UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
Hello, My name is Eric Cobb and I am a Product Specialist with Tripp Lite. We have tested your latest NUT distributions against our HID USB compatible UPS systems and would like to know what is needed and/or who is needed to contact in order to updated the listing of compatible Tripp Lite UPS systems in your HCL list? Best Regards, Eric K. Cobb Product Management Specialist [Tripp Lite] 1111 W. 35th Street | Chicago IL 60609 USA 773.869.1203 | Fax 773.869.1935 website<http://www.tripplite.com/EN/index.cfm> | email<mailto:eric_cobb at tripplite.com> | [Reach Me on Skype]<eric.cobb21> [Follow us on Twitter] <http://twitter.com/tripplite> [Find us on Facebook] <http://www.facebook.com/TrippLite> [See us on YouTube] <http://www.youtube.com/profile?user=tripplite> [Find us on Linkedin] <http://www.linkedin.com/company/tripp-lite> This message is for the addressee?s use only. It may contain confidential information. If you receive this message in error, please delete it and notify the sender. Tripp Lite disclaims all warranties and liabilities, and assumes no responsibility for viruses which may infect an email sent to you from Tripp Lite and which damage your electronic systems or information. It is your responsibility to maintain virus detection systems to prevent damage to your electronic systems and information. ________________________________ This message is for the addressee's use only. It may contain confidential information. If you receive this message in error, please delete it and notify the sender. Tripp Lite disclaims all warranties and liabilities, and assumes no responsibility for viruses which may infect an email sent to you from Tripp Lite and which damage your electronic systems or information. It is your responsibility to maintain virus detection systems to prevent damage to your electronic systems and information. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0001.html> -------------- next part -------------- A non-text attachment was scrubbed... Name: image001.png Type: image/png Size: 5920 bytes Desc: image001.png URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0001.png> -------------- next part -------------- A non-text attachment was scrubbed... Name: image002.gif Type: image/gif Size: 1856 bytes Desc: image002.gif URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0005.gif> -------------- next part -------------- A non-text attachment was scrubbed... Name: image003.gif Type: image/gif Size: 1205 bytes Desc: image003.gif URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0006.gif> -------------- next part -------------- A non-text attachment was scrubbed... Name: image004.gif Type: image/gif Size: 1199 bytes Desc: image004.gif URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0007.gif> -------------- next part -------------- A non-text attachment was scrubbed... Name: image005.gif Type: image/gif Size: 754 bytes Desc: image005.gif URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0008.gif> -------------- next part -------------- A non-text attachment was scrubbed... Name: image006.gif Type: image/gif Size: 731 bytes Desc: image006.gif URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131015/a648b296/attachment-0009.gif>
Charles Lepple
2013-Oct-16 01:32 UTC
[Nut-upsuser] UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
On Oct 15, 2013, at 3:40 PM, Eric Cobb wrote:> My name is Eric Cobb and I am a Product Specialist with Tripp Lite. We have tested your latest NUT distributions against our HID USB compatible UPS systems and would like to know what is needed and/or who is needed to contact in order to updated the listing of compatible Tripp Lite UPS systems in your HCL list?Hi Eric, From end users of NUT, we usually request the information mentioned under "Report new devices, omissions or errors" at http://www.networkupstools.org/stable-hcl.html#footnotes However, I don't want to be pedantic about getting the exact output of 'upsc' from the entire Tripp Lite product line - especially if several models share the same USB controller. Getting the 'upsc' output from a representative model should be sufficient. What would be helpful is to understand which models are similar, and whether there are any attributes we can use to differentiate between various generations of the