similar to: Powercom BNT USB fix needs testing

Displaying 20 results from an estimated 8000 matches similar to: "Powercom BNT USB fix needs testing"

2017 Apr 28
3
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent four last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2017 Apr 26
0
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent three last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2006 Apr 21
1
Powercom BNT-1200AP
Hello I have UPS Powercom Black Knight Pro 1200 (BNT-1200AP) I try to use nut, but powercom driver not understand my model Ok, i try to use type KIN1500AP and it's work But powercom driver can't set UPS's shutdown delay time Also i have powercom's original program (upsmon), and this program can do it What can i do for help to add this function to nut's powercom driver? For
2017 Apr 30
0
Powercom BNT-2000AP(USB)
On April 28, 2017 9:11:59 AM GMT+03:00, "????????? ?????????" <vtk-alexb at mail.ru> wrote: >Hello all! > >Some days ago we received new UPS?Powercom BNT-2000AP with USB >interface to replace an old staff and I've spent four last days trying >to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. > ># dmesg|grep -i powercom >ugen0.3:
2013 May 01
1
Powercom BNT-1500AP serial config
Hey all, Finally got around to hooking up my Powercom BNT-1500AP to nut. It's the old serial interface. Connects okay and gets most information, but a couple of data are way off. Any config recommendations or upgrade recommended? I've played with config a little, but no hits yet. Details: NUT version 2.4.3 ups.conf: [ups] driver = powercom port = /dev/ttyS0
2006 Jul 08
0
Powercom BNT-600AP and NUT (powercom driver)
Hello, I'm new there. I bought an UPS Powercom BNT-600AP. It's compatible in NUT with driver powercom and protocol type KIN1500AP. But I have a simple problem: the 'upsc' shows wrong values in battery.charge (maybe in other rows also /ups.load, voltages?/) - if battery is 100% charged it shows only 92.6% or 93.0%. I thing I have wrong values in driver parameters: batteryPercentage,
2005 Jul 06
0
Powercom BNT-1500AP
Hey all, Does anybody know there is a full working setup for the PowerCom BNT-1500AP. I got some stuff working with the Powercom driver and the type set to "KIN1500AP". But it seems that there is still missing usablity. I was wondering if anybody found any better configs? ---- excerpt of ups.conf [AVR1500] driver = powercom port = /dev/ttyS0 desc =
2011 Jan 13
0
[NUT]updated powercom driver for powercom BNT-500AP
Hi, 2010/12/27 ??? <pointbre at naver.com> > First of all, thanks for your effort to NUT Project, > I'm developing remote monitoring solution for many devices based on linux > server. > In field test, we reached the power shutdown problem which may cause the > crack of linux file system. > I search the solution and find NUT project and i'm very glad that NUT >
2010 Feb 04
0
Powercom BNT-800AP
While fundamentally working, I'm having a few issues with the driver... The default voltage quads (for every model) are way off... Showing ~95v when it should be ~117V. I've changed the 4th/final coefficient to +5.0, but haven't tested extensively (with fluctuating voltages). The input/output voltage appears to be swapped _most of the time_. When doing a battery test, or when
2011 Oct 04
2
PowerCOM BNT-800AP (0d9f:0004)
Hello. I've been trying to got it work but haven't luck. I'm using NUT 2.6.0-1 under Windows XP with libusb driver installed (USB\VID_0D9F&PID_0004&REV_0001). I had tryed all options with such config: *PWCOM] driver = usbhid-ups port = auto vendorid = 0d9f desc = "Powercom BNT-800AP" type=BNT* * *Here is output from CMD:*
2009 Jul 27
1
Powercom BNT-1000CS
Hello. I have recently purchased a Powercom BNT-1000CS(Black Knight CS). I am new to NUT(and am not a programmer), but I have noticed that this model does not work with NUT. I am willing to provide details about this UPS for anyone who would like to add support for it(i dont know how to get much info though, so you'll have to tell me how). For starters, this is what happens when I do
