Hello, I've got a running system in which logs are full of messages such as: [Jun 10 07:24:14] NOTICE[2414] chan_dahdi.c: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 2 The strange thing is those messages are coming from a single span. My setup is : Asterisk 1.6.1.18 Junghanns OctoBRI with wcb4xxp driver libpri 1.4.10.2 dahdi 2.3.0 3 BRI lines in PtMP mode What does this "PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 2" roughly mean ? Why could it happen on a single port and not on the others ? Regards -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.digium.com/pipermail/asterisk-users/attachments/20100611/f2c77e21/attachment.htm
Gareth Blades
2010-Jun-11 10:54 UTC
[asterisk-users] HDLC Bad FCS (8) on Primary D-channel
Basically it means that one of the messages it received on the PRI D channel failed the checksum. I take it that in your span command you have 'crc4' or similar specified as an option for all of your spans? If thats the case its probably a faulty port on the card, cable, or a card in the local telephone exchange, Olivier wrote:> Hello, > > I've got a running system in which logs are full of messages such as: > [Jun 10 07:24:14] NOTICE[2414] chan_dahdi.c: PRI got event: HDLC Bad FCS > (8) on Primary D-channel of span 2 > > The strange thing is those messages are coming from a single span. > > My setup is : > > Asterisk 1.6.1.18 > Junghanns OctoBRI > with wcb4xxp driver > libpri 1.4.10.2 > dahdi 2.3.0 > 3 BRI lines in PtMP mode > > > What does this "PRI got event: HDLC Bad FCS (8) on Primary D-channel of > span 2" roughly mean ? > Why could it happen on a single port and not on the others ? > > Regards >
Seemingly Similar Threads
- Suddenly "HDLC Bad FCS (8)" errors on ISDN-PRI, changed nothing
- HDLC bad FCS
- Asterisk 10/1.6.1 and Dahdi/Libpri compatilities in BRI /PtmP
- CAS signalling on span 2 conflicts with HDLC with FCS check on channel 20
- PRI got event: HDLC Bad FCS (8) on Primary D-channel of span