Hi James, 2011/1/1 Among The Living <stinkysmellykid at gmail.com>> Hey there, > > After a few hours with tampering I got my UPS up and running. > > It's a "RocketFish 1025/1000va" (The model varies and is listed as > 1000va as well as 1025va). > > I got it working with the usbhid-ups driver, which I guess is a no > brainer :P. Just figured I'd let you know. > > This product (As I found out by using good ole google cache on gentoos > forums), is just a rebrand of CyberPower's UPS's. >thanks for your report. can you please post an upsc output, so that we can validate that everything is fine, and confirm your compatibility submission? cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://www.eaton.com/mgeops Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr/ -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20110103/50671901/attachment-0001.htm>
2011/1/4 Among The Living <stinkysmellykid at gmail.com>> battery.charge: 100 > battery.charge.low: 10 > battery.charge.warning: 20 > battery.mfr.date: CPS > battery.runtime: 3600 > battery.runtime.low: 300 > battery.type: PbAcid > battery.voltage: 20.2 > battery.voltage.nominal: 12 > driver.name: usbhid-ups > driver.parameter.pollfreq: 30 > driver.parameter.pollinterval: 2 > driver.parameter.port: auto > driver.version: 2.2.2 > driver.version.data: CyberPower HID 0.1 > driver.version.internal: 0.33 > input.transfer.high: 140 > input.transfer.low: 90 > input.voltage: 117.0 > input.voltage.nominal: 120 > output.voltage: 117.0 > ups.beeper.status: enabled > ups.delay.shutdown: 20 > ups.delay.start: 30 > ups.load: 10 > ups.mfr: CPS > ups.model: UPS RF1025 > ups.productid: 0501 > ups.realpower.nominal: 88 > ups.status: OL > ups.timer.shutdown: -60 > ups.timer.start: 0 > ups.vendorid: 0764 >fine, thanks. I've just commited your entry (r2799). I missed to ask: have you tested low battery condition too? ie http://new.networkupstools.org/docs/user-manual.chunked/ar01s06.html#Testing_shutdowns I just double checked, the vendorid is in fact cyberpower, one question? :)> If the vendorid is actually derived from the device and not computed, > you should let users know to cross reference the vendorid against an > online database (if you haven't already). Totally didn't occur to me > until I was talking with a friend today :) >well, 2.8 work around user interface (not only graphical!) to detect (when possible), configure, test and monitor your devices will greatly improve the situation. many pieces of this are already in place. so 2.8.0 should be there quite quickly. On Mon, Jan 3, 2011 at 3:43 PM, Arnaud Quette <arnaud.quette at free.fr> wrote:> > Hi James, > > > > 2011/1/1 Among The Living <stinkysmellykid at gmail.com> > >> > >> Hey there, > >> > >> After a few hours with tampering I got my UPS up and running. > >> > >> It's a "RocketFish 1025/1000va" (The model varies and is listed as > >> 1000va as well as 1025va). > >> > >> I got it working with the usbhid-ups driver, which I guess is a no > >> brainer :P. Just figured I'd let you know. > >> > >> This product (As I found out by using good ole google cache on gentoos > >> forums), is just a rebrand of CyberPower's UPS's. > > > > thanks for your report. > > can you please post an upsc output, so that we can validate that > everything >cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr/ -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20110104/80443f55/attachment.htm>
2011/1/4 Among The Living <stinkysmellykid at gmail.com>> yep i definitely tested it, works great :) >thanks for the confirmation. cheers, Arnaud On Tue, Jan 4, 2011 at 1:31 PM, Arnaud Quette <arnaud.quette at free.fr> wrote:> > > > 2011/1/4 Among The Living <stinkysmellykid at gmail.com> > >> > >> battery.charge: 100 > >> battery.charge.low: 10 > >> battery.charge.warning: 20 > >> battery.mfr.date: CPS > >> battery.runtime: 3600 > >> battery.runtime.low: 300 > >> battery.type: PbAcid > >> battery.voltage: 20.2 > >> battery.voltage.nominal: 12 > >> driver.name: usbhid-ups > >> driver.parameter.pollfreq: 30 > >> driver.parameter.pollinterval: 2 > >> driver.parameter.port: auto > >> driver.version: 2.2.2 > >> driver.version.data: CyberPower HID 0.1 > >> driver.version.internal: 0.33 > >> input.transfer.high: 140 > >> input.transfer.low: 90 > >> input.voltage: 117.0 > >> input.voltage.nominal: 120 > >> output.voltage: 117.0 > >> ups.beeper.status: enabled > >> ups.delay.shutdown: 20 > >> ups.delay.start: 30 > >> ups.load: 10 > >> ups.mfr: CPS > >> ups.model: UPS RF1025 > >> ups.productid: 0501 > >> ups.realpower.nominal: 88 > >> ups.status: OL > >> ups.timer.shutdown: -60 > >> ups.timer.start: 0 > >> ups.vendorid: 0764 > > > > > > fine, thanks. I've just commited your entry (r2799). > > I missed to ask: have you tested low battery condition too? > > ie > > > http://new.networkupstools.org/docs/user-manual.chunked/ar01s06.html#Testing_shutdowns > > > >> I just double checked, the vendorid is in fact cyberpower, one question? > >> :) > >> If the vendorid is actually derived from the device and not computed, > >> you should let users know to cross reference the vendorid against an > >> online database (if you haven't already). Totally didn't occur to me > >> until I was talking with a friend today :) > > > > > > well, 2.8 work around user interface (not only graphical!) to detect > (when > > possible), configure, test and monitor your devices will greatly improve > the > > situation. > > many pieces of this are already in place. so 2.8.0 should be there quite > > quickly. > > > >> On Mon, Jan 3, 2011 at 3:43 PM, Arnaud Quette <arnaud.quette at free.fr> > >> wrote: > >> > Hi James, > >> > > >> > 2011/1/1 Among The Living <stinkysmellykid at gmail.com> > >> >> > >> >> Hey there, > >> >> > >> >> After a few hours with tampering I got my UPS up and running. > >> >> > >> >> It's a "RocketFish 1025/1000va" (The model varies and is listed as > >> >> 1000va as well as 1025va). > >> >> > >> >> I got it working with the usbhid-ups driver, which I guess is a no > >> >> brainer :P. Just figured I'd let you know. > >> >> > >> >> This product (As I found out by using good ole google cache on > gentoos > >> >> forums), is just a rebrand of CyberPower's UPS's. > >> > > >> > thanks for your report. > >> > can you please post an upsc output, so that we can validate that > >> > everything > > > > cheers, > > Arnaud > > -- > > Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com > > Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ > > Debian Developer - http://www.debian.org > > Free Software Developer - http://arnaud.quette.free.fr/ > > > > > >-------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20110105/3549496e/attachment.htm>