Rushabh Sanghavi (Rush)
2025-Jan-31 03:50 UTC
[Nut-upsdev] Error "Data for UPS [pcmusb] is stale - check driver"
Dear NUT Developers,
A very good morning to you and hope that you are in the best of health and
spirits.
For an upcoming UPS Project, our team has been testing Powercom?s Cleanline
T-1500 UPS model whose photo has been attached with this e-mail. Our team has
been testing this UPS with one of our 4G LTE WiFi router models on which Network
UPS Tools (NUT) Version 2.8.0-3 has been installed. BUT during the testing our
team observed multiple instances of error message "Data for UPS [pcmusb] is
stale - check driver" being randomly reported by our 4G LTE WiFi router.
Here is the SUMMARY of the issue below for clear understanding purposes.
* NUT Version 2.8.0-3 was installed on our 4G LTE WiFi router by our team.
* Also our 4G LTE WiFi router had Linux Kernel Version 5.15.127, OpenWRT
Distribution release ?23.05.0-rc3? and OpenWRT Distribution Revision
?r23389-5deed175a5? installed on it.
* Powercom?s Cleanline T-1500 UPS was connected with our 4G LTE WiFi router
via USB to USB Cable Connection (i.e. USB Port on router side and USB Port on
UPS side)
Now when NUT installed on our 4G LTE WiFi router model unit tried to poll and
fetch values of different UPS parameters from Powercom?s Cleanline T-1500 UPS
model
after both UPS and router had been running for sometime (i.e. for random period
of time):
* router started reporting the error message ?Data for UPS [pcmusb] is
stale - check driver?
* after that router could not get UPS?s status any more unless we restart
the NUT service
* and the router started reporting the error message ?Data for UPS
[pcmusb] is stale - check driver? after running for sometime again
Note: [pcmusb] represents the name or identifier assigned to the UPS instance
within the NUT (Network UPS Tools) configuration
* Our team tried to increase value of NUT?s timers such as ?pollinterval?,
?pollfreq?, ?maxage? but still the issue could not get solved or fixed
* Kindly NOTE that our team tested the above with both the NUT Drivers i.e.
blazer_usb and nutdrv_qx. But the same error message mentioned above was
observed.
* Also kindly NOTE that our team also tried to test with NUT Driver
?usbhid-ups? but it is seems that this particular Driver is not supported by
Powercom?s Cleanline T-1500 UPS model whose photo has been attached with this
e-mail.
* Currently our team is not 100% sure about the exact root cause.
Our team need to know the following from NUT Developers.
* Which the is correct NUT Driver that our team need to use on the 4G LTE
WiFi router so that it can communicate smoothly and successfully with Powercom?s
Cleanline T-1500 UPS model whose photo has been attached with this e-mail?
* Which specific parameters within the default Configuration Settings file
of NUT Version 2.8.0-3 on our 4G LTE WiFi router need to be tweaked / changed so
that our 4G LTE WiFi router model can communicate with the Powercom?s Cleanline
T-1500 UPS model smoothly and successfully?
* Which specific parameters within the default ups.conf / upsd.conf file on
our 4G LTE WiFi router needs to be tweaked / changed so that our 4G LTE WiFi
router model can communicate with the Powercom?s Cleanline T-1500 UPS model
smoothly and successfully?
Also I am hereby attaching the Log Files with the Log Messages reported on our
4G LTE WiFi router model. The 1st Log file contains Log Messages during testing
with NUT Driver ?blazer_usb? while the 2nd Log file contains Log Messages during
testing with NUT Driver ?nutdrv_qx?. You will observe the ERROR Message ?Data
for UPS [pcmusb] is stale - check driver? within both these attached Log Files.
Awaiting your swift response back.
Thanking you,
Yours sincerely,
[Legs Logo]
Rushabh N. S
Research and Development Director
PP Ontime Company Limited
PP Group of Companies
Address: 1011 Supalai Grand Tower,
16th Floor, Rama 3 Road,
Chongnonsi, Yannawa,
Bangkok ? 10120, Thailand
Landline No: +66-2-0562099 Ext. 2201
Fax No: +66-2-0562088
Cell Phone No: +66-8-59118578 / +66-6-22236221
E-mail: rushabh at pp-ontime.co.th<mailto:rushabh at pp-ontime.co.th>
Web: www.pp-ontime.co.th<http://www.pp-ontime.co.th>
Skype ID: rushabh.sanghavi
Disclaimer:
***************************************************************
Important
Confidentiality: This Information is intended for the above-named person and may
contain confidential and/or legally privileged material. Any opinions expressed
in this information are not necessarily those of the company. If it has come to
you in error you must take no action based on it, nor must you copy or show it
to anyone; please delete/destroy and inform the sender immediately.
Monitoring/Viruses/Malwares
PP-Ontime reserves the right to monitor all incoming and outgoing emails via
PP-Ontime's systems. Although we have security program to monitor and
eliminate virus/malware, we also advise that in keeping with good computing
practice the recipient should ensure they are actually virus/malwares free.
***************************************************************
Disclaimer:
***********************************************************************************************
Important
Confidentiality: This Information is intended for the above-named person and may
contain confidential and/or legally privileged material. Any opinions expressed
in this information are not necessarily those of the company. If it has come to
you in error you must take no action based on it, nor must you copy or show it
to anyone; please delete/destroy and inform the sender immediately.
Monitoring/Viruses/Malwares
PP-Ontime reserves the right to monitor all incoming and outgoing emails via
PP-Ontime's systems. Although we have security program to monitor and
eliminate virus/malware, we also advise that in keeping with good computing
practice the recipient should ensure they are actually virus/malwares free.
**********************************************************************************************
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
<http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20250131/6c7c01fa/attachment-0001.htm>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: image001.jpg
Type: image/jpeg
Size: 4031 bytes
Desc: image001.jpg
URL:
<http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20250131/6c7c01fa/attachment-0001.jpg>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: Powercom?s Cleanline T-1500 UPS model.png
Type: image/png
Size: 1720860 bytes
Desc: Powercom?s Cleanline T-1500 UPS model.png
URL:
<http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20250131/6c7c01fa/attachment-0001.png>
-------------- next part --------------
2023-08-19T21:01:23.000000+07:00 PPL404I-112 boot[1062] *********************
PWR logger-Power Up(syslog) *******************
2023-08-19T21:02:09.899836+07:00 PPL404I-112 : [origin
software="rsyslogd" swVersion="8.2110.0"
x-pid="3237" x-info="https://www.rsyslog.com"] start
2023-08-19T21:02:17.574925+07:00 PPL404I-112 netifd: Interface 'lan' is
enabled
2023-08-19T21:02:17.593870+07:00 PPL404I-112 netifd: Interface 'lan' is
now up
2023-08-19T21:02:17.750734+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T21:02:17.754789+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T21:02:18.319623+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T21:02:18.322773+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T21:02:18.335565+07:00 PPL404I-112 netifd: Interface
'loopback' is enabled
2023-08-19T21:02:18.349058+07:00 PPL404I-112 netifd: Interface
'loopback' is now up
2023-08-19T21:02:18.469042+07:00 PPL404I-112 netifd: Interface
'loopback' has link connectivity
2023-08-19T21:03:01.076794+07:00 PPL404I-112 mount_root: performing overlay
whiteout
2023-08-19T21:03:01.094361+07:00 PPL404I-112 mount_root: synchronizing overlay
2023-08-19T21:03:03.823783+07:00 PPL404I-112 mount_root: failed to sync jffs2
overlay
2023-08-19T21:03:04.026889+07:00 PPL404I-112 procd: /etc/rc.d/S96led: setting up
led lan4
2023-08-19T21:03:04.057303+07:00 PPL404I-112 procd: /etc/rc.d/S96led: setting up
led lan3
2023-08-19T21:03:04.087544+07:00 PPL404I-112 procd: /etc/rc.d/S96led: setting up
led lan2
2023-08-19T21:03:04.117803+07:00 PPL404I-112 procd: /etc/rc.d/S96led: setting up
led lan1
2023-08-19T21:03:04.147972+07:00 PPL404I-112 procd: /etc/rc.d/S96led: setting up
led wan
2023-08-19T21:03:06.866795+07:00 PPL404I-112 root: /opt/pp/CLI/sbin/pre_zl502.sh
2023-08-19T21:03:07.243849+07:00 PPL404I-112 urandom_seed[3920]: Seed saved
(/etc/urandom.seed)
2023-08-19T21:03:14.496260+07:00 PPL404I-112 root: service QoS Stop ...
2023-08-19T21:03:15.129140+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2023-08-19T21:03:16.777914+07:00 PPL404I-112 root: [usb_upsd]...Stopped
2023-08-19T21:03:22.542857+07:00 PPL404I-112 : [origin
software="rsyslogd" swVersion="8.2110.0"
x-pid="4716" x-info="https://www.rsyslog.com"] start
2023-08-19T21:03:22.698596+07:00 PPL404I-112 root:
/opt/pp/CLI/sbin/post_zl502.sh
2023-08-19T21:03:23.154963+07:00 PPL404I-112 root: service iptables Stop ...
2023-08-19T21:03:29.426692+07:00 PPL404I-112 root: service QoS Stop ...
2023-08-19T21:03:29.787026+07:00 PPL404I-112 dropbear[5350]: Child connection
from 192.168.99.55:60607
2023-08-19T21:03:30.284885+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2023-08-19T21:03:31.287002+07:00 PPL404I-112 procd: - init complete -
2023-08-19T21:03:33.712275+07:00 PPL404I-112 root: [usb_upsd]...Stopped
2023-08-19T21:03:36.263326+07:00 PPL404I-112 root: service iptables Stop ...
2023-08-19T21:03:37.649082+07:00 PPL404I-112 root: service iptables Starting ...
2023-08-19T21:03:46.873776+07:00 PPL404I-112 dropbear[5350]: Password auth
succeeded for 'admin' from 192.168.99.55:60607
2023-08-19T21:03:54.061711+07:00 PPL404I-112 CLI-admin[5350]: CLI
2023-08-19T21:03:54.696588+07:00 PPL404I-112 CLI-admin[5350]: CLI/status
2023-08-19T21:05:29.372934+07:00 PPL404I-112 CLI-admin[5350]: CLI/status/exit
2023-08-19T21:05:29.375523+07:00 PPL404I-112 CLI-admin[5350]: CLI
2023-08-19T21:05:29.850637+07:00 PPL404I-112 CLI-admin[5350]: CLI/config
2023-08-19T21:05:30.137665+07:00 PPL404I-112 CLI-admin[5350]:
CLI/config/cli_upload
2023-08-19T21:05:32.793551+07:00 PPL404I-112 CLI-admin[5350]:
CLI/config/write_config
2023-08-19T21:05:32.886342+07:00 PPL404I-112 root:
CLI-admin[5350]:CLI/config/write_config_CHANGE:cli.startup.disableservice=agentd
squid usb_upsd serial_upsd log xl2tpd dnsmasq keepalived odhcpd qos dot1x ->
agentd squid serial_upsd log xl2tpd dnsmasq keepalived odhcpd qos dot1x
2023-08-19T21:05:32.933318+07:00 PPL404I-112 root:
CLI-admin[5350]:CLI/config/write_config_CHANGE:cli.startup.enableservice=iptables
-> iptables usb_upsd
2023-08-19T21:05:32.970008+07:00 PPL404I-112 root:
CLI-admin[5350]:CLI/config/write_config_CHANGE:cli.startup.stop_as_reboot=iptables
-> squid
2023-08-19T21:05:33.424122+07:00 PPL404I-112 CLI-admin[5350]:
CLI/config/save_running_2flash
2023-08-19T21:05:34.293325+07:00 PPL404I-112 CLI-admin[5350]: CLI/config/exit
2023-08-19T21:05:34.295916+07:00 PPL404I-112 CLI-admin[5350]: CLI
2023-08-19T21:05:34.610059+07:00 PPL404I-112 CLI-admin[5350]: CLI/status
2023-08-19T21:05:35.653877+07:00 PPL404I-112 CLI-admin[5350]: CLI/status/reboot
2023-08-19T21:05:35.689666+07:00 PPL404I-112 procd: - shutdown -
2023-08-19T21:05:36.885986+07:00 PPL404I-112 reboot[7701]: *********************
logger-Reboot/Power Down *******************
2023-08-19T21:05:49.000000+07:00 PPL404I-112 boot[871] ********************* PWR
logger-Power Up(syslog) *******************
2023-08-19T21:06:19.867329+07:00 PPL404I-112 : [origin
software="rsyslogd" swVersion="8.2110.0"
x-pid="2502" x-info="https://www.rsyslog.com"] start
2023-08-19T21:06:24.262509+07:00 PPL404I-112 root: /opt/pp/CLI/sbin/pre_zl502.sh
2023-08-19T21:06:29.162773+07:00 PPL404I-112 root: service QoS Stop ...
2023-08-19T21:06:29.676175+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2023-08-19T21:06:30.730386+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN4 link down
2023-08-19T21:06:31.000326+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN3 link down
2023-08-19T21:06:31.231559+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T21:06:31.470125+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link up
2023-08-19T21:06:31.622387+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: wan link down
2023-08-19T21:06:33.190110+07:00 PPL404I-112 root:
/opt/pp/CLI/sbin/post_zl502.sh
2023-08-19T21:06:34.731948+07:00 PPL404I-112 root: service iptables Stop ...
2023-08-19T21:06:40.630388+07:00 PPL404I-112 root: service QoS Stop ...
