Valentin N. Soloviov
2007-Jul-20 18:59 UTC
[Nut-upsdev] PowerCOM UPS management protocol specification
Hello All. I have PowerCOM ( http://pcmups.com.tw/ ) UPS management protocol specification at http://www.sovico.org/pcm.txt Current version of NUT contains any drivers include driver for Powercom, but not fully funcionality. This specification describe protocol for next series UPS: BLACK KNIGHT: All UPS AP series WARRIOR: WAR-1000AP WOW: All UPS U series IMPERIAL: All UPS KING: All UPS SMART KING: All UPS VANGUARD: All UPS ULTIMATE: All UPS ONLINE: All UPS Best, regards.
Carlos Rodrigues
2007-Jul-21 12:55 UTC
[Nut-upsdev] PowerCOM UPS management protocol specification
On 7/20/07, Valentin N. Soloviov <vvsa at newmail.ru> wrote:> Hello All. > > I have PowerCOM ( http://pcmups.com.tw/ ) UPS management protocol > specification at http://www.sovico.org/pcm.txtThat's the megatec protocol, supported by the "megatec" driver.> Current version of NUT contains any drivers include driver for > Powercom, but not fully funcionality.The only thing that the megatec doesn't seem to support from that protocol description is the "test for N seconds" command.> This specification describe protocol for next series UPS: > BLACK KNIGHT: All UPS AP series > WARRIOR: WAR-1000AP > WOW: All UPS U series > IMPERIAL: All UPS > KING: All UPS > SMART KING: All UPS > VANGUARD: All UPS > ULTIMATE: All UPS > ONLINE: All UPSOk, if all these UPSes are described by the above protocol, I only need to be sure that at least one of them works correctly with the "megatec" driver(*). (*) I especially need to know if the shutdown process works correcly, as megatec uses the "shutdown and restore" command even for the cases where the UPS should be permanently shut down (in all models supported up to now the "SxxR00" command is equivalent to "Sxx" in the above document). -- Carlos Rodrigues