2013 Apr 28
0
PowerCOM BNT-1000AP HID instant commands patch
Hello, Got PowerCOM BNT-1000AP, usb id 0d9f:00a6, firmware FW4.A6 nut 2.4.3 on debian stable shows only two instant commands: beeper.toggle - Toggle the UPS beeper -- not working test.battery.start.quick - Start a quick battery test -- works ok. No load and shutdown commands. Trying svn trunk version, with the same results. Debug output shows the problem: 0.035558
2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
Hello all. Try this driver (for nut 2.2.0). See attach. - Trust, KP625AP, Egys models stay as it was - add Powercom's Black Knight Pro model support ( BNT-400/500/600/800/801/1000/1200/1500/2000AP 220-240V ) - add Powercom's King Pro model support ( KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V) - add Powercom's Imperial model support ( IMP-xxxAP,
2013 Nov 27
0
several problems with Powercom BNT-500AP
Hello. It's been a while since I started this topic. I've finally tested it on Linux desktop PC. Nut version 2.6.4-2.3 Basically the behavior is the same as on raspberry pi. It reports "battery needs to be replaced" regularly and I got "on battery" message 114107.780504 Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Input, ReportID: 0x0a, Offset: 2, Size: 1,
2012 Nov 13
1
PowerCom BNT-600AP on ubuntu 12.04.1 AMD64
Hello people, I use a BNT-600AP from PowerCom, and on driver loading (nut service start) the UPS goes off so I cannot use nut as service as the computer goes off with the UPS. When the computer is not using the UPS, but still connected, I see that the UPS goes off for a very short time, does battery check and goes on again. I don't know how to deal with this issue as I cannot use my UPS
2006 Dec 22
1
Powercom BNT-1200AP driver
Hello. What about driver for my UPS? I have changed the powercom driver for myself, but I have made it not absolutely correctly. However, somehow this driver works. Now i have protocol spec for powercom BNT series and attach it to this email. It can be interesting to authors? -- ? ?????????, ??????? ??????? mailto:alex@reutman.ru JID: alex@reutman.ru ICQ: 5052225 -------------- next part
2011 Nov 13
1
Installing Powercom BNT-2000AP on CentOS 5.6
Hi Guys, Am a Linux newbie and need some help setting up this UPS with NUT on Cent OS 5.6. So basically I have the following packages installed with yum: libusb-devel-0.1.12-5.1.x86_64 libusb-devel-0.1.12-5.1.i386 libusb-0.1.12-5.1.x86_64 libusb-0.1.12-5.1.i386 nut-2.2.2-1.el5.x86_64 When I run service ups start I get the following: Starting UPS driver controller:
2024 Feb 20
1
NUT supports new VID/PID
Hello Jim, That?s a great help for me. You?re a so kind person ~ Our engineer download the branches f17d9f5 as below and repackage it for test. After testing, The Beta NUT works well with ST VID "0x0483", PID "0xA430. Please tell me how to speed up for merging this to formal version. May I have your predict schedule if possible? Thanks.
2024 Feb 15
1
NUT supports new VID/PID
Hello, and thanks for the clarifications. As described, the change does not seem to be too complex on the NUT project's side, the PR posted below took about an hour with some research and this write-up, so I'm not sure I can put a price tag on it :) A donation at https://opencollective.com/networkupstools or https://github.com/sponsors/networkupstools would be welcome though, more so a
2013 Jun 08
2
several problems with Powercom BNT-500AP
Thanks for the support. Here's list of when transition to battery with return to utility power within a few seconds occurred in last few days: Wednesday 1:41 11:48 11:54 12:59 13:42 14:42 18:13 18:14 Thursday 5:23 Friday 5:12 7:39 7:43 Saturday 7:34 Here's list of when messages that battery needs replacement occurred: Wednesday 20:34 Thursday 9:07 23:09 Friday 18:25 Saturday 7:32 19:47