similar to: UPS heartbeat on battery

Displaying 20 results from an estimated 5000 matches similar to: "UPS heartbeat on battery"

2025 Mar 29
1
UPS heartbeat on battery
The problem with computers - they do what you tell them to, not what you might want them to. Here your heartbeat.dev literally tells the emulation driver to set ups.status=OL, wait 300s, set it to OB, wait 300s, repeat. So NUT reporting that the heartbeat UPS became on-battery 5 minutes after start means these pieces are doing their job correctly and talking to each other well. Jim On Sat, Mar
2013 Sep 13
3
SSL with startssl.com certificates
I'm using Dovecot 2.2.5. I'm setting up and new IMAPS server for personal use (i.e. only me). I have success with self-signed certificates but not with others (e.g. StartSSL.com) With StartSSL certs: I've been able to connect and test commands via: openssl s_client -connect imaps.unixathome.org:993 Can you configure your iPhone or Macbook to access the above? Authentication
2023 Jun 11
1
Upssched 100% CPU after updating Debian 12
Hi, I have been running nut successfully for a long time with my Debian 11 server. I upgraded my server to Debian 12 today, which upgraded nut also from 2.7.4-13 to 2.8.0-7. I noticed that after upgrade there was a upssched process running and taking 100% cpu time. I checked if there were any changes to configuration file formats with nut upgrade and only differences I noticed were a terminology
2023 Jun 16
1
Dummy-ups cycles between online and onbatt every 5 minutes. (Nut 2.8.0)
Now that upsstats.cgi works, I've noticed that dummy-ups changes state every 5 minutes between OL and OB (probably when the 300 second timer expires). The UPS state stays online. Also "online" and "onbatt" are broadcast to the console probably via WALL. (The state changes don't seem to be form the ups as upsshed-cmd doesn't run). Upssched-cmd does run when the UPS
2024 Dec 22
1
clearing the 'Replace Battery' on Eaton 5PX
On Sun, Dec 22, 2024, at 2:53 PM, Dan Langille via Nut-upsuser wrote: > I thought I could clear the Eaton 5PX battery message. I've failed. > > The following is based on > https://haefelfinger.ch/posts/2020/2020-09-23-reset-battery-alert-eaton-5p-ups/ > > I shutdown the UPS. I disconnected it from power. I disconnected both > the main battery and the external battery
2017 Apr 02
0
Heartbeat validation of NUT integrity
This note describes a heartbeat technique for validating the integrity of a NUT installation. Introduction ------------ A NUT configuration may run for months with little or no output to a system administrator to assure that the combined processes are running correctly. The technique described in this note verifies that the ups driver, upsd, upsmon, upssched and upssched-cmd components are
2017 Apr 03
2
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On 04/03/2017 07:03 PM, Gene Heskett wrote: > > But it does that because you have tried to get 12 years out of a gell > cell battery that is doing really really well if you get 4 years out of > it. I am not saying you should do that _now_, without first replacing > that thoroughly boiled dry battery, but as something you should set it > up to do once you have a serviceable
2024 Mar 29
2
Heartbeat timer failure 15 minutes after startup
On Fri, 29 Mar 2024, Dan Grostick wrote: > It is consistently happening 14-15 minutes after starting. Please see attached > upssched-cmd and upssched.conf. I don't have a upssched.cmd. The binary > upssched is used. After the heartbeat failure, is upsd still running? Does the command "upsc -L" report the UPS's? If you use systemd, what does the command
2017 Apr 04
2
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On Tue, 4 Apr 2017, Arnaud Quette wrote: > Hi Jon, Stuart and the list > > 2017-04-04 1:09 GMT+02:00 Stuart Gathman <stuart at gathman.org>: > Which NOTIFYCMD is run when there is an ALARM? > Have you specified that in your upsmon.conf? > > And that is the question of the hour.? How do you specify that?? Note > that this is not the REPLBATT
2010 May 05
1
heartbeat package in extras trouble with 5.4
I just recently upgraded a box from i386 5.3 -> 5.4. The box has heartbeat packages installed from "extras:" heartbeat-pils-2.1.3-3.el5.centos heartbeat-stonith-2.1.3-3.el5.centos heartbeat-devel-2.1.3-3.el5.centos heartbeat-2.1.3-3.el5.centos The heartbeat daemon no longer starts.. the init script reports a success, as well as the logs: May 4 22:33:10 fc-fmcln02 heartbeat: [9344]:
