2018 Sep 03
0
Adding drivers to NUT?
[apparently the list didn't get the message, probably because it
exceeds the 40kb threshold, so here it is in all its glory with my
reply]
On Mon, 3 Sep 2018 at 14:32, Gabriele TAORMINA
<gabriele.taormina at legrand.com> wrote:
>
> Dear Daniele,
>
> > "I fixed a few issues, and pushed your changes (amended) to this
> > temporary branch:
2018 Sep 01
0
Adding drivers to NUT?
> sorry for the delay, I forgot to put the automatic response (I was on holiday), here's a description of what we made and the drivers we used to start from:
No problem for the delay...
I fixed a few issues, and pushed your changes (amended) to this
temporary branch: https://github.com/zykh/nut/tree/issue-441+legrand
Let me know if I misunderstood anything...
> - usbhid-ups --> we
2018 Aug 28
1
Fwd: Forward of moderated message
[forwarded without attachments, for real this time]
> Begin forwarded message:
> 
> From: Gabriele TAORMINA <gabriele.taormina at legrand.com <mailto:gabriele.taormina at legrand.com>>
> Subject: Re: [Nut-upsdev] Adding drivers to NUT?
> Date: August 27, 2018 at 6:03:55 AM EDT
> To: Daniele Pezzini <hyouko at gmail.com <mailto:hyouko at gmail.com>>
>
2018 Jul 26
5
Adding drivers to NUT?
Dear Daniele,
nice to meet you, I'm a collegue of Gabriele.
The problem with "blazer_usb" driver ("blazer_ser" works correctly) is related to the following commands:
- "F" and "I": when the KRAULER subdriver check these UPS answers it uses wrong constants to check the lenght of the received packets, so these commands are considered as "not
2020 Feb 11
1
NOTIFYCMD not running
Hi, I'm setting up NUT on a raspberry pi 4, following the guide here:
https://melgrubb.com/2016/12/11/rphs-v2-ups/
OS version: Raspian Buster
NUT version: 2.7.4.8
Installed via: apt package install
Device: Legrand Keor Multiplug connected via USB
The problem I am experiencing is that *NOTIFYCMD* never runs.  I can
connect to the device via *upsc*, and I receive WALL messages when I
connect
2020 Feb 11
1
NOTIFYCMD not running
>I just went through the same issue. Take a look at my thread.
>Double check that upsmon.conf:NOTIFYCMD /sbin/upssched is not still
commented.
Thanks for the response, can you link to it?  I'm not finding it in the
search.   I'm not using /sbin/upssched, I have NOTIFYCMD set up as:
NOTIFYCMD /home/pi/Documents/scripts/ups-log.py
and it's not commented out.
On Tue, Feb 11, 2020
2020 Feb 11
1
NOTIFYCMD not running
I just went through the same issue. Take a look at my thread.
Double check that upsmon.conf:NOTIFYCMD /sbin/upssched is not still
commented.
On Tue, Feb 11, 2020 at 7:00 AM <nut-upsuser-request at alioth-lists.debian.net>
wrote:
> Send Nut-upsuser mailing list submissions to
>         nut-upsuser at alioth-lists.debian.net
>
> To subscribe or unsubscribe via the World Wide
2020 Feb 11
1
NOTIFYCMD not running
>  When you run that command, does "some text" appear in the system log?
When I run Documents/scripts/ups-log.py manually I do see the expected text
echo'ed to the command line.  It actually appends to a Google Sheet, not
the internal log files.
When I would expect to see it triggered by NOTIFYCMD, I don't see any text
printed and nothing shows up at the google sheets.  If
2007 Jan 28
2
sweex 1000VA LB OB issue
Hello folks,
I have a question regarding a sweex product. Its bundled with UPSmart v 
2.12.
I installed nut accordingly to the user manual included in the software. 
A quick check of data/drivers.list revealed to me i should use the:
"Sweex"         "500/1000"      "contact closure - shipped with 
UPSmart"        "genericups upstype=7" driver
this driver
2020 Jun 11
0
Legrand UPS drivers
Good morning,
my name is Stefano Pongiluppi and I'm a Legrand marketing manager, specialized in UPS management systems.
About two years ago, my ex colleague Gabriele Taormina, that was in touch with Daniele Pezzini, sent to you the drivers for Legrand UPS (a copy of them are in attachment), but I see that these drivers are not yet included in the Master branch of the NUT project.
