Displaying 20 results from an estimated 4000 matches similar to: "There is no voltage information"
2024 Mar 25
0
There is no voltage information
Hello all,
I think I've found the "regression" in Belkin/Liebert USB HID support
which worked for NUT v2.7.4 and reports zero voltages in 2.8.0 -- it was
actually caused by a bug fix: practically the only functional difference
per `git diff v2.7.4..v2.8.0 drivers/belkin-hid.c` is a change from `abs()`
to `fabs()` in order-of-magnitude comparisons like `if( abs(value - 1e-7) <
2024 Mar 25
0
There is no voltage information
Hello all,
I think I've found the "regression" in Belkin/Liebert USB HID support
which worked for NUT v2.7.4 and reports zero voltages in 2.8.0 -- it was
actually caused by a bug fix: practically the only functional difference
per `git diff v2.7.4..v2.8.0 drivers/belkin-hid.c` is a change from `abs()`
to `fabs()` in order-of-magnitude comparisons like `if( abs(value - 1e-7) <
2011 Sep 24
4
LiebertPSP
Apologies for resurrecting an old thread and likely poor formatting - I wasn't subscribed to the list at the time and have copied it out of the archives (http://lists.alioth.debian.org/pipermail/nut-upsuser/2010-July/006104.html).
I've been unable to locate any further progress on this UPS (Liebert 10af:0001) - a thread from 2009
2011 Feb 03
3
Status OB (on battery) when polling a Liebert PSA
Hi all,
This is my first experience with NUT.
I'm trying to test a Liebert PSA 1500 UPS, connected via USB to a single PC.
I have followed the instruction in the "Configuration" section of the online
user manual.
Everything seems to be fine, except that, when I run "upsc
liebert at localhostups.status", it retuns "OB", even if the UPS is
currently online.
Here
2023 Jul 18
0
Liebert PSA 1500 (500, 1000, 650, ...)
Hello
The page https://networkupstools.org/ddl/Liebert/PSA_1500.html don't
contain all information about UPS series PSA.
First, the variable "*device.serial*" is dummy, it is always empty , and
"*ups.serial*" also always empty.
Second, configuration file for the all UPS "PSA" contain these lines:
[PSA]
??? driver = "usbhid-ups"
?? ?port =
2024 Dec 21
1
Liebert Vertiv PSA5
Today I installed NUT on a RPi via the Home Assistant add-on (HA running on HAssOS), to manage a Liebert Vertiv PSA5. I used the latest version of everything.
At first I got these messages in the log:
Bus 001 Device 005: ID 10af:0002 Liebert Corp. PowerSure PST UPS
?
[13:17:32] INFO: Starting the UPS drivers...
This Liebert device (10af:0002) is not (or perhaps not yet) supported
by usbhid-ups.
2024 Sep 22
1
[HCL] Liebert GXT4-1500RT120 supported by usbhid-ups
Liebert GXT4-1500RT120
upsc output:
battery.charge: 100
battery.charge.low: 30
battery.charge.warning: 40
battery.type: PbAcbattery.voltage: 54
battery.voltage.nominal: 48
device.mfr: Emerson Network Power
device.model: Liebert GXT4
device.serial: 1710600384AFBA3
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.flag.ignorelb: enableddriver.name: usbhid-ups
2013 Aug 20
0
Liebert GXT3 ID 10af:0000 Not working
[please keep the list CC'd.]
On Aug 20, 2013, at 12:50 AM, Korviakov Andrey wrote:
> Yes, it's my mistake: UPS used USB cable for communication, but i think that it's simple usb-com cable because nut work with liebert driver on ttyS0 port.
If that is the case, I doubt that usbhid-ups will be able to retrieve any additional information.
> In ups.conf i tried:
>
>
2011 Apr 05
1
NUT upgrade to 2.6.0 in Gentoo with Liebert UPS
I have a 64 bit Gentoo, with a Liebert UPS. The last NUT working version
was sys-power/nut-2.4.1-r1 (I also tried sys-power/nut-2.4.3-r2 but
downgraded, don't remember the reason).
Anyway with the upgrade to sys-power/nut-2.6.0 I started to see this
error message when I try to start upsdrv:
[root at aemaeth:/etc/nut]$ /etc/init.d/upsdrv start
* Starting UPS drivers ...
Network UPS Tools -
2009 Nov 10
1
[PATCH] Add support for Liebert PowerSure PSA to liebert-hid.c
This patch adds support for the following ups to liebert-hid.c:
$ lsusb | grep Liebert
Bus 007 Device 005: ID 10af:0001 Liebert Corp. PowerSure PSA UPS
Using this patch, I'm able to obtain information about the ups via
upsc:
$ upsc upsname
battery.charge: 100
battery.runtime: 1012
battery.type: PbAc
battery.voltage: 1172
battery.voltage.nominal: 12
driver.name: usbhid-ups
2020 Apr 10
1
alsa-plugins
Hi apols as not really speex dev but really struggling to find this info that sure you will know in an instant.