2007 Jun 28
1
Heartbeat for Centos 5- Can't build RPMS or install prebuilt RPMS
I am stuck. This is X86_64 platform. In the extras repos, there is the SRPMS for heartbeat along with the RPMS for it. I have downloaded both. But I can't build the RPMS from the SRPM as it fails compiling something in BUILD/heartbeat-2.0.8/lib/crm/pengine Additionally, I can't install the RPMS: rpm -Uvh heartbeat-2.0.8-3.el5.centos.i386.rpm heartbeat-2.0.8-3.el5.centos.x86_64.rpm
2009 Nov 13
1
Cannot set heartbeat dead threshold
Hi I have: SLES 10 SP2 (2.6.16.60-0.21-smp) ocfs2-tools-1.4.0-0.3 ocfs2console-1.4.0-0.3 and I can't change "heartbeat dead threshold" value. Content of /etc/sysconfig/o2cb: # O2CB_ENABLED: 'true' means to load the driver on boot. O2CB_ENABLED=true # O2CB_BOOTCLUSTER: If not empty, the name of a cluster to start. O2CB_BOOTCLUSTER=ocfs2 # O2CB_HEARTBEAT_THRESHOLD:
2009 Mar 30
3
Two sets of Heartbeat HTTPD clusters on same subnet
Hi all, I am new to Hearbeat so please be kind :) I also posted this on Linux-HA lists with no responses so I posted it here. I have successfully configure two machines to use heartbeat to cluster httpd. The two nodes are called etk-1 and etk-2. I am trying to configure another two machines to act as a separate cluster (on the same IP subnet). These two nodes are called radu-1 and radu-2.
2024 Dec 22
1
clearing the 'Replace Battery' on Eaton 5PX
I thought I could clear the Eaton 5PX battery message. I've failed. The following is based on https://haefelfinger.ch/posts/2020/2020-09-23-reset-battery-alert-eaton-5p-ups/ I shutdown the UPS. I disconnected it from power. I disconnected both the main battery and the external battery pack. I pressed the power on button several times, until the clicking stopped.... I waited 10 minutes.
2010 Dec 12
1
heartbeat configuration for lb
hello list! I am attempting to setup haproxy using a shared up I am trying to setup using the heartbeat package that I currently have installed: [root at VIRTCENT01:~]#rpm -qa | grep heartbeat | grep -v -e stonith -e pils heartbeat-2.1.4-11.el5 heartbeat-2.1.4-11.el5 I have /etc/ha/.d authkeys setup this way: # auth 2 #1 crc 2 sha1 {SHA}secret I have /etc/ha.d/resources setup like this:
2012 Apr 21
1
R CMD check -- non S3 method warning
I'm trying to R CMD check a package, and I'm getting the 'checking S3 generic/method consistency' warning. I have written a function 'gamma.dist' which is _not_ an S3 method, but happens to collide with the 'gamma' function from the R::base namespace. Is there a way of telling CMD check that the name is intentional and is not meant to be an S3 method? My function
2012 May 23
1
openldap mmr + heartbeat hot standby
Hi List, I've setup 2 openldap servers in n-way multimaster replication mode in a test environment, both run centos 6.2, this works well but now i'm trying to make these 2 servers failover using heartbeat. i've got no experience with heartbeat (or setting up clusters in general) however from what i understand heartbeat starts/stops the service if the server has the virtual IP
2024 Nov 21
1
tdb_expand overflow detected
On Wed, Nov 20, 2024, at 6:31 PM, Douglas Bagnall wrote: > On 20/11/24 11:55, Dan Langille wrote: > >> Hope that helps. > > Not much unfortunately. > > Running this: > > net cache list > > will tell you what the cache thinks it contains. If it is filled with > real things, it could indicate where they're coming from. If it fails or > shows a cache
2020 Sep 11
1
UPS recommendation for NUT and power-on-delay support
On Fri, Sep 11, 2020, at 4:05 PM, Bartosz wrote: > Dear All, > > Could you please recommend me a UPS with 100% support of the ondelay parameter and NUT compatibility? > > 850 or 1000 VA > > I have the EATON 5E850iUSBDIN UPS and it does not support this parameter so I would like to buy another UPS that for sure will support it. > > Thank you, > Bart Can you tell
2007 Jul 30
2
incredible heartbeat 2.X depencies
# activating extras repo # issuing "yum install heartbeat" # got : (...tons of depedencies resolution...) ttmkfdir-3.0.9-20.el4.i38 100% |=========================| 6.6 kB 00:00 ---> Package ttmkfdir.i386 0:3.0.9-20.el4 set to be updated --> Running transaction check Dependencies Resolved =============================================================================