Chris Bagnall
2006-Feb-13 14:21 UTC
[Asterisk-Users] iLBC issue: An ilbc frame that isn't a multiple of 50 bytes long from RTP (38)
Hello all, I've started implementing iLBC on some of the ATAs we have floating around clients' homes, but I'm coming against this error message with most of them: codec_ilbc.c: Huh? An ilbc frame that isn't a multiple of 50 bytes long from RTP (38)? The ATAs in question are various Grandstream models - the HT486 being the predominant one. Looking at the list archives, it's been an issue for others in the past, but there doesn't appear to have been a satisfactory solution I could find. I understand it's an issue with payload types, so as recommended in the posts I've read, DTMF is set to payload type 101 and iLBC to 97. I've also tried 99 as per another post I read. Is anyone reliably running Grandstream ATAs with iLBC? If so, what settings did you use for the payload types? Any other suggestions for solving the problem would be gratefully appreciated. Thanks in advance. Regards, Chris -- C.M. Bagnall, Director, Minotaur I.T. Limited This email is made from 100% recycled electrons
Bob Goddard
2006-Feb-14 04:43 UTC
[Asterisk-Users] iLBC issue: An ilbc frame that isn't a multiple of 50 bytes long from RTP (38)
On Monday 13 Feb 2006 21:21, Chris Bagnall wrote:> Hello all, > > I've started implementing iLBC on some of the ATAs we have floating around > clients' homes, but I'm coming against this error message with most of > them: codec_ilbc.c: Huh? An ilbc frame that isn't a multiple of 50 bytes > long from RTP (38)?[...] Chris, don't know if it will help, but make sure that the iLBC frame size is set to 30ms. B -- http://www.mailtrap.org.uk/