2023-08-19T21:06:40.761775+07:00 PPL404I-112 procd: - init complete -
2023-08-19T21:06:42.384718+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2023-08-19T21:06:45.142091+07:00 PPL404I-112 root: [usb_upsd]...Stopped
2023-08-19T21:06:45.547068+07:00 PPL404I-112 root: service iptables Stop ...
2023-08-19T21:06:46.934705+07:00 PPL404I-112 root: service iptables Starting ...
2023-08-19T21:06:53.378196+07:00 PPL404I-112 netifd: Interface 'lan' is
enabled
2023-08-19T21:06:53.392948+07:00 PPL404I-112 netifd: Interface 'lan' is
now up
2023-08-19T21:06:53.796553+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T21:06:53.800564+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T21:06:54.072630+07:00 PPL404I-112 root: [nut-server-usb]...Stopped
2023-08-19T21:06:54.322793+07:00 PPL404I-112 root: [usb_upsd]...Started
2023-08-19T21:06:54.336915+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T21:06:54.340190+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T21:06:54.353951+07:00 PPL404I-112 netifd: Interface
'loopback' is enabled
2023-08-19T21:06:54.360262+07:00 PPL404I-112 netifd: Interface
'loopback' is now up
2023-08-19T21:06:54.585251+07:00 PPL404I-112 netifd: Interface
'loopback' has link connectivity
2023-08-19T21:07:04.408292+07:00 PPL404I-112 root: [nut-server-usb]...Stopped
2023-08-19T21:07:06.111381+07:00 PPL404I-112 upsd-usbd[5208]: listening on
127.0.0.1 port 6490
2023-08-19T21:07:06.290139+07:00 PPL404I-112 root: [nut-server-usb]...Started
2023-08-19T21:07:06.292024+07:00 PPL404I-112 upsd-usbd[5209]: Startup successful
2023-08-19T21:07:16.759065+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2023-08-19T21:07:19.840070+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:2/3
2023-08-19T21:07:20.858567+07:00 PPL404I-112 dropbear[5431]: Child connection
from 192.168.99.55:61559
2023-08-19T21:07:22.957189+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:3/3
2023-08-19T21:07:23.612976+07:00 PPL404I-112 dropbear[5431]: Password auth
succeeded for 'admin' from 192.168.99.55:61559
2023-08-19T21:07:26.044023+07:00 PPL404I-112 u_main.pl: Uupsd:COMMUNICATION
LOST-pls. check ups's connection
2023-08-19T21:07:26.675208+07:00 PPL404I-112 u_main.pl:
Uupsd:Start-Service:AC-Status=0:UPS-Status=:Manual-Shutdown=1:Beeper=enabled
2023-08-19T21:07:26.815726+07:00 PPL404I-112 u_main.pl:
Uupsd:UPS-Beeper=>Enable
2023-08-19T21:07:28.964514+07:00 PPL404I-112 hu_sys.pl:
Uupsd:Syslog_Interval=300
2023-08-19T21:07:35.156364+07:00 PPL404I-112 CLI-admin[5431]: CLI
2023-08-19T21:07:35.780644+07:00 PPL404I-112 CLI-admin[5431]: CLI/status
2023-08-19T21:07:37.519594+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/log0_trace -n 205
2023-08-19T21:08:00.150894+07:00 PPL404I-112 crond[2639]: USER root pid 6876 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2023-08-19T21:08:07.171723+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2023-08-19T21:08:08.322779+07:00 PPL404I-112 blazer_usb[7375]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2023-08-19T21:08:08.573995+07:00 PPL404I-112 blazer_usb[7375]: Supported UPS
detected with megatec protocol
2023-08-19T21:08:08.885592+07:00 PPL404I-112 blazer_usb[7375]: Vendor
information read in 1 tries
2023-08-19T21:08:09.141577+07:00 PPL404I-112 blazer_usb[7375]: Warning
information read in 1 tries
2023-08-19T21:08:09.621610+07:00 PPL404I-112 blazer_usb[7375]: Faultinfo
information read in 1 tries
2023-08-19T21:08:09.623371+07:00 PPL404I-112 blazer_usb[7375]: No values
provided for battery high/low voltages in ups.conf
2023-08-19T21:08:09.625487+07:00 PPL404I-112 blazer_usb[7375]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2023-08-19T21:08:09.627414+07:00 PPL404I-112 blazer_usb[7375]: Battery runtime
will not be calculated (runtimecal not set)
2023-08-19T21:08:09.797715+07:00 PPL404I-112 blazer_usb[7375]: Battery
information read in 1 tries
2023-08-19T21:08:11.248275+07:00 PPL404I-112 blazer_usb[7413]: Startup
successful
2023-08-19T21:08:13.135375+07:00 PPL404I-112 upsd-usbd[5209]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2023-08-19T21:08:13.135584+07:00 PPL404I-112 blazer_usb[7413]: sock_connect:
enabling asynchronous mode (auto)
2023-08-19T21:08:17.857033+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/ups_status
2023-08-19T21:08:21.404505+07:00 PPL404I-112 u_main.pl: Uupsd:COMMUNICATION
RESTORED
2023-08-19T21:08:25.167355+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/ups_status
2023-08-19T21:08:30.480533+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/log0_trace -n 205
2023-08-19T21:08:47.174131+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/log0_trace -n 205
2023-08-19T21:08:54.772881+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/ups_status
2023-08-19T21:08:59.624130+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/log0_trace
2023-08-19T21:09:07.050581+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/log0_trace -n 205
2023-08-19T21:09:28.092217+07:00 PPL404I-112 upsd-usbd[5209]: Data for UPS
[pcmusb] is stale - check driver
2023-08-19T21:09:29.270746+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2023-08-19T21:09:32.329146+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:2/3
2023-08-19T21:09:35.387564+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:3/3
2023-08-19T21:09:38.416010+07:00 PPL404I-112 u_main.pl: Uupsd:COMMUNICATION
LOST-pls. check ups's connection
2023-08-19T21:09:44.668992+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2023-08-19T21:09:45.784340+07:00 PPL404I-112 blazer_usb[9945]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2023-08-19T21:09:45.999004+07:00 PPL404I-112 blazer_usb[9945]: Supported UPS
detected with megatec protocol
2023-08-19T21:09:46.334578+07:00 PPL404I-112 blazer_usb[9945]: Vendor
information read in 1 tries
2023-08-19T21:09:46.670655+07:00 PPL404I-112 blazer_usb[9945]: Warning
information read in 1 tries
2023-08-19T21:09:46.998606+07:00 PPL404I-112 blazer_usb[9945]: Faultinfo
information read in 1 tries
2023-08-19T21:09:47.000057+07:00 PPL404I-112 blazer_usb[9945]: No values
provided for battery high/low voltages in ups.conf
2023-08-19T21:09:47.001677+07:00 PPL404I-112 blazer_usb[9945]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2023-08-19T21:09:47.002002+07:00 PPL404I-112 blazer_usb[9945]: Battery runtime
will not be calculated (runtimecal not set)
2023-08-19T21:09:47.190677+07:00 PPL404I-112 blazer_usb[9945]: Battery
information read in 1 tries
2023-08-19T21:09:48.715180+07:00 PPL404I-112 blazer_usb[10119]: Startup
successful
2023-08-19T21:09:48.791636+07:00 PPL404I-112 upsd-usbd[5209]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2023-08-19T21:09:50.302657+07:00 PPL404I-112 blazer_usb[10119]: sock_connect:
enabling asynchronous mode (auto)
2023-08-19T21:09:58.894199+07:00 PPL404I-112 u_main.pl: Uupsd:COMMUNICATION
RESTORED
2023-08-19T21:10:13.740512+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/ups_status
2023-08-19T21:10:16.862788+07:00 PPL404I-112 CLI-admin[5431]: CLI/status/version
2023-08-19T21:10:28.520441+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/log0_trace -n 205
2023-08-19T21:11:18.477807+07:00 PPL404I-112 CLI-admin[5431]:
CLI/status/ups_status
2023-08-19T21:13:08.658147+07:00 PPL404I-112 CLI-admin[5431]: CLI/status/ups_cmd
--help
2023-08-19T21:13:17.649528+07:00 PPL404I-112 CLI-admin[5431]: CLI/status/ups_cmd
127.0.0.1 1622 .1.3.6.1.2.1.33.1.2.28=1
2023-08-19T21:13:30.790936+07:00 PPL404I-112 dropbear[16058]: Child connection
from 192.168.99.55:58886
2023-08-19T21:13:40.232287+07:00 PPL404I-112 dropbear[16058]: Bad password
attempt for 'root' from 192.168.99.55:58886
2023-08-19T21:13:45.058482+07:00 PPL404I-112 dropbear[16058]: Bad password
attempt for 'root' from 192.168.99.55:58886
2023-08-19T21:13:48.820379+07:00 PPL404I-112 dropbear[16058]: Exit before auth
from <192.168.99.55:58886>: (user 'root', 2 fails): Disconnect
received
2023-08-19T21:14:21.828985+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T21:14:21.830058+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T21:14:22.504468+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link down
2023-08-19T21:14:22.835788+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T21:14:22.835899+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T21:14:27.092117+07:00 PPL404I-112 upsd-usbd[5209]: Data for UPS
[pcmusb] is stale - check driver
2023-08-19T21:14:27.110439+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2023-08-19T21:14:30.168607+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:2/3
2023-08-19T21:14:33.227400+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:3/3
2023-08-19T21:14:36.255561+07:00 PPL404I-112 u_main.pl: Uupsd:COMMUNICATION
LOST-pls. check ups's connection
2023-08-19T21:14:51.868486+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T21:14:51.869772+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T21:14:51.877481+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T21:14:51.877565+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T21:14:52.339490+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2023-08-19T21:18:20.986259+07:00 PPL404I-112 dropbear[5431]: Exit (admin) from
<192.168.99.55:61559>: Error reading: Connection reset by peer
2023-08-19T21:18:20.992782+07:00 PPL404I-112 CLI-admin[5431]: CLI/status/EOF
2023-08-19T21:19:43.611500+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T21:19:43.612550+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T21:19:44.647134+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T21:19:44.675924+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T21:19:44.676011+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T21:19:53.550042+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T21:19:53.551537+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T21:19:53.556294+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T21:19:53.556379+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T21:19:54.399860+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2023-08-19T21:19:57.021127+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T21:19:57.022169+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T21:19:57.872801+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T21:19:58.035771+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T21:19:58.035855+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T21:19:59.445743+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T21:19:59.447327+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T21:19:59.454405+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T21:19:59.454489+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T21:20:01.124803+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2023-08-19T21:25:27.955499+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2023-08-19T21:25:28.035851+07:00 PPL404I-112 upsd-usbd[5209]: Can't connect
to UPS [pcmusb] (blazer_usb-pcmusb): Connection refused
2023-08-19T21:25:29.084800+07:00 PPL404I-112 blazer_usb[29224]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2023-08-19T21:25:29.743913+07:00 PPL404I-112 blazer_usb[29224]: Supported UPS
detected with megatec protocol
2023-08-19T21:25:30.063575+07:00 PPL404I-112 blazer_usb[29224]: Vendor
information read in 1 tries
2023-08-19T21:25:30.279577+07:00 PPL404I-112 blazer_usb[29224]: Warning
information read in 1 tries
2023-08-19T21:25:30.599605+07:00 PPL404I-112 blazer_usb[29224]: Faultinfo
information read in 1 tries
2023-08-19T21:25:30.601026+07:00 PPL404I-112 blazer_usb[29224]: No values
provided for battery high/low voltages in ups.conf
2023-08-19T21:25:30.602632+07:00 PPL404I-112 blazer_usb[29224]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2023-08-19T21:25:30.604118+07:00 PPL404I-112 blazer_usb[29224]: Battery runtime
will not be calculated (runtimecal not set)
2023-08-19T21:25:30.935688+07:00 PPL404I-112 blazer_usb[29224]: Battery
information read in 1 tries
2023-08-19T21:25:32.402287+07:00 PPL404I-112 blazer_usb[29288]: Startup
successful
2023-08-19T21:25:34.042656+07:00 PPL404I-112 upsd-usbd[5209]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2023-08-19T21:25:34.044317+07:00 PPL404I-112 blazer_usb[29288]: sock_connect:
enabling asynchronous mode (auto)
2023-08-19T21:25:36.206533+07:00 PPL404I-112 dropbear[29325]: Child connection
from 192.168.99.55:49683
2023-08-19T21:25:38.403024+07:00 PPL404I-112 dropbear[29325]: Password auth
succeeded for 'admin' from 192.168.99.55:49683
