2007 Dec 11
2
nut-2.2.1-pre2
Shamelessly reusing the announcement Arnaud sent about three months ago
for nut-2.2.1:
"We're preparing to release 2.2.1-pre2, so if you have some fixes to
backport on Testing, consider announcing it and doing asap.
As always, compatibilities update and bugfixes only!"
Regards, Arjen
--
Eindhoven - The Netherlands
Key fingerprint - 66 4E 03 2C 9D B5 CB 9B 7A FE 7E C1
2012 Dec 25
1
Blazer_usb Permissions problem: Input/output error
Merry Christmas to you all and best wishes!
I ran into exactly the same problem as described.
OS: FreeBSD 9.0-Rel
UPS: Eaton E-Series NV 600H
NUT: from Ports, nut-2.6.5_1
driver: blazer_usb
I am sure the problem is not permission-related as it occurs even when
the driver runs as root.
My tested recipe for USB permissions is:
1. run usbconfig to find where the device is connected. In my case:
2008 Oct 06
4
UPS (Megatec) with strange voltage values
Hello Nut List!
I have 2 "Lacerda 10KVA" UPS that returns strange values for Q1 and F
commands:
Q1
(215.0 215.0 219.0 004 60.0 2.27 39.0 00000001
F
#220.0 045 240.0 60.0
At least what I know about Megatec, It seems to say that it has a 240.0 V
battery with currently 2.27V. Quite strange.
I contacted Lacerda to help me interpret this values and they said that 2.27
is just 1 element
2024 Nov 11
3
Interpreting data from 220V input APC UPS
John Ackermann N8UR via Nut-upsuser
<nut-upsuser at alioth-lists.debian.net> writes:
> I am monitoring via the SNMP driver an APC SmartUPS that has split
> phase (2L + neutral) 240V input and 120/120 volt outputs. The data
> for the voltages is not what I'm expecting, and I am wondering how I
> should interpret it.
Wow, that sounds kind of industrial. Model?
Is the input an L14-20P? Or equivalent non-twistlock?
> Here is an example from upsc:
>
> input.L1-L2.voltage: 121
> input.L2-L3.voltage: 120
> input.vol...
2011 Mar 26
1
Help with Aiptek PowerWalker VFI 1000 LCD and Konig CMP1200
Hello,
I have just installed nut_2.6.0 from Debian testing, do anyone know the
correct driver for this ups? The blazer_usb don't report
battery-charge, the bundled software report charge and runtime.
root at pluto<~>upsc powerwalker
battery.voltage: 40.86
battery.voltage.nominal: 36.0
beeper.status: enabled
device.mfr:
device.model: HV 1K
device.type: ups
driver.name: blazer_usb
2008 Mar 06
3
problem with output voltage on a mustek ups
Hi there
I have a Mustek PowerMust 1000 USB using serial port /dev/ttyS0.
I use nut 2.2.1 with the megatec driver on Debian Lenny (testing),
running on an AMD64 X2.
(I was using a Debian Etch as slave, but to keep it simple I turned it off)
My problem is that sometimes the UPS is running OK, but when the
message "UPS is trimming incoming voltage" appears on knutclient (i.e.
OL TRIM in
2017 Jun 09
2
Help with Elite 800VA usb UPS
Use the name from ups.conf in front of "@localhost".
?The re?sult is quite different ;)
root at artu:~# upsc Elit at artu
Init SSL without certificate database
Error: Driver not connected
> What if you try nutdrv_qx without specifying megatec? (It should
> autodetect.)
>
?Here is the result:
?
root at artu:~# upsdrvctl start
Network UPS Tools - UPS driver controller
2023 Jan 17
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
...ar: FAILED
max_bypass_volt: 264
max_bypass_volt, settable range: 231..276
min_bypass_volt: 110
min_bypass_volt, settable range: 110..209
max_bypass_freq: 64.0
max_bypass_freq, settable range: 61.0..64.0
min_bypass_freq: 56.0
min_bypass_freq, settable range: 56.0..59.0
No values for battery high/low voltages
Using 'guesstimation' (low: 208.000000, high: 300.000000)!
setvar(ups.delay.start, 60)
setvar: SUCCEED
setvar(ups.delay.shutdown, 12)
setvar: SUCCEED
battery.charge: 100
battery.packs: 1
battery.protection: yes
battery.runtime: 600
battery.voltage: 272.9
battery.voltage.high: 300.00
battery...
2023 Jan 17
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
...ar: FAILED
max_bypass_volt: 264
max_bypass_volt, settable range: 231..276
min_bypass_volt: 110
min_bypass_volt, settable range: 110..209
max_bypass_freq: 64.0
max_bypass_freq, settable range: 61.0..64.0
min_bypass_freq: 56.0
min_bypass_freq, settable range: 56.0..59.0
No values for battery high/low voltages
Using 'guesstimation' (low: 208.000000, high: 300.000000)!
setvar(ups.delay.start, 60)
setvar: SUCCEED
setvar(ups.delay.shutdown, 12)
setvar: SUCCEED
battery.charge: 100
battery.packs: 1
battery.protection: yes
battery.runtime: 600
battery.voltage: 272.9
battery.voltage.high: 300.00
battery...
2023 Jan 13
1
battery.voltage Powercom Macan MRT-3000
Hello!
