Displaying 20 results from an estimated 6000 matches similar to: "[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups"
2017 May 14
2
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
[updated]
OpenBSD 6.1/amd64
NUT 2.7.4p0 (from OpenBSD package)
Results of upsc:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2902
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 26.9
battery.voltage.nominal: 24
device.mfr: CPS
device.model: CP1500AVRLCDa
device.serial: CTHGN200xxxx
device.type: ups
driver.name:
2017 May 21
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
Mike,
Thanks for the info. I have enough to add an entry to the DDL, but I have a few more questions inline.
On May 14, 2017, at 1:21 PM, Mike wrote:
>
> [updated]
>
> OpenBSD 6.1/amd64
> NUT 2.7.4p0 (from OpenBSD package)
>
>
> Results of upsc:
>
> battery.charge: 100
> battery.charge.low: 10
> battery.charge.warning: 20
> battery.mfr.date: CPS
Let
2017 May 31
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On May 22, 2017, at 11:13 AM, Mike <the.lists at mgm51.com> wrote:
>
> On 5/21/2017 10:39 AM, Charles Lepple wrote:
>>
>> Let me know if you're interested in figuring out if the battery.mfr.date value is stored somewhere else.
>
> Of course. The UPS is in production (ie., powering the servers in my
> house), so it may be a few days before I can ~play~.
2017 Jun 05
2
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On 6/4/2017 4:46 PM, Charles Lepple wrote:
[snip]
>> 4) when I went down to 95 volts, the "AVR" kicked in to boost the
>> voltage without going to battery. This was indicated by a "click" from
>> the UPS and an indication on the UPS display.
>
> In non-explore mode, does the driver report the AVR status? (No need to set things back up if you have
2017 May 22
3
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On 5/21/2017 10:39 AM, Charles Lepple wrote:
> Mike,
>
> Thanks for the info. I have enough to add an entry to the DDL, but I have a few more questions inline.
>
> On May 14, 2017, at 1:21 PM, Mike wrote:
>>
>> [updated]
>>
>> OpenBSD 6.1/amd64
>> NUT 2.7.4p0 (from OpenBSD package)
>>
>>
>> Results of upsc:
>>
>>
2017 Jun 05
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On Jun 5, 2017, at 11:21 AM, Mike <the.lists at mgm51.com> wrote:
>
> Result of the command, where "n" is incremented in a loop:
>
> # usbconfig -u 1 -a 2 dump_string n
> STRING_0x00 = 0x04, 0x03, 0x09, 0x04
> STRING_0x01 = <CP1500AVRLCDa>
> STRING_0x02 = <CTHGN200xxxx>
> STRING_0x03 = <CPS>
> STRING_0x04 = <PbAcid>
>
2017 Jun 04
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On Jun 3, 2017, at 2:21 PM, Mike <the.lists at mgm51.com> wrote:
>
> On 5/30/2017 10:47 PM, Charles Lepple wrote:
>> On May 22, 2017, at 11:13 AM, Mike <the.lists at mgm51.com> wrote:
>>>
>>> On 5/21/2017 10:39 AM, Charles Lepple wrote:
> [snip]
>
>> Even though the CPS sub-driver has been written already, I would like to take a look at the
2018 Sep 26
0
[HCL] Cyber Power Systems AVRG750U supported by usbhid-ups
Cyber Power Systems AVRG750U
https://www.cyberpowersystems.com/product/ups/avrg750u/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 15360
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: AVRG750U
device.serial: <REDACTED>
device.type: ups
2017 Jun 03
2
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On 5/30/2017 10:47 PM, Charles Lepple wrote:
> On May 22, 2017, at 11:13 AM, Mike <the.lists at mgm51.com> wrote:
>>
>> On 5/21/2017 10:39 AM, Charles Lepple wrote:
[snip]
> Even though the CPS sub-driver has been written already, I would like to take a look at the raw "explore" mode output:
>
>
2016 Dec 08
2
[HCL] Cyber Power Systems EC750G supported by usbhid-ups
I didn't want to sign up for the nut-devs list or create a git account
just to provide this information, so I hope posting this info here is OK...