2023-08-19T21:25:40.624404+07:00 PPL404I-112 CLI-admin[29325]: CLI
2023-08-19T21:25:42.160663+07:00 PPL404I-112 CLI-admin[29325]: CLI/config
2023-08-19T21:25:42.377245+07:00 PPL404I-112 u_main.pl: Uupsd:COMMUNICATION
RESTORED
2023-08-19T21:26:14.005663+07:00 PPL404I-112 CLI-admin[29325]: CLI/status
2023-08-19T21:26:15.163897+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/log0_trace -n 205
2023-08-19T21:26:21.436329+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/ups_status
2023-08-19T21:26:31.493993+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/ups_cmd 127.0.0.1 1621 .1.3.6.1.2.1.33.1.1.27=1
2023-08-19T21:26:32.142258+07:00 PPL404I-112 u_main.pl:
Uupsd:RECEIVED-Test-Battery-10s
2023-08-19T21:26:33.322691+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/log0_trace
2023-08-19T21:26:35.498872+07:00 PPL404I-112 u_main.pl:
Uupsd:Current-BatteryMinuteRemaining=>Alert:224.0
2023-08-19T21:26:35.584027+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Test_Inprogress:Start=2023-08-19
21-26-35:End=:AC-Status=0:UPS-Status=OL
CAL:Load=0:Battery-Charge=:Battery-Volt=40.50:Battery-Capacity=99.0:Battery-Remaining-Time=224.0
2023-08-19T21:26:46.111701+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Done:Start=2023-08-19 21-26-35:End=2023-08-19
21-26-46:AC-Status=0:UPS-Status=OL:Load=0:Battery-Charge=:Battery-Volt=41.04:Battery-Capacity=99.0:Battery-Remaining-Time=224.0
2023-08-19T21:27:19.057338+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/ups_cmd 127.0.0.1 1621 .1.3.6.1.2.1.33.1.1.28=1
2023-08-19T21:27:19.625464+07:00 PPL404I-112 u_main.pl:
Uupsd:RECEIVED-Test-Battery-1m
2023-08-19T21:27:22.160146+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/log0_trace -n 250
2023-08-19T21:27:22.195590+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-1m=>Test_Inprogress:Start=2023-08-19
21-27-22:End=:AC-Status=0:UPS-Status=OL
CAL:Load=0:Battery-Charge=:Battery-Volt=40.68:Battery-Capacity=99.0:Battery-Remaining-Time=224.0
2023-08-19T21:28:20.947795+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-1m=>Done:Start=2023-08-19 21-27-22:End=2023-08-19
21-28-20:AC-Status=0:UPS-Status=OL:Load=0:Battery-Charge=:Battery-Volt=42.30:Battery-Capacity=99.0:Battery-Remaining-Time=223.0
2023-08-19T21:31:40.749633+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/log0_trace -n 205
2023-08-19T21:33:14.519695+07:00 PPL404I-112 CLI-admin[29325]:
CLI/status/log0_trace -n 205
2023-08-19T21:34:23.222159+07:00 PPL404I-112 dropbear[19645]: Child connection
from 192.168.99.55:49754
2023-08-19T21:35:01.798571+07:00 PPL404I-112 dropbear[19645]: Password auth
succeeded for 'root' from 192.168.99.55:49754
2023-08-19T21:47:00.760961+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T21:47:00.762006+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T21:47:01.718585+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T21:47:01.795975+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T21:47:01.796061+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T21:52:40.026307+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T21:52:40.027597+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T21:52:40.036298+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T21:52:40.036382+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T21:52:40.472840+07:00 PPL404I-112 dropbear[19645]: Exit (root) from
<192.168.99.55:49754>: Error reading: Connection reset by peer
2023-08-19T21:52:40.474199+07:00 PPL404I-112 dropbear[29325]: Exit (admin) from
<192.168.99.55:49683>: Error reading: Connection reset by peer
2023-08-19T21:52:42.461429+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link up
2023-08-19T22:08:00.212969+07:00 PPL404I-112 crond[2639]: USER root pid 1385 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2023-08-19T22:54:12.479153+07:00 PPL404I-112 upsd-usbd[5209]: Data for UPS
[pcmusb] is stale - check driver
2023-08-19T22:54:12.497589+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2023-08-19T22:54:12.529251+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2023-08-19T22:54:12.610160+07:00 PPL404I-112 upsd-usbd[5209]: Can't connect
to UPS [pcmusb] (blazer_usb-pcmusb): Connection refused
2023-08-19T22:54:13.610227+07:00 PPL404I-112 blazer_usb[954]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2023-08-19T22:54:14.064004+07:00 PPL404I-112 blazer_usb[954]: Supported UPS
detected with megatec protocol
2023-08-19T22:54:14.543567+07:00 PPL404I-112 blazer_usb[954]: Vendor information
read in 1 tries
2023-08-19T22:54:14.759580+07:00 PPL404I-112 blazer_usb[954]: Warning
information read in 1 tries
2023-08-19T22:54:15.087608+07:00 PPL404I-112 blazer_usb[954]: Faultinfo
information read in 1 tries
2023-08-19T22:54:15.089050+07:00 PPL404I-112 blazer_usb[954]: No values provided
for battery high/low voltages in ups.conf
2023-08-19T22:54:15.091042+07:00 PPL404I-112 blazer_usb[954]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2023-08-19T22:54:15.092547+07:00 PPL404I-112 blazer_usb[954]: Battery runtime
will not be calculated (runtimecal not set)
2023-08-19T22:54:15.279684+07:00 PPL404I-112 blazer_usb[954]: Battery
information read in 1 tries
2023-08-19T22:54:16.922480+07:00 PPL404I-112 blazer_usb[1005]: Startup
successful
2023-08-19T22:54:18.615299+07:00 PPL404I-112 upsd-usbd[5209]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2023-08-19T22:54:18.616936+07:00 PPL404I-112 blazer_usb[1005]: sock_connect:
enabling asynchronous mode (auto)
2023-08-19T23:07:11.000000+07:00 PPL404I-112 boot[905] ********************* PWR
logger-Power Up(syslog) *******************
2023-08-19T23:07:42.623244+07:00 PPL404I-112 : [origin
software="rsyslogd" swVersion="8.2110.0"
x-pid="2546" x-info="https://www.rsyslog.com"] start
2023-08-19T23:07:46.879465+07:00 PPL404I-112 root: /opt/pp/CLI/sbin/pre_zl502.sh
2023-08-19T23:07:51.634506+07:00 PPL404I-112 root: service QoS Stop ...
2023-08-19T23:07:52.152207+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2023-08-19T23:07:53.389016+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN4 link down
2023-08-19T23:07:53.693070+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN3 link down
2023-08-19T23:07:53.882456+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T23:07:54.010956+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link down
2023-08-19T23:07:54.142391+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: wan link down
2023-08-19T23:07:55.667119+07:00 PPL404I-112 root:
/opt/pp/CLI/sbin/post_zl502.sh
2023-08-19T23:07:59.064655+07:00 PPL404I-112 root: service iptables Stop ...
2023-08-19T23:08:00.617947+07:00 PPL404I-112 crond[2683]: USER root pid 4080 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2023-08-19T23:08:02.300632+07:00 PPL404I-112 procd: - init complete -
2023-08-19T23:08:02.966390+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2023-08-19T23:08:03.303463+07:00 PPL404I-112 root: service QoS Stop ...
2023-08-19T23:08:07.753907+07:00 PPL404I-112 root: [usb_upsd]...Stopped
2023-08-19T23:08:09.312228+07:00 PPL404I-112 root: service iptables Stop ...
2023-08-19T23:08:10.880381+07:00 PPL404I-112 root: service iptables Starting ...
2023-08-19T23:08:16.282288+07:00 PPL404I-112 root: [nut-server-usb]...Stopped
2023-08-19T23:08:16.374744+07:00 PPL404I-112 netifd: Interface 'lan' is
enabled
2023-08-19T23:08:16.398426+07:00 PPL404I-112 netifd: Interface 'lan' is
now up
2023-08-19T23:08:16.421558+07:00 PPL404I-112 root: [usb_upsd]...Started
2023-08-19T23:08:17.536234+07:00 PPL404I-112 netifd: Interface
'loopback' is enabled
2023-08-19T23:08:17.545228+07:00 PPL404I-112 netifd: Interface
'loopback' is now up
2023-08-19T23:08:17.655464+07:00 PPL404I-112 netifd: Interface
'loopback' has link connectivity
2023-08-19T23:08:28.025357+07:00 PPL404I-112 root: [nut-server-usb]...Stopped
2023-08-19T23:08:29.407728+07:00 PPL404I-112 blazer_usb[5368]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2023-08-19T23:08:29.641919+07:00 PPL404I-112 blazer_usb[5368]: Supported UPS
detected with megatec protocol
2023-08-19T23:08:30.121427+07:00 PPL404I-112 blazer_usb[5368]: Vendor
information read in 1 tries
2023-08-19T23:08:30.377411+07:00 PPL404I-112 blazer_usb[5368]: Warning
information read in 1 tries
2023-08-19T23:08:30.697442+07:00 PPL404I-112 blazer_usb[5368]: Faultinfo
information read in 1 tries
2023-08-19T23:08:30.699200+07:00 PPL404I-112 blazer_usb[5368]: No values
provided for battery high/low voltages in ups.conf
2023-08-19T23:08:30.701180+07:00 PPL404I-112 blazer_usb[5368]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2023-08-19T23:08:30.703036+07:00 PPL404I-112 blazer_usb[5368]: Battery runtime
will not be calculated (runtimecal not set)
2023-08-19T23:08:30.873508+07:00 PPL404I-112 blazer_usb[5368]: Battery
information read in 1 tries
2023-08-19T23:08:32.481610+07:00 PPL404I-112 root: [nut-driver-usb]...Started
2023-08-19T23:08:32.483587+07:00 PPL404I-112 blazer_usb[5424]: Startup
successful
2023-08-19T23:08:32.573124+07:00 PPL404I-112 upsd-usbd[5426]: listening on
127.0.0.1 port 6490
2023-08-19T23:08:32.578247+07:00 PPL404I-112 upsd-usbd[5426]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2023-08-19T23:08:32.697938+07:00 PPL404I-112 upsd-usbd[5427]: Startup successful
2023-08-19T23:08:32.702933+07:00 PPL404I-112 root: [nut-server-usb]...Started
2023-08-19T23:08:33.953648+07:00 PPL404I-112 blazer_usb[5424]: sock_connect:
enabling asynchronous mode (auto)
2023-08-19T23:08:43.597805+07:00 PPL404I-112 u_main.pl: Uupsd:Current
load='0' vs Threshold='50'
2023-08-19T23:08:43.602882+07:00 PPL404I-112 u_main.pl: Uupsd:Current
Battery_MinuteRemaining='225.0' vs Threshold='252'
2023-08-19T23:08:43.605498+07:00 PPL404I-112 u_main.pl: Uupsd:Current
temperature='22.7' vs Threshold='50'
2023-08-19T23:08:43.743973+07:00 PPL404I-112 u_main.pl:
Uupsd:Start-Service:AC-Status=0:UPS-Status=OL:Manual-Shutdown=0:Beeper=enabled
2023-08-19T23:08:43.748783+07:00 PPL404I-112 u_main.pl:
Uupsd:UPS-Beeper=>Enable
2023-08-19T23:08:44.652927+07:00 PPL404I-112 hu_sys.pl:
Uupsd:Syslog_Interval=300
2023-08-19T23:14:55.340208+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T23:14:55.344164+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T23:14:55.355105+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T23:14:55.357089+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T23:14:55.808385+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link up
2023-08-19T23:15:06.627976+07:00 PPL404I-112 dropbear[14923]: Child connection
from 192.168.99.55:57585
2023-08-19T23:15:11.116001+07:00 PPL404I-112 dropbear[14923]: Password auth
succeeded for 'admin' from 192.168.99.55:57585
2023-08-19T23:15:19.481369+07:00 PPL404I-112 CLI-admin[14923]: CLI
2023-08-19T23:15:20.651202+07:00 PPL404I-112 CLI-admin[14923]: CLI/status
2023-08-19T23:15:20.670610+07:00 PPL404I-112 CLI-admin[14923]:
CLI/status/running_config | grep cli
2023-08-19T23:15:32.295414+07:00 PPL404I-112 CLI-admin[14923]:
CLI/status/running_config | grep ups
2023-08-19T23:16:29.923717+07:00 PPL404I-112 CLI-admin[14923]:
CLI/status/log0_trace
2023-08-19T23:16:34.622871+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T23:16:34.624423+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T23:16:35.025542+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link down
2023-08-19T23:16:35.647960+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T23:16:35.648044+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T23:18:18.735563+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T23:18:18.742477+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T23:18:18.767934+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T23:18:18.768022+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T23:18:19.678730+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2023-08-19T23:18:19.970822+07:00 PPL404I-112 dropbear[14923]: Exit (admin) from
<192.168.99.55:57585>: Error reading: Connection reset by peer
