Hi, I hope some can help me out, as I have a problem with the vpb driver in *, and I am hoping someone has hit these issues and can offer some advice. First off, I'm connected to a British Telecom SystemX exhange with the local Tel Co. I can ring out fine, but when the callee on POTS answers, the vpb driver detects a loop drop and immediantly disconnects the call. I have currently set LoopDropDetect = 0 in vpb.conf but then when the remote user terminates the call, and I hang up on my Polycom Sip phone, SystemX calls me back straight away. So I really need Loop Drop Detection working so I can end the call properly, but if LoopDropDetect = 1 the call is terminated as soon as the callee answers. Does anyone know of a work around? I came in this morning to find 1800ish missed calls where SystemX had tried calling back because vpb was keeping the line alive. Second issue is that I can call out on port 1-4 and dial back into * from POTS. The incoming call is recieved and answered by the autoatendant on port 1-1. However if I go to another phone and try to initiate another call, I cannot grab another line (1-3 would be next outgoing on the card). I either get a dead line or just the SystemX dial tone, as though the vpb has opened the line, but not sent the DTMF. If anyone can help I would really appriciate it, Kind Regards, Ian Bonham _________________________________________________________________ Express yourself instantly with MSN Messenger! Download today it's FREE! http://messenger.msn.click-url.com/go/onm00200471ave/direct/01/