I am trying to compile alsa-plugins so I get the speexdsp as well as the rate conversion and just don’t know how.
pi at raspberrypi:~/alsa-plugins-1.2.2 $ arecord -D mic
ALSA lib dlmisc.c:287:(snd1_dlobj_cache_get) Cannot open shared library
2017 Jun 03
0
Fwd: Emerson Liebert GXT4
On Jun 2, 2017, at 8:28 AM, zefanjas <nut at zefanjas.de> wrote:
> I couldn't get the GXT4 working with usbhid-ups driver. So I need some
> advise to continue to get this device working. The GXT3 seems to be
> working ok with NUT (http://networkupstools.org/ddl/Liebert/GXT3.html).
>
> Here is my ups.conf
>
> [ups]
> driver = usbhid-ups
> port =
2017 Jun 02
2
Fwd: Emerson Liebert GXT4
Hello,
we have a Emerson Liebert GXT4, that we like to connect to our servers
to shut them down if there is a power failure (which happens quite often
in our area).
I couldn't get the GXT4 working with usbhid-ups driver. So I need some
advise to continue to get this device working. The GXT3 seems to be
working ok with NUT (http://networkupstools.org/ddl/Liebert/GXT3.html).
Here is my
2005 Aug 30
0
Liebert PowerSure PSA 500
[FAQ on USB-connected UPSes]
> Remember: this is brand new *experimental* software and is probably
> very broken. Do us a favor and report successes or failures to
> the mailing lists.
No problem ... :
UPS: Liebert PowerSure PSA 500
NUT: Version 2.0.2
Kernel: 2.6.11.5, with CONFIG_USB_HID, CONFIG_USB_HIDINPUT, and
CONFIG_USB_HIDDEV compiled in (statically)
2013 Aug 19
3
Liebert GXT3 ID 10af:0000 Not working
Hello.
I have Liebert GXT3 UPS connected to CentOS Linux with kernel 2.6.32-131.0.15.el6.x86_64 and nut version 2.6.5-2.
lsusb: Bus 002 Device 003: ID 10af:0000 Liebert Corp. UPS
And this UPS detected only with this section in ups.conf:
[liebert]
driver = liebert
port = /dev/ttyS0
but only this variables available:
device.mfr: Liebert
device.model: MultiLink
device.type: ups
2023 Apr 08
1
Vertiv Liebert
Hello,
I was able to get the Vertiv/Liebert UPS (Vertiv Liebert PSA5 1500VA 900W -
PSA5-1500MT120) to start working with NUT and "usbhid" driver, but would
appreciate help to get it to work properly.
Here's the output from the "upsc" command for a Cyberpower UPS I have:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
2013 Aug 20
0
Liebert GXT3 ID 10af:0000 Not working
On Aug 19, 2013, at 12:58 PM, Korviakov Andrey wrote:
> I have Liebert GXT3 UPS connected to CentOS Linux with kernel 2.6.32-131.0.15.el6.x86_64 and nut version 2.6.5-2.
> lsusb: Bus 002 Device 003: ID 10af:0000 Liebert Corp. UPS
>
> And this UPS detected only with this section in ups.conf:
>
> [liebert]
> driver = liebert
> port = /dev/ttyS0
I am confused.
2011 May 30
2
UPS Liebert GXT3 config
Hi all,
I?ve a UPS Liebert GXT3 500-3000VA with USB port.
I?ve install NUT version 2.2.2 from repository packages for Debian Lenny.
Linux kernel 2.6.26
I?ve try to use usbhid-ups driver in ups.conf
[liebert]
driver=usbhid-ups
port=/dev/usb/hiddev0
Debian get the usb:
# lsusb -v
Bus 001 Device 002: ID 10af:0008 Liebert Corp. PowerSure Interactive UPS
Device Descriptor:
bLength
2014 Oct 01
3
Return on experience with an Emerson/Liebert GXT3
Hi.
I would like to share with you my experience on trying to use nut with a Liebert GXT3 on a Debian wheezy with nut-server 2.6.4.
Please find my observations below.
(1) I've installed the packaged version of nut-server
# aptitude install nut-server
(2) I did some tuning for my configuration
#??cat << EOF >> /etc/nut/ups.conf
user=nut
[liebert]
??????? driver=usbhid-ups
2023 Apr 09
1
Vertiv Liebert
Bruce Pleat via Nut-upsuser <nut-upsuser at alioth-lists.debian.net>
writes:
> Here's the (far less lengthy) output for the Vertiv Liebert:
>
> device.mfr: Vertiv Co
> device.model: Liebert PSA5
> device.serial: 22223106602D04C
> device.type: ups
> driver.name: usbhid-ups
> driver.parameter.pollfreq: 30
> driver.parameter.pollinterval: 2
>