2023-08-19T23:18:21.149335+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T23:18:21.150391+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T23:18:22.207882+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T23:18:22.207969+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T23:18:22.939361+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T23:18:24.503606+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T23:18:24.504906+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T23:18:24.511181+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T23:18:24.511266+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T23:18:26.193644+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2023-08-19T23:19:01.519543+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2023-08-19T23:19:01.520593+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2023-08-19T23:19:01.930690+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2023-08-19T23:19:02.527841+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2023-08-19T23:19:02.527927+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2023-08-19T23:19:04.878474+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2023-08-19T23:19:04.879799+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2023-08-19T23:19:04.888037+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2023-08-19T23:19:04.888125+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2023-08-19T23:19:05.183832+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2023-08-19T23:20:19.446171+07:00 PPL404I-112 dropbear[22216]: Child connection
from 192.168.99.55:61794
2023-08-19T23:20:23.090034+07:00 PPL404I-112 dropbear[22216]: Password auth
succeeded for 'admin' from 192.168.99.55:61794
2023-08-19T23:20:25.688061+07:00 PPL404I-112 CLI-admin[22216]: CLI
2023-08-19T23:20:25.761441+07:00 PPL404I-112 CLI-admin[22216]: CLI/status
2023-08-19T23:20:27.883587+07:00 PPL404I-112 CLI-admin[22216]:
CLI/status/log0_trace -n 250
2023-08-19T23:24:36.554324+07:00 PPL404I-112 CLI-admin[22216]:
CLI/status/ups_status
2023-08-19T23:24:45.680728+07:00 PPL404I-112 CLI-admin[22216]:
CLI/status/log0_trace -n 2250 | grep driver
2023-08-19T23:24:53.580060+07:00 PPL404I-112 CLI-admin[22216]:
CLI/status/log0_trace -n 2250 | grep check
2023-08-19T23:25:15.780002+07:00 PPL404I-112 CLI-admin[22216]:
CLI/status/log0_trace -n 2500000 | grep stale
2023-08-19T23:25:22.076945+07:00 PPL404I-112 CLI-admin[22216]:
CLI/status/log0_trace
2023-08-19T23:29:25.079895+07:00 PPL404I-112 CLI-admin[22216]: CLI/status/date
-s '2025-01-24 14:10:00'
2025-01-24T14:10:23.062418+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T14:10:23.063468+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T14:10:24.091906+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T14:10:24.091991+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T14:10:25.652703+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T14:10:26.692384+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T14:10:26.693681+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T14:10:26.700455+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T14:10:26.700541+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T14:10:28.906529+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T14:10:31.909100+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T14:10:31.910151+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T14:10:32.159461+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T14:10:32.971967+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T14:10:32.972053+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T14:10:35.260568+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T14:10:35.263684+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T14:10:35.294359+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T14:10:35.294443+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T14:10:35.425932+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T14:10:35.551752+07:00 PPL404I-112 crond[2683]: time disparity of
754001 minutes detected
2025-01-24T14:10:38.778666+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T14:10:38.779750+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T14:10:39.771941+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T14:10:39.772025+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T14:10:41.942538+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T14:10:42.105134+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T14:10:42.106450+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T14:10:42.114072+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T14:10:42.114158+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T14:10:45.195700+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T14:11:19.208603+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T14:11:19.209654+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T14:11:20.251901+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T14:11:20.251987+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T14:11:21.925625+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T14:11:22.559250+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T14:11:22.560556+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T14:11:22.567790+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T14:11:22.567874+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T14:11:25.185026+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T14:12:37.302994+07:00 PPL404I-112 dropbear[5851]: Child connection
from 192.168.99.55:57536
2025-01-24T14:12:39.816396+07:00 PPL404I-112 dropbear[5851]: Password auth
succeeded for 'admin' from 192.168.99.55:57536
2025-01-24T14:12:42.219700+07:00 PPL404I-112 CLI-admin[5851]: CLI
2025-01-24T14:12:50.599791+07:00 PPL404I-112 CLI-admin[5851]: CLI/status
2025-01-24T14:12:52.104420+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/log0_trace -n 205
2025-01-24T14:12:59.769230+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/ups_status
2025-01-24T14:13:03.989687+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/log0_trace
2025-01-24T14:15:00.415744+07:00 PPL404I-112 CLI-admin[5851]: CLI/status/ups_cmd
127.0.0.1 1621 .1.3.6.1.2.1.33.1.1.27=1
2025-01-24T14:15:00.582456+07:00 PPL404I-112 dropbear[22216]: Exit (admin) from
<192.168.99.55:61794>: Error reading: Connection reset by peer
2025-01-24T14:15:00.588976+07:00 PPL404I-112 CLI-admin[22216]: CLI/status/EOF
2025-01-24T14:15:01.054356+07:00 PPL404I-112 u_main.pl:
Uupsd:RECEIVED-Test-Battery-10s
2025-01-24T14:15:01.456796+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/log0_trace
2025-01-24T14:15:02.492998+07:00 PPL404I-112 u_main.pl:
Uupsd:Current-BatteryMinuteRemaining=>Alert:225.0
2025-01-24T14:15:02.606445+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Test_Inprogress:Start=2025-01-24
14-15-02:End=:AC-Status=0:UPS-Status=OL
CAL:Load=0:Battery-Charge=100:Battery-Volt=40.68:Battery-Capacity=100.0:Battery-Remaining-Time=225.0
2025-01-24T14:15:11.194960+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T14:15:11.196017+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T14:15:12.252120+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T14:15:12.252205+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T14:15:12.554544+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T14:15:13.114149+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T14:15:13.115470+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T14:15:13.262660+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T14:15:13.262746+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T14:15:14.249757+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Done:Start=2025-01-24 14-15-02:End=2025-01-24
14-15-14:AC-Status=0:UPS-Status=OL:Load=0:Battery-Charge=100:Battery-Volt=41.04:Battery-Capacity=99.0:Battery-Remaining-Time=225.0
2025-01-24T14:15:16.556512+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T14:19:01.424100+07:00 PPL404I-112 CLI-admin[5851]: CLI/status/ups_cmd
127.0.0.1 1622 .1.3.6.1.2.1.33.1.2.31=1
2025-01-24T14:20:17.924522+07:00 PPL404I-112 CLI-admin[5851]: CLI/status/ups_cmd
127.0.0.1 1621 .1.3.6.1.2.1.33.1.1.27=1
2025-01-24T14:20:18.448100+07:00 PPL404I-112 u_main.pl:
Uupsd:RECEIVED-Test-Battery-10s
2025-01-24T14:20:19.158021+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/log0_trace
2025-01-24T14:20:21.806342+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Test_Inprogress:Start=2025-01-24
14-20-21:End=:AC-Status=0:UPS-Status=OL
CAL:Load=0:Battery-Charge=100:Battery-Volt=40.68:Battery-Capacity=99.0:Battery-Remaining-Time=225.0
2025-01-24T14:20:29.114539+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T14:20:29.115568+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T14:20:30.172037+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T14:20:30.172123+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T14:20:30.802475+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T14:20:31.094286+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T14:20:31.095545+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T14:20:31.103154+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T14:20:31.103239+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T14:20:31.530546+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Done:Start=2025-01-24 14-20-21:End=2025-01-24
14-20-31:AC-Status=0:UPS-Status=OL:Load=0:Battery-Charge=100:Battery-Volt=42.84:Battery-Capacity=99.0:Battery-Remaining-Time=225.0
2025-01-24T14:20:34.177267+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T14:21:02.462675+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/log0_trace
2025-01-24T14:22:34.876187+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/ups_status
2025-01-24T14:24:15.653258+07:00 PPL404I-112 CLI-admin[5851]: CLI/status/ups_cmd
127.0.0.1 1621 .1.3.6.1.2.1.33.1.1.27=1
2025-01-24T14:24:16.069826+07:00 PPL404I-112 u_main.pl:
Uupsd:RECEIVED-Test-Battery-10s
2025-01-24T14:24:17.027191+07:00 PPL404I-112 CLI-admin[5851]:
CLI/status/log0_trace
2025-01-24T14:24:19.424980+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Test_Inprogress:Start=2025-01-24
14-24-19:End=:AC-Status=0:UPS-Status=OL
CAL:Load=0:Battery-Charge=100:Battery-Volt=40.68:Battery-Capacity=99.0:Battery-Remaining-Time=225.0
2025-01-24T14:24:29.125694+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Done:Start=2025-01-24 14-24-19:End=2025-01-24
14-24-29:AC-Status=0:UPS-Status=OL:Load=0:Battery-Charge=100:Battery-Volt=42.66:Battery-Capacity=99.0:Battery-Remaining-Time=225.0
2025-01-24T14:27:19.468254+07:00 PPL404I-112 dropbear[7365]: Child connection
from 192.168.99.55:61016
2025-01-24T14:27:20.081939+07:00 PPL404I-112 dropbear[5851]: Exit (admin) from
<192.168.99.55:57536>: Error reading: Connection reset by peer
2025-01-24T14:27:22.358904+07:00 PPL404I-112 dropbear[7365]: Password auth
succeeded for 'admin' from 192.168.99.55:61016
2025-01-24T14:27:24.339007+07:00 PPL404I-112 CLI-admin[7365]: CLI
2025-01-24T14:27:27.799421+07:00 PPL404I-112 CLI-admin[7365]: CLI/status
2025-01-24T14:27:29.204222+07:00 PPL404I-112 CLI-admin[7365]:
CLI/status/log0_trace -n 205
2025-01-24T14:30:15.000632+07:00 PPL404I-112 upsd-usbd[5427]: Data for UPS
[pcmusb] is stale - check driver
2025-01-24T14:30:18.184424+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-24T14:30:18.222641+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-24T14:30:18.304472+07:00 PPL404I-112 upsd-usbd[5427]: Can't connect
to UPS [pcmusb] (blazer_usb-pcmusb): Connection refused
2025-01-24T14:30:19.306076+07:00 PPL404I-112 blazer_usb[11258]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2025-01-24T14:30:19.925885+07:00 PPL404I-112 blazer_usb[11258]: Supported UPS
detected with megatec protocol
2025-01-24T14:30:20.269552+07:00 PPL404I-112 blazer_usb[11258]: Vendor
information read in 1 tries
2025-01-24T14:30:20.461473+07:00 PPL404I-112 blazer_usb[11258]: Warning
information read in 1 tries
2025-01-24T14:30:20.805648+07:00 PPL404I-112 blazer_usb[11258]: Faultinfo
information read in 1 tries
2025-01-24T14:30:20.805748+07:00 PPL404I-112 blazer_usb[11258]: No values
provided for battery high/low voltages in ups.conf
2025-01-24T14:30:20.805905+07:00 PPL404I-112 blazer_usb[11258]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2025-01-24T14:30:20.805979+07:00 PPL404I-112 blazer_usb[11258]: Battery runtime
will not be calculated (runtimecal not set)
2025-01-24T14:30:21.117576+07:00 PPL404I-112 blazer_usb[11258]: Battery
information read in 1 tries
2025-01-24T14:30:22.600186+07:00 PPL404I-112 blazer_usb[11296]: Startup
successful
2025-01-24T14:30:24.311289+07:00 PPL404I-112 upsd-usbd[5427]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2025-01-24T14:30:24.311516+07:00 PPL404I-112 blazer_usb[11296]: sock_connect:
enabling asynchronous mode (auto)
2025-01-24T15:01:07.296067+07:00 PPL404I-112 upsd-usbd[5427]: Data for UPS
[pcmusb] is stale - check driver
2025-01-24T15:01:08.475687+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-24T15:01:08.505000+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-24T15:01:08.586705+07:00 PPL404I-112 upsd-usbd[5427]: Can't connect
