Tmima Pliroforikis Perifereiakis Enotitas Pierias
2012-Jun-26 06:01 UTC
[Nut-upsuser] NUT MGE Pulsar Ellipse Premium 800: Changed NUT rw variables?
Hello all, I've got an MGE Pulsar Ellipse Premium 800 powering a couple of FreeBSD systems. Driver used is mge-shut, I don't know what the new mge-shut driver offers, but I follow the "if it works, don't fix it" dogma here. :) I also had a nut server installed on the master, with the /usr/local/etc/rc.d/nut script slightly modified to include a couple of upsrw commands in order to power off ups and also to delay ups start-up: gw[/root]# diff nut.mod nut.orig 34d33 < stop_precmd="nut_prestop" 41,50d39 < nut_prestop() { < if (test -f /etc/killpower) then < rm /etc/killpower < sleep 5 < echo "Ordering UPS to delay-shutdown." < ${nut_prefix}/bin/upsrw -s ups.delay.shutdown=80 -u user -p pass mailfw at localhost < ${nut_prefix}/bin/upsrw -s ups.delay.start=15 -u user -p pass mailfw at localhost < fi < } < This script worked just fine for a number of years. Yesterday, while looking the syslogs after a power failure, I saw that during the nut-initiated shutdown procedure (notice the "Ordering UPS to delay-shutdown" message) errors were logged, most likely due to these two commands: Jun 24 19:28:37 mail upslog[858]: Signal 15: exiting Jun 24 19:28:37 mail kernel: . Jun 24 19:28:37 mail kernel: Stopping nut_upslog. Jun 24 19:28:42 mail kernel: Ordering UPS to delay-shutdown. Jun 24 19:28:42 mail kernel: Unexpected response from upsd: ERR VAR-NOT-SUPPORTED Jun 24 19:28:42 mail kernel: Unexpected response from upsd: ERR VAR-NOT-SUPPORTED So my question is, have these commands changed? From the output of upsrw below, most likely ups.delay.shutdown and ups.delay.start have been replaced by ups.timer.shutdown and ups.timer.start. Is that correct, are these phrasal changes only? For the record: # upsc mailfw battery.charge: 100 battery.charge.low: 30 battery.runtime: 456 device.mfr: MGE UPS SYSTEMS device.model: ellipse premium 800 device.serial: unknown device.type: ups driver.name: mge-shut driver.parameter.pollinterval: 2 driver.parameter.port: /dev/cuau0 driver.version: 2.6.1 driver.version.internal: 0.69 outlet.1.autoswitch.charge.low: 0 outlet.1.desc: PowerShare Outlet 1 outlet.1.id: 2 outlet.1.switch: 1 outlet.1.switchable: 1 outlet.desc: Main Outlet outlet.id: 1 outlet.switchable: 0 output.voltage: 230 ups.load: 40 ups.mfr: MGE UPS SYSTEMS ups.model: ellipse premium 800 ups.power.nominal: 800 ups.serial: unknown ups.status: OL CHRG ups.timer.shutdown: -1 ups.timer.start: -1 # upscmd -l mailfw Instant commands supported on UPS [mailfw]: load.off - Turn off the load immediately load.on - Turn on the load immediately shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off test.battery.start - Start a battery test test.battery.stop - Stop the battery test ]# upsrw mailfw [outlet.1.autoswitch.charge.low] Remaining battery level to power off this outlet (percent) Type: STRING Value: 0 [outlet.1.desc] Outlet description Type: STRING Value: PowerShare Outlet 1 [outlet.1.switch] Outlet switch control Type: STRING Value: 1 [outlet.desc] Outlet description Type: STRING Value: Main Outlet [ups.timer.shutdown] Time before the load will be shutdown (seconds) Type: STRING Value: -1 [ups.timer.start] Time before the load will be started (seconds) Type: STRING Value: -1 BR, M.-
Arnaud Quette
2012-Jun-27 16:21 UTC
[Nut-upsuser] NUT MGE Pulsar Ellipse Premium 800: Changed NUT rw variables?
2012/6/26 Tmima Pliroforikis Perifereiakis Enotitas Pierias < pliroforiki at pieria.pkm.gov.gr>> Hello all, >Hello,> I've got an MGE Pulsar Ellipse Premium 800 powering a couple of FreeBSD > systems. Driver used is mge-shut, I don't know what the new mge-shut driver > offers, but I follow the "if it works, don't fix it" dogma here. :) >well, as of 2.6.4, switching to newmge-shut is highly recommend. It will solve your issue with ups.{delay,timer}.{start,shutdown}. most notably, mge-shut is not evolving anymore, while newmge-shut does, through sharing a common HID core with usbhid-ups. SHUT means Serial HID UPS Transfer, and is about the same as USB, but on a serial link. I also had a nut server installed on the master, with the> /usr/local/etc/rc.d/nut script slightly modified to include a couple of > upsrw commands in order to power off ups and also to delay ups start-up: > > gw[/root]# diff nut.mod nut.orig > 34d33 > < stop_precmd="nut_prestop" > 41,50d39 > < nut_prestop() { > < if (test -f /etc/killpower) then > < rm /etc/killpower > < sleep 5 > < echo "Ordering UPS to delay-shutdown." > < ${nut_prefix}/bin/upsrw -s ups.delay.shutdown=80 -u user -p pass > mailfw at localhost > < ${nut_prefix}/bin/upsrw -s ups.delay.start=15 -u user -p pass > mailfw at localhost > < fi > < } > < > > This script worked just fine for a number of years. Yesterday, while > looking the syslogs after a power failure, I saw that during the > nut-initiated shutdown procedure (notice the "Ordering UPS to > delay-shutdown" message) errors were logged, most likely due to these two > commands: > > Jun 24 19:28:37 mail upslog[858]: Signal 15: exiting > Jun 24 19:28:37 mail kernel: . > Jun 24 19:28:37 mail kernel: Stopping nut_upslog. > Jun 24 19:28:42 mail kernel: Ordering UPS to delay-shutdown. > Jun 24 19:28:42 mail kernel: Unexpected response from upsd: ERR > VAR-NOT-SUPPORTED > Jun 24 19:28:42 mail kernel: Unexpected response from upsd: ERR > VAR-NOT-SUPPORTED > > So my question is, have these commands changed? From the output of upsrw > below, most likely ups.delay.shutdown and ups.delay.start have been > replaced by ups.timer.shutdown and ups.timer.start. Is that correct, are > these phrasal changes only? >these have indeed been changed (mea culpa) in mge-shut, but not in newmge-shut. note that the latter will replace the former in the next release... cheers, Arnaud -- Linux / Unix / Opensource Engineering Expert - Eaton - http://opensource.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120627/324c0212/attachment.html>
Seemingly Similar Threads
- Random but persistent USB disconnect/reconnect with MGE Pulsar Ellipse Premium
- MGE Pulsar Ellipse 800 offearly or box shutdown late
- Outlet switching on the MGE Pulsar 1500 using usbhid-ups on FreeBSD
- Resetting replace battery status on Pulsar 1500
- MGE Pulsar Ellipse 800 off early or box shutdown late