McCann, Brian
2012-Feb-22 15:31 UTC
[Nut-upsdev] [HCL] CyberPower OR700 supported by usbhid-ups
CyberPower OR700LCDRM1U (http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/rackmount-lcd/OR700LCDRM1U.html) upsc output: battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 6000 battery.runtime.low: 300 battery.type: PbAcid battery.voltage: 14.5 battery.voltage.nominal: 12 device.mfr: CPS device.model: UPS OR700 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.version: 2.6.1 driver.version.data: CyberPower HID 0.3 driver.version.internal: 0.35 input.transfer.high: 140 input.transfer.low: 90 input.voltage: 119.0 input.voltage.nominal: 120 output.voltage: 119.0 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.load: 0 ups.mfr: CPS ups.model: UPS OR700 ups.productid: 0601 ups.realpower.nominal: 400 ups.status: OL ups.test.result: Done and passed ups.timer.shutdown: -60 ups.timer.start: -60 ups.vendorid: 0764 System shutdown cleanly. Was tested on FreeBSD 8.1
Arnaud Quette
2012-Feb-27 11:48 UTC
[Nut-upsdev] [HCL] CyberPower OR700 supported by usbhid-ups
Hi Brian, 2012/2/22 McCann, Brian <bmccann at andmore.com>:> CyberPower OR700LCDRM1U (http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/rackmount-lcd/OR700LCDRM1U.html) > upsc output: > > battery.charge: 100 > battery.charge.low: 10 > battery.charge.warning: 20 > battery.mfr.date: CPS > battery.runtime: 6000 > battery.runtime.low: 300 > battery.type: PbAcid > battery.voltage: 14.5 > battery.voltage.nominal: 12 > device.mfr: CPS > device.model: UPS OR700 > device.type: ups > driver.name: usbhid-ups > driver.parameter.pollfreq: 30 > driver.parameter.pollinterval: 2 > driver.parameter.port: auto > driver.version: 2.6.1 > driver.version.data: CyberPower HID 0.3 > driver.version.internal: 0.35 > input.transfer.high: 140 > input.transfer.low: 90 > input.voltage: 119.0 > input.voltage.nominal: 120 > output.voltage: 119.0 > ups.beeper.status: enabled > ups.delay.shutdown: 20 > ups.delay.start: 30 > ups.load: 0 > ups.mfr: CPS > ups.model: UPS OR700 > ups.productid: 0601 > ups.realpower.nominal: 400 > ups.status: OL > ups.test.result: Done and passed > ups.timer.shutdown: -60 > ups.timer.start: -60 > ups.vendorid: 0764 > > System shutdown cleanly. ?Was tested on FreeBSD 8.1thanks for your report. I've just committed (r3468) an entry in the HCL. for the sake of completion, could you also send us upsrw and upscmd outputs? cheers, Arnaud -- Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/ Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.free.fr/