to UPS [pcmusb] (blazer_usb-pcmusb): Connection refused
2025-01-24T15:01:09.640941+07:00 PPL404I-112 blazer_usb[21454]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2025-01-24T15:01:09.894050+07:00 PPL404I-112 blazer_usb[21454]: Supported UPS
detected with megatec protocol
2025-01-24T15:01:10.221681+07:00 PPL404I-112 blazer_usb[21454]: Vendor
information read in 1 tries
2025-01-24T15:01:10.613702+07:00 PPL404I-112 blazer_usb[21454]: Warning
information read in 1 tries
2025-01-24T15:01:10.957860+07:00 PPL404I-112 blazer_usb[21454]: Faultinfo
information read in 1 tries
2025-01-24T15:01:10.957959+07:00 PPL404I-112 blazer_usb[21454]: No values
provided for battery high/low voltages in ups.conf
2025-01-24T15:01:10.958123+07:00 PPL404I-112 blazer_usb[21454]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2025-01-24T15:01:10.958198+07:00 PPL404I-112 blazer_usb[21454]: Battery runtime
will not be calculated (runtimecal not set)
2025-01-24T15:01:11.133679+07:00 PPL404I-112 blazer_usb[21454]: Battery
information read in 1 tries
2025-01-24T15:01:12.616298+07:00 PPL404I-112 blazer_usb[21961]: Startup
successful
2025-01-24T15:01:14.593588+07:00 PPL404I-112 upsd-usbd[5427]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2025-01-24T15:01:14.595218+07:00 PPL404I-112 blazer_usb[21961]: sock_connect:
enabling asynchronous mode (auto)
2025-01-24T15:04:30.467286+07:00 PPL404I-112 CLI-admin[7365]:
CLI/status/log0_trace
2025-01-24T15:04:53.830371+07:00 PPL404I-112 CLI-admin[7365]:
CLI/status/log0_trace -n 25000000 | grep stale | grep check
2025-01-24T15:04:59.904764+07:00 PPL404I-112 CLI-admin[7365]:
CLI/status/log0_trace -n 25000000 | grep stale
2025-01-24T15:05:07.754590+07:00 PPL404I-112 CLI-admin[7365]:
CLI/status/log0_trace -n 205
2025-01-24T15:08:00.598561+07:00 PPL404I-112 crond[2683]: USER root pid 31107
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-24T15:23:39.541509+07:00 PPL404I-112 dropbear[7365]: Exit (admin) from
<192.168.99.55:61016>: Keepalive timeout
2025-01-24T15:31:07.351172+07:00 PPL404I-112 dropbear[30426]: Child connection
from 192.168.99.55:64486
2025-01-24T15:31:10.120047+07:00 PPL404I-112 dropbear[30426]: Password auth
succeeded for 'admin' from 192.168.99.55:64486
2025-01-24T15:31:12.415250+07:00 PPL404I-112 CLI-admin[30426]: CLI
2025-01-24T15:31:12.501331+07:00 PPL404I-112 CLI-admin[30426]: CLI/status
2025-01-24T15:31:14.582880+07:00 PPL404I-112 CLI-admin[30426]:
CLI/status/log0_trace -n 2500
2025-01-24T15:38:34.924819+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T15:38:34.925831+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T15:38:35.931891+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T15:38:35.931978+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T15:38:37.604198+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T15:38:38.278417+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T15:38:38.279257+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T15:38:38.286308+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T15:38:38.286390+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T15:38:39.941397+07:00 PPL404I-112 dropbear[30426]: Exit (admin) from
<192.168.99.55:64486>: Error reading: Connection reset by peer
2025-01-24T15:38:40.968390+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T15:38:57.321025+07:00 PPL404I-112 dropbear[9062]: Child connection
from 192.168.99.55:64148
2025-01-24T15:38:59.860847+07:00 PPL404I-112 dropbear[9062]: Password auth
succeeded for 'admin' from 192.168.99.55:64148
2025-01-24T15:39:02.483823+07:00 PPL404I-112 CLI-admin[9062]: CLI
2025-01-24T15:39:02.558417+07:00 PPL404I-112 CLI-admin[9062]: CLI/status
2025-01-24T15:39:02.573926+07:00 PPL404I-112 CLI-admin[9062]:
CLI/status/log0_trace -n 205
2025-01-24T15:44:44.993185+07:00 PPL404I-112 dropbear[16935]: Child connection
from 192.168.99.55:65021
2025-01-24T15:44:46.446129+07:00 PPL404I-112 dropbear[16935]: Password auth
succeeded for 'root' from 192.168.99.55:65021
2025-01-24T16:05:48.642813+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is down
2025-01-24T16:05:48.643454+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is down
2025-01-24T16:05:49.316328+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-24T16:05:49.691809+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is down
2025-01-24T16:05:49.691891+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity loss
2025-01-24T16:05:50.647867+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-24T16:05:50.648737+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-24T16:05:50.655749+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-24T16:05:50.655831+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-24T16:05:52.569708+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-24T16:08:00.648079+07:00 PPL404I-112 crond[2683]: USER root pid 16926
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-24T16:14:13.488978+07:00 PPL404I-112 upsd-usbd[5427]: Data for UPS
[pcmusb] is stale - check driver
2025-01-24T16:14:14.670026+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-24T16:14:14.699493+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-24T16:14:14.781976+07:00 PPL404I-112 upsd-usbd[5427]: Can't connect
to UPS [pcmusb] (blazer_usb-pcmusb): Connection refused
2025-01-24T16:14:15.785517+07:00 PPL404I-112 blazer_usb[25528]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2025-01-24T16:14:15.997890+07:00 PPL404I-112 blazer_usb[25528]: Supported UPS
detected with megatec protocol
2025-01-24T16:14:16.341499+07:00 PPL404I-112 blazer_usb[25528]: Vendor
information read in 1 tries
2025-01-24T16:14:16.693473+07:00 PPL404I-112 blazer_usb[25528]: Warning
information read in 1 tries
2025-01-24T16:14:17.037702+07:00 PPL404I-112 blazer_usb[25528]: Faultinfo
information read in 1 tries
2025-01-24T16:14:17.037800+07:00 PPL404I-112 blazer_usb[25528]: No values
provided for battery high/low voltages in ups.conf
2025-01-24T16:14:17.037957+07:00 PPL404I-112 blazer_usb[25528]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2025-01-24T16:14:17.038033+07:00 PPL404I-112 blazer_usb[25528]: Battery runtime
will not be calculated (runtimecal not set)
2025-01-24T16:14:17.213581+07:00 PPL404I-112 blazer_usb[25528]: Battery
information read in 1 tries
2025-01-24T16:14:18.776386+07:00 PPL404I-112 blazer_usb[25579]: Startup
successful
2025-01-24T16:14:18.786024+07:00 PPL404I-112 upsd-usbd[5427]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2025-01-24T16:14:20.405533+07:00 PPL404I-112 blazer_usb[25579]: sock_connect:
enabling asynchronous mode (auto)
2025-01-24T16:44:28.538618+07:00 PPL404I-112 CLI-admin[9062]:
CLI/status/log0_trace -n 2500 | grep check
2025-01-24T16:55:42.094001+07:00 PPL404I-112 dropbear[17756]: Child connection
from 192.168.99.55:52702
2025-01-24T16:55:42.642396+07:00 PPL404I-112 dropbear[17756]: Password auth
succeeded for 'root' from 192.168.99.55:52702
2025-01-24T16:56:17.480966+07:00 PPL404I-112 dropbear[4402]: Exit (root) from
<192.168.99.55:49224>: Error reading: Connection reset by peer
2025-01-24T16:56:22.858238+07:00 PPL404I-112 dropbear[18705]: Child connection
from 192.168.99.55:52728
2025-01-24T16:56:25.368052+07:00 PPL404I-112 dropbear[18705]: Password auth
succeeded for 'admin' from 192.168.99.55:52728
2025-01-24T16:56:27.972648+07:00 PPL404I-112 CLI-admin[18705]: CLI
2025-01-24T16:56:30.226945+07:00 PPL404I-112 dropbear[18866]: Child connection
from 192.168.99.55:52730
2025-01-24T16:56:32.977096+07:00 PPL404I-112 dropbear[18866]: Password auth
succeeded for 'root' from 192.168.99.55:52730
2025-01-24T17:00:16.618293+07:00 PPL404I-112 upsd-usbd[5427]: Data for UPS
[pcmusb] is stale - check driver
2025-01-24T17:00:17.887306+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-24T17:00:17.909707+07:00 PPL404I-112 dropbear[17255]: Exit (root) from
<192.168.99.55:52686>: Error reading: Connection reset by peer
2025-01-24T17:00:17.951576+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-24T17:00:18.058066+07:00 PPL404I-112 upsd-usbd[5427]: Can't connect
to UPS [pcmusb] (blazer_usb-pcmusb): Connection refused
2025-01-24T17:00:19.056079+07:00 PPL404I-112 blazer_usb[24325]: Please note that
this driver is deprecated and will not receive#012new development. If it works
for managing your devices - fine,#012but if you are running it to try setting up
a new device, please#012consider the newer nutdrv_qx instead, which should
handle all 'Qx'#012protocol variants for NUT. (Please also report if
your device works#012with this driver, but nutdrv_qx would not actually support
it with#012any subdriver!)
2025-01-24T17:00:19.493815+07:00 PPL404I-112 blazer_usb[24325]: Supported UPS
detected with megatec protocol
2025-01-24T17:00:19.965476+07:00 PPL404I-112 blazer_usb[24325]: Vendor
information read in 1 tries
2025-01-24T17:00:20.173477+07:00 PPL404I-112 blazer_usb[24325]: Warning
information read in 1 tries
2025-01-24T17:00:20.519541+07:00 PPL404I-112 blazer_usb[24325]: Faultinfo
information read in 1 tries
2025-01-24T17:00:20.519638+07:00 PPL404I-112 blazer_usb[24325]: No values
provided for battery high/low voltages in ups.conf
2025-01-24T17:00:20.519797+07:00 PPL404I-112 blazer_usb[24325]: Using
'guestimation' (low: 31.200000, high: 39.000000)!
2025-01-24T17:00:20.519876+07:00 PPL404I-112 blazer_usb[24325]: Battery runtime
will not be calculated (runtimecal not set)
2025-01-24T17:00:20.829567+07:00 PPL404I-112 blazer_usb[24325]: Battery
information read in 1 tries
2025-01-24T17:00:22.296338+07:00 PPL404I-112 blazer_usb[24376]: Startup
successful
2025-01-24T17:00:24.063642+07:00 PPL404I-112 upsd-usbd[5427]: Connected to UPS
[pcmusb]: blazer_usb-pcmusb
2025-01-24T17:00:24.065283+07:00 PPL404I-112 blazer_usb[24376]: sock_connect:
enabling asynchronous mode (auto)
2025-01-24T17:08:00.699430+07:00 PPL404I-112 crond[2683]: USER root pid 2544 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-24T17:10:35.862769+07:00 PPL404I-112 CLI-admin[18705]: CLI/status
2025-01-24T17:10:37.382695+07:00 PPL404I-112 CLI-admin[18705]:
CLI/status/log0_trace -n 205
2025-01-24T17:17:27.323280+07:00 PPL404I-112 CLI-admin[18705]:
CLI/status/log0_trace -n 205
2025-01-24T17:18:25.177001+07:00 PPL404I-112 dropbear[17756]: Exit (root) from
<192.168.99.55:52702>: Exited normally
2025-01-24T17:18:31.355819+07:00 PPL404I-112 dropbear[17291]: Child connection
from 192.168.99.55:63690
2025-01-24T17:18:31.715204+07:00 PPL404I-112 dropbear[17291]: Password auth
succeeded for 'root' from 192.168.99.55:63690
-------------- next part --------------
2025-01-29T16:56:32.000000+07:00 PPL404I-112 boot[904] ********************* PWR
logger-Power Up(syslog) *******************
2025-01-29T16:57:01.629623+07:00 PPL404I-112 : [origin
software="rsyslogd" swVersion="8.2110.0"
x-pid="2343" x-info="https://www.rsyslog.com"] start
2025-01-29T16:57:05.917969+07:00 PPL404I-112 root: /opt/pp/CLI/sbin/pre_zl502.sh
2025-01-29T16:57:10.177990+07:00 PPL404I-112 root: service QoS Stop ...
2025-01-29T16:57:10.569591+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2025-01-29T16:57:11.435186+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN4 link up
2025-01-29T16:57:11.705109+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN3 link down
2025-01-29T16:57:11.837841+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-29T16:57:11.968921+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN1 link down
2025-01-29T16:57:12.088005+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: wan link up
2025-01-29T16:57:14.287972+07:00 PPL404I-112 root:
/opt/pp/CLI/sbin/post_zl502.sh
2025-01-29T16:57:14.786295+07:00 PPL404I-112 netifd: Interface 'lan' is
enabled
2025-01-29T16:57:14.806437+07:00 PPL404I-112 netifd: Interface 'lan' is
now up
2025-01-29T16:57:14.812078+07:00 PPL404I-112 netifd: bridge 'br-lan'
link is up
2025-01-29T16:57:14.832910+07:00 PPL404I-112 netifd: Interface 'lan' has
link connectivity
2025-01-29T16:57:15.518085+07:00 PPL404I-112 root: service iptables Stop ...
2025-01-29T16:57:21.384669+07:00 PPL404I-112 procd: - init complete -
2025-01-29T16:57:22.599863+07:00 PPL404I-112 root: service QoS Stop ...
2025-01-29T16:57:23.030891+07:00 PPL404I-112 root: [serial_upsd]...Stopped
2025-01-29T16:57:27.767963+07:00 PPL404I-112 root: [usb_upsd]...Stopped
2025-01-29T16:57:28.028640+07:00 PPL404I-112 root: service iptables Stop ...
2025-01-29T16:57:29.608181+07:00 PPL404I-112 root: service iptables Starting ...