hardware (for instance, at some point the SMART2200RMXL2U changed from the proprietary serial-over-HID to standard PDC HID). Also, we occasionally run across cosmetic errors in the output data: http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 While this shouldn't affect the shutdown sequence, we do try to correct the returned measurements if we can identify a good algorithm. If all of the voltages are in microvolts (including the config voltages), we can apply a multiplier across the board. But if only some of the exponents are wrong, it is harder to write a general rule that won't break when the HID descriptor in the firmware is fixed. If there is a firmware revision that we can compare against, that can help isolate the bug fixes. The last piece (not visible on the HCL, but included in the data files for hotplug/udev) is the list of USB vendor/product IDs. If a new Tripp Lite product ID were to be encountered by NUT, the driver would not automatically attach to it unless the "productid" option is specified. It is a simple way to tell users that we did not know whether that device would work when that version of NUT was released, but that they can give it a shot (potentially getting incorrectly scaled voltages). We are open to suggestions on how to improve that heuristic, especially if Tripp Lite has allocated separate ranges of product IDs for UPS and non-UPS hardware. Here's the code in question: https://github.com/networkupstools/nut/blob/master/drivers/tripplite-hid.c#L57 In that file, the product IDs are matched individually, and there is a tripplite_claim() function at the bottom of the file which tries to offer advice for other IDs. Regards, -- Charles Lepple clepple at gmail
Kris Jordan
2013-Oct-16 01:47 UTC
[Nut-upsuser] UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
Eric Cobb wrote, On 10/15/2013 12:40 PM:> > Hello, > > My name is Eric Cobb and I am a Product Specialist with Tripp Lite. We > have tested your latest NUT distributions against our HID USB > compatible UPS systems and would like to know what is needed and/or > who is needed to contact in order to updated the listing of compatible > Tripp Lite UPS systems in your HCL list? >Interesting... it's nice to know that Tripp-lite has some interest in NUT. I have a SMART1050SLT that has been giving me troubles if I try to use it with anything but the Windows driver. PowerAlert keeps losing touch the UPS. Also, I never liked that it needs Java. This UPS also doesn't seem to like NUT, it causes the usbhid-ups driver to crash among other issues. I haven't had much time to poke at it further. Been wondering if the UPS itself is just bugged. Regards.
Mike.
2013-Oct-16 13:54 UTC
[Nut-upsuser] UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
On 10/15/2013 at 9:32 PM Charles Lepple wrote: |On Oct 15, 2013, at 3:40 PM, Eric Cobb wrote: | |> My name is Eric Cobb and I am a Product Specialist with Tripp Lite. We |have tested your latest NUT distributions against our HID USB compatible |UPS systems and would like to know what is needed and/or who is needed to |contact in order to updated the listing of compatible Tripp Lite UPS |systems in your HCL list? | |Hi Eric, | |>From end users of NUT, we usually request the information mentioned under |"Report new devices, omissions or errors" at |http://www.networkupstools.org/stable-hcl.html#footnotes | |However, I don't want to be pedantic about getting the exact output of |'upsc' from the entire Tripp Lite product line - especially if several |models share the same USB controller. Getting the 'upsc' output from a |representative model should be sufficient. | |What would be helpful is to understand which models are similar, and |whether there are any attributes we can use to differentiate between |various generations of the hardware (for instance, at some point the |SMART2200RMXL2U changed from the proprietary serial-over-HID to standard |PDC HID). | [snip] ============ If I may make a request here for one more piece of information requested from vendors: Whether or not the UPS has shutdown delay that can be initiated by NUT, i.e., I want to be able to tell the UPS to shutdown in 60 seconds so that I can shutdown the computer running NUT before the UPS kills power. It would be great if the number of seconds in the shutdown delay could be configured within NUT.
