OS: Linux NUT version: 2.6.1 or 2.6.3 both have this issue UPS model: APC Smart-UPS 750 (051D/0002) Driver: usbhid-ups Question: I using upsc command to check ups status. When UPS is online, status is "OL". But when UPS is offline, status will not change to OB immediately. After test many times. this delay time didn't have any rules. Maybe immediately or few seconds or few minutes. It will cause doing ONBATT action also delayed. Does any method to solve this issue? or have some false range time for users? I using APC official software on Windows it will detect immediately. So I think this is not UPS machine issue. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20130220/4968d477/attachment.html>
Oleg Semyonov
2013-Feb-20 08:39 UTC
[Nut-upsuser] Detect ups.status on battery seems a little delay
> UPS model: APC Smart-UPS 750 (051D/0002) > But when UPS is offline, status will not change to OB immediately. > After test many times. this delay time didn't have any rules. Maybeimmediately or few seconds or few minutes.> It will cause doing ONBATT action also delayed.I asked exactly the same question on the 29th of January, and got nothing in reply. It doesn't seem to be a bike shedding problem, so nobody bothered, including developers (about using non-documented and probably non-supported option value). http://en.wikipedia.org/wiki/Parkinson's_law_of_triviality Short solution: set pollinterval=0 in driver configuration. It will report OB/OL immediately (but with a bit more CPU load). Full description: see my question here: http://lists.alioth.debian.org/pipermail/nut-upsuser/2013-January/008195.htm l Oleg
Oleg Semyonov
2013-Feb-20 08:41 UTC
[Nut-upsuser] Detect ups.status on battery seems a little delay
http://lists.alioth.debian.org/pipermail/nut-upsuser/2013-January/008195.htm l Sorry, last ?L? was missing in previous post. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20130220/7ba82a3e/attachment-0001.html>
Maybe Matching Threads
- battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
- Shutdown when both (all) UPS on battery / low battery
- Shutdown when both (all) UPS on battery / low battery
- battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
- battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error