2025-01-29T16:57:38.498806+07:00 PPL404I-112 netifd: VLAN 'eth0.1' link
is up
2025-01-29T16:57:38.619843+07:00 PPL404I-112 netifd: Interface
'loopback' is enabled
2025-01-29T16:57:38.705448+07:00 PPL404I-112 netifd: Interface
'loopback' is now up
2025-01-29T16:57:38.730212+07:00 PPL404I-112 netifd: Interface 'wan' is
enabled
2025-01-29T16:57:38.744839+07:00 PPL404I-112 netifd: Interface 'wan' is
now up
2025-01-29T16:57:39.115236+07:00 PPL404I-112 netifd: Interface
'loopback' has link connectivity
2025-01-29T16:57:39.119386+07:00 PPL404I-112 netifd: VLAN 'eth0.2' link
is up
2025-01-29T16:57:39.183022+07:00 PPL404I-112 netifd: Interface 'wan' has
link connectivity
2025-01-29T16:57:39.221158+07:00 PPL404I-112 root: [nut-server-usb]...Stopped
2025-01-29T16:57:39.358038+07:00 PPL404I-112 root: [usb_upsd]...Started
2025-01-29T16:57:45.827626+07:00 PPL404I-112 dropbear[4943]: Child connection
from 172.31.1.55:49918
2025-01-29T16:57:50.826266+07:00 PPL404I-112 dnsmasq[5076]: started, version
2.89 cachesize 150
2025-01-29T16:57:50.832993+07:00 PPL404I-112 dnsmasq[5076]: DNS service limited
to local subnets
2025-01-29T16:57:50.838236+07:00 PPL404I-112 dnsmasq[5076]: UBus support
enabled: connected to system bus
2025-01-29T16:57:50.840174+07:00 PPL404I-112 dnsmasq-dhcp[5076]: DHCP, IP range
192.168.99.200 -- 192.168.99.249, lease time 12h
2025-01-29T16:57:50.842287+07:00 PPL404I-112 dnsmasq[5076]: using nameserver
1.1.1.1#53
2025-01-29T16:57:50.846608+07:00 PPL404I-112 dnsmasq[5076]: using nameserver
8.8.8.8#53
2025-01-29T16:57:50.871622+07:00 PPL404I-112 dnsmasq[5076]: read /etc/hosts - 12
names
2025-01-29T16:57:50.873657+07:00 PPL404I-112 dnsmasq[5076]: read
/tmp/hosts/dhcp.cfg01411c - 2 names
2025-01-29T16:57:51.309040+07:00 PPL404I-112 dnsmasq-dhcp[5076]: read
/etc/ethers - 0 addresses
2025-01-29T16:57:54.178483+07:00 PPL404I-112 hostapd: ACS: Automatic channel
selection started, this may take a bit
2025-01-29T16:57:54.197505+07:00 PPL404I-112 hostapd: wlan0: interface state
UNINITIALIZED->ACS
2025-01-29T16:57:54.200482+07:00 PPL404I-112 hostapd: wlan0: ACS-STARTED
2025-01-29T16:57:55.790047+07:00 PPL404I-112 netifd: Wireless device
'radio0' is now up
2025-01-29T16:57:56.224521+07:00 PPL404I-112 hostapd: wlan0: ACS-COMPLETED
freq=2437 channel=6
2025-01-29T16:57:59.055982+07:00 PPL404I-112 dropbear[4943]: Password auth
succeeded for 'admin' from 172.31.1.55:49918
2025-01-29T16:57:59.987649+07:00 PPL404I-112 hostapd: wlan0: interface state
ACS->ENABLED
2025-01-29T16:57:59.989133+07:00 PPL404I-112 hostapd: wlan0: AP-ENABLED
2025-01-29T16:58:01.485111+07:00 PPL404I-112 dropbear[5400]: Child connection
from 192.168.99.55:50572
2025-01-29T16:58:03.085291+07:00 PPL404I-112 root: [nut-server-usb]...Stopped
2025-01-29T16:58:06.683281+07:00 PPL404I-112 nutdrv_qx[5434]: device.serial: UPS
reported a non-significant serial [0000000000000000]
2025-01-29T16:58:39.990101+07:00 PPL404I-112 ntpdate[5052]: step time server
202.28.116.236 offset +32.624395 sec
2025-01-29T16:58:40.555852+07:00 PPL404I-112 nutdrv_qx[5434]: battery_number: 3
2025-01-29T16:58:40.555958+07:00 PPL404I-112 nutdrv_qx[5434]: battery_number,
settable range: 1..9
2025-01-29T16:58:40.886013+07:00 PPL404I-112 dropbear[5400]: Password auth
succeeded for 'admin' from 192.168.99.55:50572
2025-01-29T16:58:41.308906+07:00 PPL404I-112 nutdrv_qx[5434]: bypass_alarm:
enabled
2025-01-29T16:58:41.310345+07:00 PPL404I-112 nutdrv_qx[5434]: battery_alarm:
enabled
2025-01-29T16:58:41.311708+07:00 PPL404I-112 nutdrv_qx[5434]: bypass_when_off:
enabled
2025-01-29T16:58:41.313463+07:00 PPL404I-112 nutdrv_qx[5434]: alarm_control:
enabled
2025-01-29T16:58:41.313869+07:00 PPL404I-112 nutdrv_qx[5434]: converter_mode:
disabled
2025-01-29T16:58:41.316781+07:00 PPL404I-112 nutdrv_qx[5434]: eco_mode: enabled
2025-01-29T16:58:41.319161+07:00 PPL404I-112 nutdrv_qx[5434]: bypass_forbidding:
disabled
2025-01-29T16:58:41.319661+07:00 PPL404I-112 nutdrv_qx[5434]:
site_fault_detection: disabled
2025-01-29T16:58:41.875732+07:00 PPL404I-112 nutdrv_qx[5434]: max_bypass_volt:
264
2025-01-29T16:58:41.875916+07:00 PPL404I-112 nutdrv_qx[5434]: max_bypass_volt,
settable range: 230..264
2025-01-29T16:58:41.876059+07:00 PPL404I-112 nutdrv_qx[5434]: min_bypass_volt:
170
2025-01-29T16:58:41.876236+07:00 PPL404I-112 nutdrv_qx[5434]: min_bypass_volt,
settable range: 170..220
2025-01-29T16:58:42.019747+07:00 PPL404I-112 nutdrv_qx[5434]: max_bypass_freq:
53.0
2025-01-29T16:58:42.019892+07:00 PPL404I-112 nutdrv_qx[5434]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-29T16:58:42.020065+07:00 PPL404I-112 nutdrv_qx[5434]: min_bypass_freq:
47.0
2025-01-29T16:58:42.020183+07:00 PPL404I-112 nutdrv_qx[5434]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-29T16:58:42.772368+07:00 PPL404I-112 root: [nut-driver-usb]...Started
2025-01-29T16:58:42.774061+07:00 PPL404I-112 nutdrv_qx[5561]: Startup successful
2025-01-29T16:58:42.927967+07:00 PPL404I-112 upsd-usbd[5563]: listening on
127.0.0.1 port 6490
2025-01-29T16:58:42.934666+07:00 PPL404I-112 upsd-usbd[5563]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-29T16:58:43.227964+07:00 PPL404I-112 nutdrv_qx[5561]: sock_connect:
enabling asynchronous mode (auto)
2025-01-29T16:58:43.274554+07:00 PPL404I-112 root: [nut-server-usb]...Started
2025-01-29T16:58:43.276208+07:00 PPL404I-112 upsd-usbd[5564]: Startup successful
2025-01-29T16:58:45.296251+07:00 PPL404I-112 CLI-admin[4943]: CLI
2025-01-29T16:58:46.495327+07:00 PPL404I-112 CLI-admin[5400]: CLI
2025-01-29T16:58:54.471281+07:00 PPL404I-112 u_main.pl: Uupsd:Current
load='0' vs Threshold='50'
2025-01-29T16:58:54.476052+07:00 PPL404I-112 u_main.pl: Uupsd:Current
Battery_MinuteRemaining='2' vs Threshold='252'
2025-01-29T16:58:54.486509+07:00 PPL404I-112 u_main.pl: Uupsd:Current
temperature='22.2' vs Threshold='50'
2025-01-29T16:58:54.632381+07:00 PPL404I-112 u_main.pl:
Uupsd:Start-Service:AC-Status=0:UPS-Status=OL:Manual-Shutdown=0:Beeper=enabled
2025-01-29T16:58:54.647789+07:00 PPL404I-112 u_main.pl:
Uupsd:UPS-Beeper=>Enable
2025-01-29T16:58:55.539950+07:00 PPL404I-112 hu_sys.pl:
Uupsd:Syslog_Interval=300
2025-01-29T17:02:22.922171+07:00 PPL404I-112 CLI-admin[7813]: CLI/status/ups_cmd
127.0.0.1 1621 .1.3.6.1.2.1.33.1.1.27=1
2025-01-29T17:02:23.233300+07:00 PPL404I-112 u_main.pl:
Uupsd:RECEIVED-Test-Battery-10s
2025-01-29T17:02:23.419863+07:00 PPL404I-112 nutdrv_qx[5561]:
instcmd(test.battery.start.quick, [NULL])
2025-01-29T17:02:23.491675+07:00 PPL404I-112 nutdrv_qx[5561]: instcmd: SUCCEED
2025-01-29T17:02:26.163747+07:00 PPL404I-112 nutdrv_qx[5561]: battery_number: 3
2025-01-29T17:02:26.924224+07:00 PPL404I-112 nutdrv_qx[5561]: bypass_alarm:
enabled
2025-01-29T17:02:26.924356+07:00 PPL404I-112 nutdrv_qx[5561]: battery_alarm:
enabled
2025-01-29T17:02:26.924465+07:00 PPL404I-112 nutdrv_qx[5561]: bypass_when_off:
enabled
2025-01-29T17:02:26.924748+07:00 PPL404I-112 nutdrv_qx[5561]: alarm_control:
enabled
2025-01-29T17:02:26.924863+07:00 PPL404I-112 nutdrv_qx[5561]: converter_mode:
disabled
2025-01-29T17:02:26.925295+07:00 PPL404I-112 nutdrv_qx[5561]: eco_mode: enabled
2025-01-29T17:02:26.925455+07:00 PPL404I-112 nutdrv_qx[5561]: bypass_forbidding:
disabled
2025-01-29T17:02:26.925574+07:00 PPL404I-112 nutdrv_qx[5561]:
site_fault_detection: disabled
2025-01-29T17:02:27.515590+07:00 PPL404I-112 nutdrv_qx[5561]: max_bypass_volt:
264
2025-01-29T17:02:27.517010+07:00 PPL404I-112 nutdrv_qx[5561]: min_bypass_volt:
170
2025-01-29T17:02:27.651641+07:00 PPL404I-112 nutdrv_qx[5561]: max_bypass_freq:
53.0
2025-01-29T17:02:27.653076+07:00 PPL404I-112 nutdrv_qx[5561]: min_bypass_freq:
47.0
2025-01-29T17:02:29.667908+07:00 PPL404I-112 u_main.pl:
Uupsd:Current-BatteryMinuteRemaining=>Alert:2
2025-01-29T17:02:29.759342+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Test_Inprogress:Start=2025-01-29
17-02-29:End=:AC-Status=0:UPS-Status=OL
CAL:Load=0:Battery-Charge=100:Battery-Volt=40.60:Battery-Capacity=99:Battery-Remaining-Time=2
2025-01-29T17:02:36.636909+07:00 PPL404I-112 u_main.pl:
Uupsd:Test-Battery-10s=>Done:Start=2025-01-29 17-02-29:End=2025-01-29
17-02-36:AC-Status=0:UPS-Status=OL:Load=0:Battery-Charge=100:Battery-Volt=40.60:Battery-Capacity=99:Battery-Remaining-Time=2
2025-01-29T17:04:51.487783+07:00 PPL404I-112 CLI-admin[5400]:
CLI/status/running_config | grep ups
2025-01-29T17:05:16.600257+07:00 PPL404I-112 CLI-admin[5400]:
CLI/status/log0_trace -n 205
2025-01-29T17:05:48.131897+07:00 PPL404I-112 dropbear[24070]: Child connection
from 192.168.99.55:64729
2025-01-29T17:05:50.926744+07:00 PPL404I-112 dropbear[24070]: Password auth
succeeded for 'root' from 192.168.99.55:64729
2025-01-29T17:07:30.054760+07:00 PPL404I-112 CLI-admin[5400]:
CLI/status/log0_trace -n 250
2025-01-29T17:08:00.718143+07:00 PPL404I-112 crond[2480]: USER root pid 26740
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-29T18:08:00.770033+07:00 PPL404I-112 crond[2480]: USER root pid 7558 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-29T19:08:00.819400+07:00 PPL404I-112 crond[2480]: USER root pid 20554
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-29T20:08:00.868970+07:00 PPL404I-112 crond[2480]: USER root pid 880 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-29T21:08:00.919810+07:00 PPL404I-112 crond[2480]: USER root pid 12389
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-29T22:08:00.969307+07:00 PPL404I-112 crond[2480]: USER root pid 23754
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-29T23:08:00.015795+07:00 PPL404I-112 crond[2480]: USER root pid 2184 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T00:08:00.061887+07:00 PPL404I-112 crond[2480]: USER root pid 12687
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T00:08:16.038500+07:00 PPL404I-112 ntpdate[12742]: step time server
202.28.116.236 offset +0.145794 sec
2025-01-30T01:08:00.253699+07:00 PPL404I-112 crond[2480]: USER root pid 23383
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T01:19:10.921187+07:00 PPL404I-112 upsd-usbd[5564]: Data for UPS
[pcmusb] is stale - check driver
2025-01-30T01:19:12.378439+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-30T01:19:12.481222+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-30T01:19:12.634689+07:00 PPL404I-112 upsd-usbd[5564]: Can't connect
to UPS [pcmusb] (nutdrv_qx-pcmusb): Connection refused
2025-01-30T01:19:15.405366+07:00 PPL404I-112 nutdrv_qx[5649]: device.serial: UPS
reported a non-significant serial [0000000000000000]
2025-01-30T01:19:16.597616+07:00 PPL404I-112 nutdrv_qx[5649]: battery_number: 3
2025-01-30T01:19:16.599142+07:00 PPL404I-112 nutdrv_qx[5649]: battery_number,
settable range: 1..9
2025-01-30T01:19:17.230718+07:00 PPL404I-112 nutdrv_qx[5649]: bypass_alarm:
enabled
2025-01-30T01:19:17.232143+07:00 PPL404I-112 nutdrv_qx[5649]: battery_alarm:
enabled
2025-01-30T01:19:17.233595+07:00 PPL404I-112 nutdrv_qx[5649]: bypass_when_off:
enabled
2025-01-30T01:19:17.235349+07:00 PPL404I-112 nutdrv_qx[5649]: alarm_control:
enabled
2025-01-30T01:19:17.236752+07:00 PPL404I-112 nutdrv_qx[5649]: converter_mode:
disabled
2025-01-30T01:19:17.238724+07:00 PPL404I-112 nutdrv_qx[5649]: eco_mode: enabled
2025-01-30T01:19:17.240222+07:00 PPL404I-112 nutdrv_qx[5649]: bypass_forbidding:
disabled
2025-01-30T01:19:17.240608+07:00 PPL404I-112 nutdrv_qx[5649]:
site_fault_detection: disabled
2025-01-30T01:19:17.821395+07:00 PPL404I-112 nutdrv_qx[5649]: max_bypass_volt:
264
2025-01-30T01:19:17.822850+07:00 PPL404I-112 nutdrv_qx[5649]: max_bypass_volt,
settable range: 230..264
2025-01-30T01:19:17.824401+07:00 PPL404I-112 nutdrv_qx[5649]: min_bypass_volt:
170
2025-01-30T01:19:17.825808+07:00 PPL404I-112 nutdrv_qx[5649]: min_bypass_volt,
settable range: 170..220
2025-01-30T01:19:17.957421+07:00 PPL404I-112 nutdrv_qx[5649]: max_bypass_freq:
53.0
2025-01-30T01:19:17.957952+07:00 PPL404I-112 nutdrv_qx[5649]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-30T01:19:17.960475+07:00 PPL404I-112 nutdrv_qx[5649]: min_bypass_freq:
47.0
2025-01-30T01:19:17.960869+07:00 PPL404I-112 nutdrv_qx[5649]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-30T01:19:18.848576+07:00 PPL404I-112 nutdrv_qx[5687]: Startup successful
2025-01-30T01:19:20.643220+07:00 PPL404I-112 upsd-usbd[5564]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-30T01:19:20.643474+07:00 PPL404I-112 nutdrv_qx[5687]: sock_connect:
