similar to: Problem connecting to APC Smart UPS SC1000 on Windows

Displaying 20 results from an estimated 100 matches similar to: "Problem connecting to APC Smart UPS SC1000 on Windows"

2018 Nov 29
0
Problem to connect to APC SC1500
Hello, I am not able to get NUT working with a APC SC1500. The ups has only a serial port and came with a 940-0272a serial to usb cable. The cable has a fake Prolific chip in it, so only works by downgrading the driver to version 3.2. I tested a 940-0024C cable without success as well. The ups works with powerchute and apcupsd with the 940-0272a cable. Have not tested it with the other one. OS:
2013 May 11
1
blazer_ser problem on windows NUT 2.6.5-3780M
Hi, I have a bunch of UPSs, most connected to pcs with Linux working 100% with NUT. The only one I have a problem with, is connected to Windows 7 64bit, and I used the straight MSI installed from the website named NUT-Installer-2.6.5-4.msi Took me a while to find a way to get it to work, but it is ugly for now. Just starting up the service results in a NUT not working at all, and I tracked it
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
Dear Ladies and Gentlemen, I have several old, yet functioning APC Smart-UPS (Model 600LS, Part AP600I, Firmware 6JI, no EEPROM, from 1991). They are not supported by Powerchute any more. I run NUT 2.6.5-4 on Windows XP SP3. I use COM1 port with cable 940-0024C. The connection fails with APC Smart protocol driver 3.0 (2.6.3-3534:3540M), APC command table version 3.0 or higher - it works with APC
2016 Jul 20
0
port for powercom
Ok, so I previously thought I had to use usbhid-ups but when I eventually got it going this is what I got:- This Powercom device (0d9f/0002) is not supported by usbhid-ups. Please use the 'powercom' driver instead. So I switched to the powercom driver, but I have tried a whole bunch of likely suspects for the port setting, none of which have worked Tried so far:- com1 with these
2012 May 10
3
battery.charge and other fixes needed for X-Power Tigra 1kVA
Hello all, been 5 years since I posted on this list, glad to be back :) I have a number of X-power Tigra 1kVA online UPS units. From some knowledgeable folks working for the local distributor, I learnt that from inside this looked like a Best 610 ups unit. Before, I had this UPS hooked via serial to my Windows 2003 server. For monitoring, some winpilot/upspilot software was also provided.
2013 Apr 02
3
blazer driver: Possible bugs with battery packs
Hello all, long time away from this list, glad to be around again! I have this Powercom Vanguard VGN VGD-20K31. Some details of this model: * 3-phase input, single phase output * Model has 240V / 12V9AH x 20 x 2SET, plus another set of 20 batteries. All in all, 3 sets * Serial connection to Windows 2k3 server with UPSMon Now I was strongly considering replacing the bundled no-good upsmoon
2009 Jun 25
1
Runaway apcsmart process
On several occasions I have seen the apcsmart process runaway using 100% CPU while filling my syslog partition by logging the following syslog entries at an incredible rate. I have seen up to 21,800 log entries PER SECOND of the following nature: --[snip]-- Jun 25 10:06:38 servername apcsmart[4012]: Communications with UPS lost: Communications with UPS lost - check cabling Jun 25 10:06:38
2007 May 31
0
Proposed addition to apcsmart driver
Hi Alex, since I have no knowledge of the apcsmart driver, nor much time currently, I've forwarded your msg to the NUT development list. I hope somebody can take over your call. btw, please subscribe to the list for further discussions... 2007/5/28, Alex Brodsky <abrodsky at acs.uwinnipeg.ca>: > Hi, > > My name is Alex Brodsky, I am a faculty member at University of >
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph > On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote: > > I definitely need more info! > > please reply to ALL: > > > - what is the exact model and date of manufacturing? > > SmartUPS 300I NET. I have the serial number (GS9809283199) but no date. > it seems to be a recent model. > - are you sure this unit is ok? > >