I just bought a Cyber Power Systems EC750G UPS for use as a spare. Here
are some info for it:
=========================
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime:
2018 Sep 26
1
[HCL] Cyber Power Systems CP600LCD supported by usbhid-ups
Cyber Power Systems CP600LCD
https://www.cyberpowersystems.com/product/ups/cp600lcd/
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 2220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS CP600
device.type: ups
driver.name: usbhid-ups
2013 Nov 22
0
[HCL] CyberPower LE825G supported by Cyber Power Systems ups 2 685AVR USB (usbhid-ups) driver
CyberPower Battery Backup with Surge Protection, model LE825G
Appears to function properly with the driver listed on the HCL for the
Cyber Power Systems ups 2 685AVR USB (usbhid-ups).
Tested with shutdown mode "UPS Goes On Battery" with a 5 second timer
and the system successfully shutdown as expected.
upsc output:
upsc ups
battery.charge: 100
battery.charge.low: 10
2017 Sep 13
0
[HCL] Cyber Power UPS LX1500GU supported by driver usbhid-ups
Cyber Power UPS Model LX1500GU
*upsc output:*
root at freenas:~ # upsc ups at localhost
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 5670
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 24.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: LX1500GU
device.serial: QAKGP2000252
device.type: ups
driver.name:
2016 Dec 09
4
[HCL] Cyber Power Systems EC750G supported by usbhid-ups
On 12/8/2016 10:37 PM, Charles Lepple wrote:
> On Dec 8, 2016, at 1:34 PM, Mike wrote:
>>
>> I didn't want to sign up for the nut-devs list or create a git account
>> just to provide this information, so I hope posting this info here is OK...
>
> Not a problem. (Both lists go into the same mailbox on my end.) The important part is the "HCL" subject so I
2017 Mar 02
0
[HCL] Cyber Power Systems EC750G supported by usbhid-ups [UPS.Output.DelayBeforeShutdown]
On Dec 9, 2016, at 11:14 AM, Mike <the.lists at mgm51.com> wrote:
>
> On 12/8/2016 10:37 PM, Charles Lepple wrote:
>> On Dec 8, 2016, at 1:34 PM, Mike wrote:
>>> The result of the command
>>>
>>> upscmd -u user -p password myups load.off.delay 300
>>>
>>> is an immediate power-off, no delay.
>>
>> Hmm. Certainly
2019 Mar 06
0
HCL Cyberpower CPS-850AVRLCD supported by usbhid
Cyberpower CPS850avrlcd
https://www.cyberpowersystems.com/product/ups/cp850avrlcd/
shutdown sequence: UNTESTED
upsc output:
_____
sudo upsc cp-ups
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1230
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS
2015 Feb 06
0
[HCL] <CyberPower> <Value 1500ELCD-RU> supported by <usbhid-ups>
CyberPower Value 1500ELCD-RU
root at ubuntu:/home/oper# upsc myups at localhost
battery.charge: 87
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 5220
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 16.5
battery.voltage.nominal: 24
device.mfr: CPS
device.model: Value1500E
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq:
2017 Sep 28
1
[HCL] CyberPower EC350G supported by usbhid-ups
[shutdown sequence]
I have tested and verified the shutdown sequence works.
[manufacturor]
https://www.cyberpowersystems.com/product/ups/ec350g/
mbeisser at nas:~$ upsc ups
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1575
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 9.3
2016 Dec 09
0
[HCL] Cyber Power Systems EC750G supported by usbhid-ups
On Dec 8, 2016, at 1:34 PM, Mike wrote:
>
> I didn't want to sign up for the nut-devs list or create a git account
> just to provide this information, so I hope posting this info here is OK...
Not a problem. (Both lists go into the same mailbox on my end.) The important part is the "HCL" subject so I can find it later.
For anyone else who runs across this: you don't
2012 Feb 22
1
[HCL] CyberPower OR700 supported by usbhid-ups
CyberPower OR700LCDRM1U (http://www.cyberpowersystems.com/products/ups-systems/smart-app-ups/rackmount-lcd/OR700LCDRM1U.html)
upsc output:
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 6000
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 14.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UPS OR700