enabling asynchronous mode (auto)
2025-01-30T01:30:13.583793+07:00 PPL404I-112 upsd-usbd[5564]: Data for UPS
[pcmusb] is stale - check driver
2025-01-30T01:30:13.602950+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-30T01:30:13.633245+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-30T01:30:13.717263+07:00 PPL404I-112 upsd-usbd[5564]: Can't connect
to UPS [pcmusb] (nutdrv_qx-pcmusb): Connection refused
2025-01-30T01:30:16.533400+07:00 PPL404I-112 nutdrv_qx[19405]: device.serial:
UPS reported a non-significant serial [0000000000000000]
2025-01-30T01:30:17.150642+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN4 link up
2025-01-30T01:30:17.813613+07:00 PPL404I-112 nutdrv_qx[19405]: battery_number: 3
2025-01-30T01:30:17.814981+07:00 PPL404I-112 nutdrv_qx[19405]: battery_number,
settable range: 1..9
2025-01-30T01:30:18.430711+07:00 PPL404I-112 nutdrv_qx[19405]: bypass_alarm:
enabled
2025-01-30T01:30:18.432148+07:00 PPL404I-112 nutdrv_qx[19405]: battery_alarm:
enabled
2025-01-30T01:30:18.433713+07:00 PPL404I-112 nutdrv_qx[19405]: bypass_when_off:
enabled
2025-01-30T01:30:18.435483+07:00 PPL404I-112 nutdrv_qx[19405]: alarm_control:
enabled
2025-01-30T01:30:18.437022+07:00 PPL404I-112 nutdrv_qx[19405]: converter_mode:
disabled
2025-01-30T01:30:18.438942+07:00 PPL404I-112 nutdrv_qx[19405]: eco_mode: enabled
2025-01-30T01:30:18.439442+07:00 PPL404I-112 nutdrv_qx[19405]:
bypass_forbidding: disabled
2025-01-30T01:30:18.441856+07:00 PPL404I-112 nutdrv_qx[19405]:
site_fault_detection: disabled
2025-01-30T01:30:19.005439+07:00 PPL404I-112 nutdrv_qx[19405]: max_bypass_volt:
264
2025-01-30T01:30:19.006899+07:00 PPL404I-112 nutdrv_qx[19405]: max_bypass_volt,
settable range: 230..264
2025-01-30T01:30:19.008357+07:00 PPL404I-112 nutdrv_qx[19405]: min_bypass_volt:
170
2025-01-30T01:30:19.009776+07:00 PPL404I-112 nutdrv_qx[19405]: min_bypass_volt,
settable range: 170..220
2025-01-30T01:30:19.141486+07:00 PPL404I-112 nutdrv_qx[19405]: max_bypass_freq:
53.0
2025-01-30T01:30:19.141629+07:00 PPL404I-112 nutdrv_qx[19405]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-30T01:30:19.141803+07:00 PPL404I-112 nutdrv_qx[19405]: min_bypass_freq:
47.0
2025-01-30T01:30:19.141920+07:00 PPL404I-112 nutdrv_qx[19405]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-30T01:30:19.952580+07:00 PPL404I-112 nutdrv_qx[19446]: Startup
successful
2025-01-30T01:30:21.725439+07:00 PPL404I-112 upsd-usbd[5564]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-30T01:30:21.725692+07:00 PPL404I-112 nutdrv_qx[19446]: sock_connect:
enabling asynchronous mode (auto)
2025-01-30T01:54:18.753041+07:00 PPL404I-112 upsd-usbd[5564]: Data for UPS
[pcmusb] is stale - check driver
2025-01-30T01:54:20.190499+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-30T01:54:20.252101+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-30T01:54:20.388372+07:00 PPL404I-112 upsd-usbd[5564]: Can't connect
to UPS [pcmusb] (nutdrv_qx-pcmusb): Connection refused
2025-01-30T01:54:23.333384+07:00 PPL404I-112 nutdrv_qx[17716]: device.serial:
UPS reported a non-significant serial [0000000000000000]
2025-01-30T01:54:24.509598+07:00 PPL404I-112 nutdrv_qx[17716]: battery_number: 3
2025-01-30T01:54:24.510943+07:00 PPL404I-112 nutdrv_qx[17716]: battery_number,
settable range: 1..9
2025-01-30T01:54:25.278698+07:00 PPL404I-112 nutdrv_qx[17716]: bypass_alarm:
enabled
2025-01-30T01:54:25.280109+07:00 PPL404I-112 nutdrv_qx[17716]: battery_alarm:
enabled
2025-01-30T01:54:25.281461+07:00 PPL404I-112 nutdrv_qx[17716]: bypass_when_off:
enabled
2025-01-30T01:54:25.283254+07:00 PPL404I-112 nutdrv_qx[17716]: alarm_control:
enabled
2025-01-30T01:54:25.284652+07:00 PPL404I-112 nutdrv_qx[17716]: converter_mode:
disabled
2025-01-30T01:54:25.286940+07:00 PPL404I-112 nutdrv_qx[17716]: eco_mode: enabled
2025-01-30T01:54:25.288525+07:00 PPL404I-112 nutdrv_qx[17716]:
bypass_forbidding: disabled
2025-01-30T01:54:25.288897+07:00 PPL404I-112 nutdrv_qx[17716]:
site_fault_detection: disabled
2025-01-30T01:54:25.709431+07:00 PPL404I-112 nutdrv_qx[17716]: max_bypass_volt:
264
2025-01-30T01:54:25.710861+07:00 PPL404I-112 nutdrv_qx[17716]: max_bypass_volt,
settable range: 230..264
2025-01-30T01:54:25.712361+07:00 PPL404I-112 nutdrv_qx[17716]: min_bypass_volt:
170
2025-01-30T01:54:25.713857+07:00 PPL404I-112 nutdrv_qx[17716]: min_bypass_volt,
settable range: 170..220
2025-01-30T01:54:25.989422+07:00 PPL404I-112 nutdrv_qx[17716]: max_bypass_freq:
53.0
2025-01-30T01:54:25.989803+07:00 PPL404I-112 nutdrv_qx[17716]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-30T01:54:25.990284+07:00 PPL404I-112 nutdrv_qx[17716]: min_bypass_freq:
47.0
2025-01-30T01:54:25.993525+07:00 PPL404I-112 nutdrv_qx[17716]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-30T01:54:26.700544+07:00 PPL404I-112 nutdrv_qx[17754]: Startup
successful
2025-01-30T01:54:28.395427+07:00 PPL404I-112 upsd-usbd[5564]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-30T01:54:28.397038+07:00 PPL404I-112 nutdrv_qx[17754]: sock_connect:
enabling asynchronous mode (auto)
2025-01-30T02:01:00.297648+07:00 PPL404I-112 crond[2480]: USER root pid 25919
cmd run-parts /opt/pp/CLI/sbin/etc/cron.daily
2025-01-30T02:05:03.093080+07:00 PPL404I-112 : [origin
software="rsyslogd" swVersion="8.2110.0"
x-pid="2343" x-info="https://www.rsyslog.com"] rsyslogd was
HUPed
2025-01-30T02:08:00.304456+07:00 PPL404I-112 crond[2480]: USER root pid 2283 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T03:08:00.350284+07:00 PPL404I-112 crond[2480]: USER root pid 13312
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T04:08:00.395500+07:00 PPL404I-112 crond[2480]: USER root pid 24215
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T04:43:41.028658+07:00 PPL404I-112 upsd-usbd[5564]: Data for UPS
[pcmusb] is stale - check driver
2025-01-30T04:43:41.075539+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-30T04:43:41.144944+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-30T04:43:41.283605+07:00 PPL404I-112 upsd-usbd[5564]: Can't connect
to UPS [pcmusb] (nutdrv_qx-pcmusb): Connection refused
2025-01-30T04:43:44.277374+07:00 PPL404I-112 nutdrv_qx[4699]: device.serial: UPS
reported a non-significant serial [0000000000000000]
2025-01-30T04:43:45.453611+07:00 PPL404I-112 nutdrv_qx[4699]: battery_number: 3
2025-01-30T04:43:45.454973+07:00 PPL404I-112 nutdrv_qx[4699]: battery_number,
settable range: 1..9
2025-01-30T04:43:46.214688+07:00 PPL404I-112 nutdrv_qx[4699]: bypass_alarm:
enabled
2025-01-30T04:43:46.216116+07:00 PPL404I-112 nutdrv_qx[4699]: battery_alarm:
enabled
2025-01-30T04:43:46.217471+07:00 PPL404I-112 nutdrv_qx[4699]: bypass_when_off:
enabled
2025-01-30T04:43:46.219211+07:00 PPL404I-112 nutdrv_qx[4699]: alarm_control:
enabled
2025-01-30T04:43:46.220618+07:00 PPL404I-112 nutdrv_qx[4699]: converter_mode:
disabled
2025-01-30T04:43:46.222514+07:00 PPL404I-112 nutdrv_qx[4699]: eco_mode: enabled
2025-01-30T04:43:46.224090+07:00 PPL404I-112 nutdrv_qx[4699]: bypass_forbidding:
disabled
2025-01-30T04:43:46.224472+07:00 PPL404I-112 nutdrv_qx[4699]:
site_fault_detection: disabled
2025-01-30T04:43:46.773409+07:00 PPL404I-112 nutdrv_qx[4699]: max_bypass_volt:
264
2025-01-30T04:43:46.773587+07:00 PPL404I-112 nutdrv_qx[4699]: max_bypass_volt,
settable range: 230..264
2025-01-30T04:43:46.773722+07:00 PPL404I-112 nutdrv_qx[4699]: min_bypass_volt:
170
2025-01-30T04:43:46.773894+07:00 PPL404I-112 nutdrv_qx[4699]: min_bypass_volt,
settable range: 170..220
2025-01-30T04:43:46.909420+07:00 PPL404I-112 nutdrv_qx[4699]: max_bypass_freq:
53.0
2025-01-30T04:43:46.909821+07:00 PPL404I-112 nutdrv_qx[4699]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-30T04:43:46.910316+07:00 PPL404I-112 nutdrv_qx[4699]: min_bypass_freq:
47.0
2025-01-30T04:43:46.910654+07:00 PPL404I-112 nutdrv_qx[4699]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-30T04:43:47.628649+07:00 PPL404I-112 nutdrv_qx[4748]: Startup successful
2025-01-30T04:43:49.292661+07:00 PPL404I-112 upsd-usbd[5564]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-30T04:43:49.292955+07:00 PPL404I-112 nutdrv_qx[4748]: sock_connect:
enabling asynchronous mode (auto)
2025-01-30T05:08:00.441559+07:00 PPL404I-112 crond[2480]: USER root pid 3063 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T06:08:00.491364+07:00 PPL404I-112 crond[2480]: USER root pid 14514
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T07:08:00.536049+07:00 PPL404I-112 crond[2480]: USER root pid 26753
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T08:08:00.584456+07:00 PPL404I-112 crond[2480]: USER root pid 6113 cmd
run-parts /opt/pp/CLI/sbin/etc/cron.hourly
2025-01-30T08:43:17.965297+07:00 PPL404I-112 upsd-usbd[5564]: Data for UPS
[pcmusb] is stale - check driver
2025-01-30T08:43:19.359901+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-30T08:43:19.422231+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-30T08:43:19.564271+07:00 PPL404I-112 upsd-usbd[5564]: Can't connect
to UPS [pcmusb] (nutdrv_qx-pcmusb): Connection refused
2025-01-30T08:43:22.557374+07:00 PPL404I-112 nutdrv_qx[19246]: device.serial:
UPS reported a non-significant serial [0000000000000000]
2025-01-30T08:43:23.765612+07:00 PPL404I-112 nutdrv_qx[19246]: battery_number: 3
2025-01-30T08:43:23.766978+07:00 PPL404I-112 nutdrv_qx[19246]: battery_number,
settable range: 1..9
2025-01-30T08:43:24.543252+07:00 PPL404I-112 nutdrv_qx[19246]: bypass_alarm:
enabled
2025-01-30T08:43:24.544674+07:00 PPL404I-112 nutdrv_qx[19246]: battery_alarm:
enabled
2025-01-30T08:43:24.546035+07:00 PPL404I-112 nutdrv_qx[19246]: bypass_when_off:
enabled
2025-01-30T08:43:24.547799+07:00 PPL404I-112 nutdrv_qx[19246]: alarm_control:
enabled
2025-01-30T08:43:24.549196+07:00 PPL404I-112 nutdrv_qx[19246]: converter_mode:
disabled
2025-01-30T08:43:24.551103+07:00 PPL404I-112 nutdrv_qx[19246]: eco_mode: enabled
2025-01-30T08:43:24.552596+07:00 PPL404I-112 nutdrv_qx[19246]:
bypass_forbidding: disabled
2025-01-30T08:43:24.553053+07:00 PPL404I-112 nutdrv_qx[19246]:
site_fault_detection: disabled
2025-01-30T08:43:25.125411+07:00 PPL404I-112 nutdrv_qx[19246]: max_bypass_volt:
264
2025-01-30T08:43:25.126868+07:00 PPL404I-112 nutdrv_qx[19246]: max_bypass_volt,
settable range: 230..264
2025-01-30T08:43:25.128329+07:00 PPL404I-112 nutdrv_qx[19246]: min_bypass_volt:
170
2025-01-30T08:43:25.129740+07:00 PPL404I-112 nutdrv_qx[19246]: min_bypass_volt,
settable range: 170..220
2025-01-30T08:43:25.285444+07:00 PPL404I-112 nutdrv_qx[19246]: max_bypass_freq:
53.0
2025-01-30T08:43:25.286864+07:00 PPL404I-112 nutdrv_qx[19246]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-30T08:43:25.287303+07:00 PPL404I-112 nutdrv_qx[19246]: min_bypass_freq:
47.0
2025-01-30T08:43:25.287744+07:00 PPL404I-112 nutdrv_qx[19246]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-30T08:43:26.013652+07:00 PPL404I-112 nutdrv_qx[19316]: Startup
successful
2025-01-30T08:43:27.572294+07:00 PPL404I-112 upsd-usbd[5564]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-30T08:43:27.572522+07:00 PPL404I-112 nutdrv_qx[19316]: sock_connect:
enabling asynchronous mode (auto)
2025-01-30T08:43:58.363133+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-30T08:50:16.427930+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-30T08:56:57.509560+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-30T08:57:00.918761+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-30T08:57:04.340224+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-30T08:57:07.776708+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-30T08:57:11.240717+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-30T08:57:48.760184+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link down
2025-01-30T08:57:52.214808+07:00 PPL404I-112 root: rt3050-esw 10110000.esw: link
changed: LAN2 link up
2025-01-30T09:00:21.250190+07:00 PPL404I-112 upsd-usbd[5564]: Data for UPS
[pcmusb] is stale - check driver
2025-01-30T09:00:21.302316+07:00 PPL404I-112 u_main.pl: Uupsd: cannot get data
from ups retry:1/3
2025-01-30T09:00:21.372934+07:00 PPL404I-112 u_main.pl: Uupsd: Defined UPS's
USBVIDPID has been found:restore connection
2025-01-30T09:00:21.515464+07:00 PPL404I-112 upsd-usbd[5564]: Can't connect
to UPS [pcmusb] (nutdrv_qx-pcmusb): Connection refused
