2009-Aug-28 02:32 UTC
[Nut-upsuser] Nut-upsuser post from cdubois@logilys.com requires approval
> Here is more informations. I hope this can help. Tell me if you need other > information. > > Version : Network UPS Tools upsd 2.2.0- > Driver : usbhid-ups > Network UPS Tools: 0.28 USB communication driver 0.28 - core > 0.30 (2.2.0-)Many improvements have been made to usbhid-ups since 2.2.0. You may want to upgrade, or at least check the ChangeLog to see what you might be missing. Try "upsrw ups at localhost" to see if your version of usbhid-ups has any options that might affect the low-battery charge setting.> [trixbox.logilys.net /]# upsc ups at localhost > battery.charge: 9 > battery.charge.low: 10 > battery.charge.warning: 50 > battery.date: not set > battery.mfr.date: 2008/11/25 > battery.runtime: 90 > battery.runtime.low: 120 > battery.type: PbAc > battery.voltage: 12.4 > battery.voltage.nominal: 12.0 > driver.name: usbhid-ups > driver.parameter.pollinterval: 2 > driver.parameter.port: auto > driver.version: 2.2.0- > driver.version.data: APC/CyberPower HID 0.9 > driver.version.internal: 0.30 > input.transfer.high: 139 > input.transfer.low: 92 > input.voltage: 122.0 > input.voltage.nominal: 115 > ups.beeper.status: enabled > ups.delay.shutdown: -1 > ups.firmware: 843.K1 .D > ups.firmware.aux: K1 > ups.load: 38 > ups.mfr: APC > ups.mfr.date: 2008/11/25 > ups.model: Back-UPS ES 550 > ups.productid: 0002 > ups.serial: 3B1808X13737 > ups.status: OL CHRG LB > ups.vendorid: 051d > > Thank you > > Christian, > > > -----Message d'origine----- > De : Charles Lepple [mailto:clepple at gmail.com] > Envoy? : 26 ao?t 2009 20:13 > ? : Christian Dubois > Cc : NUT user list > Objet : Re: [Nut-upsuser] Linux and the APC Back-UPS ES > > > On Aug 26, 2009, at 7:01 PM, Peter Selinger wrote: > >> Dear Christian, >> >> thanks for writing. I am no longer active in driver development, so I >> am forwarding your question to the NUT user list. The people on the >> list are very helpful. >> >> Best wishes, -- Peter >> >> Christian Dubois wrote: >>> >>> Hi there, I found this document on the internet and it was very >>> useful >>> for me (http://www.mscs.dal.ca/~selinger/ups/backups.html), thank >>> you. >>> >>> I successfully install and configure my ups over a Centos. My ups go >>> down on low battery when the power fail for a long period. >>> >>> But there is just a bug : my ups run out of battery before the end of >>> the shutdown process (a full shutdown take less than 2 minutes). >>> >>> Is there a way to "start the shutdown process earlier", or to >>> change the >>> battery.charge.low or battery.runtime.low variables? >>> >>> I try to set a FinalDelay to 0, but it doesn't help. >>> >>> Do you have any idea to help me? >>> >>> Thank you. > > Christian, > > Can you please post some more details, such as the version of NUT > which you are using, and which driver?-- - Charles Lepple
Reasonably Related Threads
- Linux and the APC Back-UPS ES
- [syslinux-owner@zytor.com: Syslinux post from upendra.gandhi@gmail.com requires approval]
- Syslinux post from zmau1962@gmail.com requires approval
- Riello patch and examples (was: Nut-upsdev post from e.parisi@riello-ups.com requires approval)
- [Fwd: Re: [Nut-packaging] Nut-packaging post from richard@aardvark.com.au requires approval]