drew einhorn
2009-Mar-11 17:37 UTC
[CentOS] LSI Logic MegaRAID 8480 Storage controller policies?
Life is much better now that I'm using -h instead of the manual. I have a new question about policies Direct and DisDskCache makes sense Cached and EnDiskCache makes sense not so sure about Direct and EnDskCache Cached and DisDsk Cache Do they make sense? -- Drew Einhorn
Joseph L. Casale
2009-Mar-11 18:55 UTC
[CentOS] LSI Logic MegaRAID 8480 Storage controller policies?
>Life is much better now that I'm using -h instead of the manual. > >I have a new question about policies > >Direct and DisDskCache makes sense >Cached and EnDiskCache makes sense > >not so sure about > >Direct and EnDskCache >Cached and DisDsk Cache > >Do they make sense?I believe Cached|Direct refers to adapter based caching of the logical (virtual) disk whereas EnDskCache|DisDskCache refers to physical disk cache. The adapter can hold data in the event of a powerloss with a BBU but I can't see how the disc could. jlc
Apparently Analagous Threads
- LSI Logic MegaRAID 8480 Storage controller
- reboot of nut managment node resets Tripplite SMX1000LCD
- RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05)
- c6, LSI megaraid drive failure notification
- SuperMicro with LSI MegaRaid with Centos 6.0