2025-01-30T09:00:24.213375+07:00 PPL404I-112 nutdrv_qx[8257]: device.serial: UPS
reported a non-significant serial [0000000000000000]
2025-01-30T09:00:25.373642+07:00 PPL404I-112 nutdrv_qx[8257]: battery_number: 3
2025-01-30T09:00:25.374988+07:00 PPL404I-112 nutdrv_qx[8257]: battery_number,
settable range: 1..9
2025-01-30T09:00:25.998721+07:00 PPL404I-112 nutdrv_qx[8257]: bypass_alarm:
enabled
2025-01-30T09:00:26.000129+07:00 PPL404I-112 nutdrv_qx[8257]: battery_alarm:
enabled
2025-01-30T09:00:26.001464+07:00 PPL404I-112 nutdrv_qx[8257]: bypass_when_off:
enabled
2025-01-30T09:00:26.003245+07:00 PPL404I-112 nutdrv_qx[8257]: alarm_control:
enabled
2025-01-30T09:00:26.004640+07:00 PPL404I-112 nutdrv_qx[8257]: converter_mode:
disabled
2025-01-30T09:00:26.006533+07:00 PPL404I-112 nutdrv_qx[8257]: eco_mode: enabled
2025-01-30T09:00:26.008002+07:00 PPL404I-112 nutdrv_qx[8257]: bypass_forbidding:
disabled
2025-01-30T09:00:26.008371+07:00 PPL404I-112 nutdrv_qx[8257]:
site_fault_detection: disabled
2025-01-30T09:00:26.549411+07:00 PPL404I-112 nutdrv_qx[8257]: max_bypass_volt:
264
2025-01-30T09:00:26.550831+07:00 PPL404I-112 nutdrv_qx[8257]: max_bypass_volt,
settable range: 230..264
2025-01-30T09:00:26.552269+07:00 PPL404I-112 nutdrv_qx[8257]: min_bypass_volt:
170
2025-01-30T09:00:26.553747+07:00 PPL404I-112 nutdrv_qx[8257]: min_bypass_volt,
settable range: 170..220
2025-01-30T09:00:26.685511+07:00 PPL404I-112 nutdrv_qx[8257]: max_bypass_freq:
53.0
2025-01-30T09:00:26.685894+07:00 PPL404I-112 nutdrv_qx[8257]: max_bypass_freq,
settable range: 51.0..60.0
2025-01-30T09:00:26.686376+07:00 PPL404I-112 nutdrv_qx[8257]: min_bypass_freq:
47.0
2025-01-30T09:00:26.686700+07:00 PPL404I-112 nutdrv_qx[8257]: min_bypass_freq,
settable range: 40.0..49.0
2025-01-30T09:00:27.513701+07:00 PPL404I-112 nutdrv_qx[8295]: Startup successful
2025-01-30T09:00:27.522277+07:00 PPL404I-112 upsd-usbd[5564]: Connected to UPS
[pcmusb]: nutdrv_qx-pcmusb
2025-01-30T09:00:27.829782+07:00 PPL404I-112 nutdrv_qx[8295]: sock_connect:
enabling asynchronous mode (auto)
2025-01-30T09:08:00.631083+07:00 PPL404I-112 crond[2480]: USER root pid 18057
cmd run-parts /opt/pp/CLI/sbin/etc/cron.hourly
Greg Troxel
2025-Jan-31 12:19 UTC
[Nut-upsdev] Error "Data for UPS [pcmusb] is stale - check driver"
"Rushabh Sanghavi (Rush)" <Rushabh at pp-ontime.co.th> writes:> * NUT Version 2.8.0-3 was installed on our 4G LTE WiFi router by our team.You have two problems right there. Most importantly, the most recent release of nut is 2.8.2, from April of 2024. 2.8.0 is from April of 2022. Many things have been fixed. I personally do not engage in troubleshooting out of date code. (There have also been fixes since 2.8.2; there are 1658 commits on master after the v2.8.2 tag.) Secondly, there is no nut version 2.8.0-3. That is almost certainly the version of a package provided by some packaging system. Therefore, my advice is to build current nut sources from git master and test those. Perhaps also 2.8.2.> Awaiting your swift response back.Perhaps you have a support contract with somebody (in which case this should ahve been sent to them and not the list), but assuming that's not true, please keep in mind that you have received software at no charge and now you are asking for help at no charge. Also, your email belonged on nut-upsuser instaed of nut-upsdev. I suggest you start over there after you have compiled and tested with up to date code.> Confidentiality: This Information is intended for the above-named > person and may contain confidential and/or legally privileged > material. Any opinions expressed in this information are not > necessarily those of the company. If it has come to you in error you > must take no action based on it, nor must you copy or show it to > anyone; please delete/destroy and inform the sender immediately.You've posted to a public list. Please fix your mail system so that you do not include nonsensical disclaimers and demands in such mail.
Ted Mittelstaedt
2025-Feb-02 18:18 UTC
[Nut-upsdev] Error "Data for UPS [pcmusb] is stale - check driver"
OpenWRT version 23.05.0-rc3 is, for starters, not supported anymore by the OpenWRT project, and is old. The current version is OpenWRT 23.05.05 The reason you are likely getting an old version of NUT when you load the nut package is because you are using an old version of openwrt. Your team needs to sysupdate your 4G LTE Wifi router You also, in my opinion, need to seriously reconsider running NUT on an openwrt router.? The reason why is that NUT generates logfiles and writes to the filesystem. The flash chips that are used on routers are not designed like a USB flash stick where they are intended to have a read/write filesystem on them.? They have no bad block management with NAND flash chips.? That is provided by a UBI layer.? You can read about that here: [OpenWrt Wiki] The OpenWrt Flash Layout <https://openwrt.org/docs/techref/flash.layout> SOME of the NAND devices that OpenWRT has been ported to, DO have complete UBI support, others don't.? You did not say what model of router you are running - but unless you have researched it and are completely sure that it has a fully functional bad block management, you can easily cause problems over time attempting to run programs on an OpenWRT router. In general it's safest to run READ ONLY programs on openwrt.? For example, the snmpd server.? Programs that WRITE to the filesystem on the OpenWRT router should be avoided. There's a reason we use hard drives on servers. Ted On 1/30/2025 7:50 PM, Rushabh Sanghavi (Rush) wrote:> > Dear NUT Developers, > > A very good morning to you and hope that you are in the best of health > and spirits. > > For an upcoming UPS Project, our team has been testing Powercom?s > Cleanline T-1500 UPS model whose photo has been attached with this > e-mail. Our team has been testing this UPS with one of our 4G LTE WiFi > router models on which Network UPS Tools (NUT) Version 2.8.0-3 has > been installed. BUT during the testing our team observed multiple > instances of error message *"Data for UPS [pcmusb] is stale - check > driver"* being randomly reported by our 4G LTE WiFi router. Here is > the SUMMARY of the issue below for clear understanding purposes. > > * NUT Version 2.8.0-3 was installed on our 4G LTE WiFi router by our > team. > * Also our 4G LTE WiFi router had Linux Kernel Version 5.15.127, > OpenWRT Distribution release ?23.05.0-rc3? and OpenWRT > Distribution Revision ?r23389-5deed175a5? installed on it. > * Powercom?s Cleanline T-1500 UPS was connected with our 4G LTE WiFi > router via USB to USB Cable Connection (i.e. USB Port on router > side and USB Port on UPS side) > > Now when NUT installed on our 4G LTE WiFi router model unit tried to > poll and fetch values of different UPS parameters from Powercom?s > Cleanline T-1500 UPS model > > after both UPS and router had been running for sometime (i.e. for > random period of time): > > o router started reporting the error message *?Data for UPS > [pcmusb] is stale - check driver?* > o after that router could not get UPS?s status any more unless > we restart the NUT service > o and the router started reporting the error message ?Data for > UPS [pcmusb] is stale - check driver? after running for > sometime again > > Note: *[pcmusb]* represents the *name or identifier* assigned to the > UPS instance within the NUT (Network UPS Tools) configuration > > * Our team tried to increase value of NUT?s timers such as > ?pollinterval?, ?pollfreq?, ?maxage? but still the issue could not > get solved or fixed > * Kindly NOTE that our team tested the above with both the NUT > Drivers i.e. blazer_usb and nutdrv_qx. But the same error message > mentioned above was observed. > * Also kindly NOTE that our team also tried to test with NUT Driver > ?usbhid-ups? but it is seems that this particular Driver is not > supported by Powercom?s Cleanline T-1500 UPS model whose photo has > been attached with this e-mail. > * Currently our team is not 100% sure about the exact root cause. > > Our team need to know the following from NUT Developers. > > * Which the is correct NUT Driver that our team need to use on the > 4G LTE WiFi router so that it can communicate smoothly and > successfully with Powercom?s Cleanline T-1500 UPS model whose > photo has been attached with this e-mail? > * Which specific parameters within the default Configuration > Settings file of NUT Version 2.8.0-3 on our 4G LTE WiFi router > need to be tweaked / changed so that our 4G LTE WiFi router model > can communicate with the Powercom?s Cleanline T-1500 UPS model > smoothly and successfully? > * Which specific parameters within the default ups.conf / upsd.conf > file on our 4G LTE WiFi router needs to be tweaked / changed so > that our 4G LTE WiFi router model can communicate with the > Powercom?s Cleanline T-1500 UPS model smoothly and successfully? > > Also I am hereby attaching the Log Files with the Log Messages > reported on our 4G LTE WiFi router model. The 1st Log file contains > Log Messages during testing with NUT Driver ?blazer_usb? while the 2nd > Log file contains Log Messages during testing with NUT Driver > ?nutdrv_qx?. You will observe the ERROR Message *?Data for UPS > [pcmusb] is stale - check driver?* within both these attached Log Files. > > Awaiting your swift response back. > > Thanking you, > > Yours sincerely, > > Legs Logo > > *Rushabh N. S*** > > *Research and Development Director* > > *PP Ontime Company Limited* > > *PP Group of Companies* > > Address: 1011 Supalai Grand Tower, > > 16th Floor, Rama 3 Road, > > Chongnonsi, Yannawa, > > Bangkok ? 10120, Thailand > > Landline No: +66-2-0562099 Ext. 2201 > > Fax No: +66-2-0562088 > > Cell Phone No: +66-8-59118578 / +66-6-22236221 > > E-mail: rushabh at pp-ontime.co.th <mailto:rushabh at pp-ontime.co.th> > > Web: www.pp-ontime.co.th <http://www.pp-ontime.co.th> > > Skype ID: rushabh.sanghavi > > *Disclaimer:* > > *************************************************************** > *Important* > Confidentiality: This Information is intended for the above-named > person and may contain confidential and/or legally privileged > material. Any opinions expressed in this information are not > necessarily those of the company. If it has come to you in error you > must take no action based on it, nor must you copy or show it to > anyone; please delete/destroy and inform the sender immediately. > > *Monitoring/Viruses/Malwares* > PP-Ontime reserves the right to monitor all incoming and outgoing > emails via PP-Ontime's systems. Although we have security program to > monitor and eliminate virus/malware, we also advise that in keeping > with good computing practice the recipient should ensure they are > actually virus/malwares free. > *************************************************************** > > > Disclaimer: > > *********************************************************************************************** > *Important* > Confidentiality: This Information is intended for the above-named > person and may contain confidential and/or legally privileged > material. Any opinions expressed in this information are not > necessarily those of the company. If it has come to you in error you > must take no action based on it, nor must you copy or show it to > anyone; please delete/destroy and inform the sender immediately. > *Monitoring/Viruses/Malwares* > PP-Ontime reserves the right to monitor all incoming and outgoing > emails via PP-Ontime's systems. Although we have security program to > monitor and eliminate virus/malware, we also advise that in keeping > with good computing practice the recipient should ensure they are > actually virus/malwares free. > ********************************************************************************************** > > > _______________________________________________ > Nut-upsdev mailing list > Nut-upsdev at alioth-lists.debian.net > https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/nut-upsdev-------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20250202/912b555b/attachment-0001.htm> -------------- next part -------------- A non-text attachment was scrubbed... Name: image001.jpg Type: image/jpeg Size: 4031 bytes Desc: not available URL: <http://alioth-lists.debian.net/pipermail/nut-upsdev/attachments/20250202/912b555b/attachment-0001.jpg>