Eric Cobb
2013-Oct-30 15:29 UTC
[Nut-upsuser] UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
Hello Mr. Leppe, See the attached excel file that covers the current Tripp Lite HID compatible UPS systems. There is also an attached Word document covering the UPSC / UPSCMD / UPSRW information from the specific UPS systems. Let me know if this is adequate to get our additional HID compatible products added to the NUT HCL listing. Tripp Lite Eric K. Cobb Product Management Specialist 1111 W. 35th Street | Chicago IL 60609 USA 773.869.1203 | Fax 773.869.1935 Email: Eric_cobb at tripplite.com Website: www.tripplite.com This message is for the addressee?s use only. It may contain confidential information. If you receive this message in error, please delete it and notify the sender. Tripp Lite disclaims all warranties and liabilities, and assumes no responsibility for viruses which may infect an email sent to you from Tripp Lite and which damage your electronic systems or information. It is your responsibility to maintain virus detection systems to prevent damage to your electronic systems and information. -----Original Message----- From: Charles Lepple [mailto:clepple at gmail.com] Sent: Tuesday, October 15, 2013 8:33 PM To: Eric Cobb Cc: nut-upsuser list Subject: Re: [Nut-upsuser] UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems On Oct 15, 2013, at 3:40 PM, Eric Cobb wrote:> My name is Eric Cobb and I am a Product Specialist with Tripp Lite. We have tested your latest NUT distributions against our HID USB compatible UPS systems and would like to know what is needed and/or who is needed to contact in order to updated the listing of compatible Tripp Lite UPS systems in your HCL list?Hi Eric,>From end users of NUT, we usually request the information mentioned under "Report new devices, omissions or errors" at http://www.networkupstools.org/stable-hcl.html#footnotesHowever, I don't want to be pedantic about getting the exact output of 'upsc' from the entire Tripp Lite product line - especially if several models share the same USB controller. Getting the 'upsc' output from a representative model should be sufficient. What would be helpful is to understand which models are similar, and whether there are any attributes we can use to differentiate between various generations of the hardware (for instance, at some point the SMART2200RMXL2U changed from the proprietary serial-over-HID to standard PDC HID). Also, we occasionally run across cosmetic errors in the output data: http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 While this shouldn't affect the shutdown sequence, we do try to correct the returned measurements if we can identify a good algorithm. If all of the voltages are in microvolts (including the config voltages), we can apply a multiplier across the board. But if only some of the exponents are wrong, it is harder to write a general rule that won't break when the HID descriptor in the firmware is fixed. If there is a firmware revision that we can compare against, that can help isolate the bug fixes. The last piece (not visible on the HCL, but included in the data files for hotplug/udev) is the list of USB vendor/product IDs. If a new Tripp Lite product ID were to be encountered by NUT, the driver would not automatically attach to it unless the "productid" option is specified. It is a simple way to tell users that we did not know whether that device would work when that version of NUT was released, but that they can give it a shot (potentially getting incorrectly scaled voltages). We are open to suggestions on how to improve that heuristic, especially if Tripp Lite has allocated separate ranges of product IDs for UPS and non-UPS hardware. Here's the code in question: https://github.com/networkupstools/nut/blob/master/drivers/tripplite-hid.c#L57 In that file, the product IDs are matched individually, and there is a tripplite_claim() function at the bottom of the file which tries to offer advice for other IDs. Regards, -- Charles Lepple clepple at gmail ________________________________ This message is for the addressee's use only. It may contain confidential information. If you receive this message in error, please delete it and notify the sender. Tripp Lite disclaims all warranties and liabilities, and assumes no responsibility for viruses which may infect an email sent to you from Tripp Lite and which damage your electronic systems or information. It is your responsibility to maintain virus detection systems to prevent damage to your electronic systems and information. -------------- next part -------------- A non-text attachment was scrubbed... Name: NUT HCL-Tripp Lite.xlsx Type: application/vnd.openxmlformats-officedocument.spreadsheetml.sheet Size: 62488 bytes Desc: NUT HCL-Tripp Lite.xlsx URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131030/8e414caa/attachment-0001.xlsx> -------------- next part -------------- A non-text attachment was scrubbed... Name: Network UPS Tool layout for Tripp Lite USB HID compatible UPS Systems.docx Type: application/vnd.openxmlformats-officedocument.wordprocessingml.document Size: 30214 bytes Desc: Network UPS Tool layout for Tripp Lite USB HID compatible UPS Systems.docx URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20131030/8e414caa/attachment-0001.docx>
Seemingly Similar Threads
- UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
- UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
- UPS Product additions to NUT HCL list for compatible Tripp Lite UPS systems
- Tripp Lite SMART2200RMXL2U and Fedora Core 6 (NUT 2.0.3)?
- [HCL] Tripp-Lite Omnismart500 supported by tripplite_usb