I left this line uncommented in powercom-hid.c for battery voltage:
{ "battery.voltage", 0, 0, "UPS.Battery.Voltage", NULL, "%.2f", 0, NULL },
and got some data different from the input voltage values
The Powercom support staff gave the following response to my question:
Dear Alex,
First of all , thank you for purchasing PCM MRT-3000 ups.
Regarding of your
2008 Apr 16
1
new information to understand
Hi,
I've been using nut for a while on a UPS with the generic driver. It
has worked well. Thankyou.
I've just installed a new UPS 'INVERTER Atlantic Star T3' and their
documentation speaks of megatec.
So I tried it. And I get lots of wonderful information I'm not used to seeing.
# upsc my_sai at localhost
battery.charge: 100.0
battery.voltage: 2.31
battery.voltage.nominal:
2013 Sep 16
2
Zigor Ebro 650 compatibility - revisited (on Windows, at least)
...VER 1.1
0.625000 send_to_all: SETINFO ups.mfr "ZIGOR"
0.625000 send_to_all: SETINFO ups.model "EBRO 650"
0.625000 send_to_all: SETINFO ups.firmware "VER 1.1"
0.625000 Vendor information read in 1 tries
0.625000 No values provided for battery high/low voltages in ups.conf
0.625000 send_to_all: SETINFO battery.voltage.low "10.40"
0.625000 send_to_all: SETINFO battery.voltage.high "13.00"
0.625000 Using 'guestimation' (low: 10.400000, high: 13.000000)!
0.625000 Battery runtime will not be calculated (runtimecal not...
2014 Feb 19
3
Logic problem in NUT with upscode2 driver
Hi All,
I have what is probably a 12 year old (or older) Compaq R3000 UPS
plugged into a FreeBSD 8 system running NUT version 2.6.5
This UPS contains a total of 16 batteries in 2 banks of 8,
each battery is 6 volts and the bank produces 50 volts.
The UPS monitors battery voltage and the battery charger in
the UPS works like this. For about 2 days it will apply a
charge/float/topping
2008 Feb 24
2
usbhid-ups using wrong value for battery voltage for Pulsar Evolution 500?
I suspect that the battery is failing on my Pulsar Evolution 500 (it
is several years old now) but I can't seem to get a valid battery
voltage from the UPS.
The following tests were done using NUT 2.2.1, but I first noticed
this with the trunk, and reproduced it with the current
branches/Testing as well.
The only two values I have seen for battery.voltage are 120.0 and 119.0, e.g.:
$ upsc
2010 Feb 04
0
Powercom BNT-800AP
While fundamentally working, I'm having a few issues with the driver...
The default voltage quads (for every model) are way off... Showing
~95v when it should be ~117V. I've changed the 4th/final coefficient
to +5.0, but haven't tested extensively (with fluctuating voltages).
The input/output voltage appears to be swapped _most of the time_.
When doing a battery test, or when unplugged, the input stays steady,
and the _output_ voltage reports a drop to ~15V. OTOH, when the UPS
is shutdown, the ordering appears correct, as the input stays steady,
and the output shows...
2011 Mar 31
2
Cyberpower CP850PFCLCD 120% battery charge
Hello all,
I have a CyberPower Systems CP850PFCLCD that I'm hooking up to NUT 2.4.3
from apt running under Ubuntu 10.04. Using the usbhid-ups driver, things
*seem* to work at first glance, but there are some odd issues. The most
notable issue is that the battery.charge indicator reads 120 when at full
charge. I came across this post here:
2024 Nov 11
1
Interpreting data from 220V input APC UPS
Hi --
I am monitoring via the SNMP driver an APC SmartUPS that has split phase
(2L + neutral) 240V input and 120/120 volt outputs. The data for the
voltages is not what I'm expecting, and I am wondering how I should
interpret it. Here is an example from upsc:
input.L1-L2.voltage: 121
input.L2-L3.voltage: 120
input.voltage: 121.20
output.current: 5.90
output.L1-L2.voltage: 119
output.L1.current: 5.90
output.L2-L3.voltage: 119
output.L2.current: 1...
2006 Aug 18
0
(no subject)
Dear Mr Claesson,
prepare for quite a long letter from me. I hope you will have time to read it. I bestowed a whole morning on trying to identify the correct upstype. Here are the results:
root@marto:/home/marto# /usr/local/ups/bin/powercom -DD -u root -a Inform -x type=KP625AP
Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.4)
debug level is '2'
2011 Nov 08
0
mge-xml.c voltage conversion problem
...to fix it.
Now local representative sent me an MGE "Pulsar Extreme 2000 VA" model
in order to find an alternative way to poll our two
"Galaxy 5000 UPS" units.
I started the tests with netxml-ups driver. The very first thing
I noticed that upsc reports 1/10th of input/output AC voltages.
Raw HTTP stream:
[...]
<OBJECT name='UPS.PowerConverter.Output.Phase[1].ActivePower'>0</OBJECT>
<OBJECT name='UPS.PowerConverter.Output.Phase[1].ApparentPower'>0</OBJECT>
<OBJECT name='UPS.PowerConverter.Input[2].Phase[11].Voltage'>0</OBJEC...
2006 Feb 26
2
Voltage transfer points.
Hi,
Need to get an answer to the following. I find the naming to be
little redundant regarding the 'input.transfer.boost.low - hige'.
The same goes for input.transfer.trim.low - high.
As I find it, there is only one point where the boost or buck (trim)
kicks in.
Let's say that the nominal voltage is 230 volt, then we have a
input.transfer.boost point on say 220 volt.
If the