Could you
2018 Jul 04
2
Adding drivers to NUT?
Dear Admin,
I'm working for Legrand UPS and i would like to know the correct procedure to send you some drivers source files to be added in the NUT software, this to extend support also to our UPSs.
Thanks in advance, waiting for a response!
Best Regards,
Gabriele Taormina
UPS Strategic Business Unit
Field Application Engineer
Phone:     +39 0522/207046
Fax:           +39 0522/207005
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL.
According to the drivers list, I should be using genericups with 
upstype set to 7, but when I try that and when I run upsc I get:
driver.name: genericups
driver.parameter.LB: 04
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ups
driver.parameter.upstype: 7
driver.version: 2.2.2
driver.version.internal: 1.34
ups.mfr: CyberPower
2008 Jul 25
3
CyberPower 550SL reports LB and OB when on line power
I am using nut 2.2.2 and I have a CyberPower CP550SL.
According to the drivers list, I should be using genericups with 
upstype set to 7, but when I try that and when I run upsc I get:
driver.name: genericups
driver.parameter.LB: 04
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ups
driver.parameter.upstype: 7
driver.version: 2.2.2
driver.version.internal: 1.34
ups.mfr: CyberPower
2010 Nov 07
2
mean on a plot
Hi, i need to draw a plot with means of values, reading a table from
datafile.
Example of datafile:
Days	Weight
0	178.00
0	250.00
0	242.00
0	239.00
0	223.00
0	188.00
0	237.00
0	212.00
0	273.00
0	191.00
0	173.00
0	233.00
0	227.00
0	253.00
0	232.00
4	177.00
4	249.00
4	241.00
4	238.00
4	222.00
4	188.00
4	236.00
4	211.00
4	272.00
4	190.00
4	172.00
4	232.00
4	226.00
4	252.00
4	231.00
if i use
2018 Jul 31
0
Adding drivers to NUT?
Dear Daniele,
I have some news regarding the Driver: I applied the patch you sent me (https://github.com/zykh/nut/tree/issue-441) and it works correctly (obviously in Level 5 of Debug I see "missing CR...etc..").
As for now there are 2 modification I'd like to suggest you:
- For Online Type UPSs the Megatec protocol describes that the battery voltage is provided in the form of V
2018 Jul 11
2
Adding drivers to NUT?
Dear Daniele,
thanks a lot for your support, i have some things that are not so clear for me:
- I can send you the whole sources for our UPSs, do you need only Headers and C files or also other files (i suppose Driver list)?
- Seen that we had some problems with the Blazer driver (the battery voltage calculation were not correct for our UPSs) we copied it and modified a bit while changing the
2006 Jul 11
2
notifycmd problem
hello,
  i've got a problem with the notifycmd
here is a part of my upsmon.conf :
NOTIFYCMD /usr/local/ups/bin/nut_notify
NOTIFYMSG ONLINE "UPS %s is getting line power"
NOTIFYMSG ONBATT "UPS %s is on battery"
NOTIFYMSG REPLBATT "The UPS %s battery is bad and needs to be replaced"
NOTIFYMSG LOWBATT "UPS %s is being shutdown by the master"
NOTIFYMSG FSD
2018 Jul 24
2
Adding drivers to NUT?
Dear Daniele,
i understand perfectly, i'd like to explain you why we choosed to clone the blazer_usb driver:
some of our devices uses Voltronic Q1 protocol and we tried the Krauler Subdriver (it was the one with the right "commands", Q1, F, etc.), but the issues were 2:
- first: the Krauler Subdriver expects a different number of bytes in answer because in debug i see "Short
2014 Mar 31
0
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card [UPDATE]
Hi!
Have a similar issue with one of our customers having HP R12000/3 UPS 
with AF430A card. Upsmon shows the UPS as Online, on Battery and Battery 
discharging at the same time:
[root at smrsrvslv06 lib64]# upsc hpups at localhost
ambient.temperature: 19.0
ambient.temperature.high: 0.00
ambient.temperature.low: 0.00
battery.charge: 94.00
battery.current: 0.00
battery.runtime: 4620.00
2017 Oct 26
0
Monitoring Legrand Niky S
Hello,
I would like to monitor my UPS Legrand Niky S from a Raspberry Pi3 but I have not found it in the compatibility list.
Has anyone been able to monitor an UPS Legrand using NUT?
Your help would be greatly appreciated.
Thanks,