2011 Feb 15
2
[Bug 535583] Excessive logging by apcsmart program
2011/2/15 Lupe Christoph > On Monday, 2011-02-14 at 21:54:20 -0000, Arnaud Quette wrote: > > I definitely need more info! > > please reply to ALL: > > > - what is the exact model and date of manufacturing? > > SmartUPS 300I NET. I have the serial number (GS9809283199) but no date. > it seems to be a recent model. > - are you sure this unit is ok? > >
2006 Jun 19
2
Fw: Backups 300VA (BK-300C) Drivers
[BackUPS] driver = apcsmart port = /dev/ttyS0 desc "Back-UPS BK-300 @ Cap a l'orignal" > ----- Original Message ----- > From: "Charles Lepple" <clepple@gmail.com> > To: "NUT-MList" <nut-upsdev@lists.alioth.debian.org> > Sent: Monday, June 19, 2006 2:38 PM > Subject: Re: [Nut-upsdev] Backups 300VA (BK-300C) Drivers >
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
On 2014-01-14 10:12, dstrr wrote: > Hello. > Trouble to communicate with APC SmartUPS via serial port. > UPS connected to the com1 port on windows host. > Communication witch hyperterm works well. > There is a log: > > YSM > ^ASmart-UPS SC1000 > n5S0713T63247 > m03/29/07 > L240.0 > B27.10 > > apcupsd also can communicate with the UPS and works well. >
2000 Mar 06
1
smbd processes won't go away
Running Samba 2.0.6, on Sun SC1000 (4 CPUs) with Solaris 2.6 smbd processes don't seem to terminate although the connections don't show-up with netstat. The client session seems to terminate, and the connection is terminated, but the smbd process seems to hang around waiting. smb.conf specifies "deadtime=5", and in most cases there is no open file associated with the smbd
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
Hello. Trouble to communicate with APC SmartUPS via serial port. UPS connected to the com1 port on windows host. Communication witch hyperterm works well. There is a log: YSM ^ASmart-UPS SC1000 n5S0713T63247 m03/29/07 L240.0 B27.10 apcupsd also can communicate with the UPS and works well. running apcsmart -a ups gives the following: com1: device reports different attributes than what were set
2013 May 07
2
Problems with USB-serial converters -- please advise on code fix
Hello! I've ran into this annoying issue when setting up a new server. I have an APC SmartUPS hooked up on a USB-serial converter on /dev/ttyUSB0. This works nicely, until: hub 3-0:1.0: port 1 disabled by hub (EMI?), re-enabling... pl2303 ttyUSB0: pl2303 converter now disconnected from ttyUSB0 usb 3-1: pl2303 converter now attached to ttyUSB1 apcsmart gets into an infinite loop of this:
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the manufacturer's PowerChute software and smart signaling, so I have decided to try NUT. The smartups driver can't make contact through the serial port. Since this is rack-mounted, it comes with a 940-1524 serial cable. As far as I can tell, this is supposed to work with smart signaling. Here's my ups.conf:
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master
2006 Jun 19
4
Backups 300VA (BK-300C) Drivers
Hi, What driver should i use with APC BK-300C ? Michale Plourde Digicom Technologies
2011 Jan 25
1
[RFC] Updates to ACP smart driver
This patch introduces a handful of new options, I mentioned earlier in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02088.html See the large commit message in the follow-up for the details and rationale. I realize it's a bit larger diff - so if it's required I can split it into few smaller ones. Michal Soltys (1): APC smart driver update and new features.
2011 Feb 07
4
[PATCH/RFC v2 0/3] Updates to ACP smart driver
This is 2nd version of the earlier patch featuring a few new features and fixes to the apcsmart driver, following the remarks in: http://www.mail-archive.com/nut-upsdev at lists.alioth.debian.org/msg02294.html Major changes from v1: - handle battery.charge and battery.runtime checks at main.c level - handle "immutable but writable" conflict gracefully at driver level -