Displaying 20 results from an estimated 200 matches similar to: "[PATCH 0/3] OpenUPS updates"
2012 Nov 20
2
[PATCH][RFC] OpenUPS driver
Hi all,
I attached a driver for MiniBox openUPS device (
http://www.mini-box.com/OpenUPS) and a dump of the hid usages.
I had the possibility to make a few adjustments to the device firmware for
HID usages, and although I haven't managed to produce a good structure
many issues from previous firmware were at least fixed and new information
added.
ATM the driver only shows pertaining
2018 Feb 04
0
[PATCH 3/3] OpenUPS: fix current calculations
Monitoring the input and output currents reported through upsc for an
OpenUPS device suggests that it is an energy creation device - the
power out is greater than the power into the system once the battery
is fully charged.
Analysis and measurement reveals several issues:
1. "UPS.PowerStatus.Output.Current" is scaled for NUTs "output.current"
value, which should be the
2010 Oct 13
1
[LLVMdev] EXC_BAD_ACCESS: invalid MemoryBuffer from ContentCache::getBuffer
I'm using the latest llvm/clang 2.8 releases and am getting
EXC_BAD_ACCESS crashes in ContentCache::getBuffer. This happens when
I'm printing out errors from a compilation run and iterating over
TextDiagnosticBuffer returned errors.
When checking the errors, I construct a FullSourceLoc and do:
int LineNum = SourceLoc.getInstantiationLineNumber();
int ColNum =
2006 Jan 21
2
snmp-ups hacking
Hi all!
I'm wondering if there's anyone doing any hacking on the snmp-ups
driver at the moment.
I've started looking at implementing 3phase-support, and this
uncovered some rather unpleasant stuff in the snmp-ups driver that I
really need to fix in order to get things sane.
Those of you that's allergic to SNMP might want to stop reading now,
this is rather icky ;)
2023 Nov 12
1
What is the arduino sub-driver intended to be used for?
I posted earlier on this list about getting an Arduino Pro Micro using
https://github.com/abratchik/HIDPowerDevice in a simple sketch to monitor a
DIY UPS I have built. With the changes from that thread (I had a PR
merged), I was able to get usbhid-ups to recognize my device and could
setup NUT the rest of the way. My intended configuration is to run NUT on a
Raspberry Pi, have that device be
2023 Nov 12
1
What is the arduino sub-driver intended to be used for?
Well, the intention generally is to use it as a driver, so the more
abilities the merrier (PR would be welcome) :)
Per comments to initial PR that added it,
https://github.com/networkupstools/nut/pull/1044 :
> The idea of introducing this driver is to enable creation and prototyping
of smart UPS based on Arduino, which is inexpensive versatile platform very
much suitable for custom fully
2023 Nov 13
1
What is the arduino sub-driver intended to be used for?
oh! Ok, I'll go look at all the HID objects reported by the sample
code @abratchik has on top-of-tree of his repo and see what makes sense to
add to NUT. PR coming this week.
On Sun, Nov 12, 2023 at 2:38?PM Jim Klimov <jimklimov+nut at gmail.com> wrote:
> Well, the intention generally is to use it as a driver, so the more
> abilities the merrier (PR would be welcome) :)
>
2007 Aug 10
1
[nut-commits] svn commit r1041 - in trunk: . drivers
Arjen de Korte wrote:
>
> Author: adkorte-guest
> Date: Fri Aug 10 20:23:27 2007
> New Revision: 1041
>
> Log:
> * drivers/usbhid.[ch]:
> - Moved the struct & data for ups.status processing to usbhid.c, since this is only used in there. Subdrivers report the status through text messages, they don't set the status bits directly.
> - Rewrote (flattened) the
2016 May 20
1
ups.status don't switch to "OB LB"
Hello,
I have a Legrand Keor T [1] monitored via snmp, everything seems to work fine, upsc output looks good [2] except that I can?t get the low battery state "OB LB? as usual (it works fine with others UPS like APC or Dell). Here is the configuration :
[lgups]
driver = snmp-ups
port = 192.168.99.60
community = public
snmp_version = v2c
mibs = auto
2014 Jan 10
1
Eaton 5PX broken interrupt on usbhid-ups, also pollfreq vs pollinterval?
Linux NUT 2.7.1
Eaton 5PX usbhid-ups
It would appear that interrupts are not actually working on my 5PX using
the usbhid-ups driver. I will be trying the serial mge-shut driver next.
It just seemed like it was working before because of the default
pollinterval of 2 seconds. The status update comes in during the
pollinterval no matter what I have pollfreq set to. And I can set
pollonly and
2013 Jul 17
2
HP R12000/3 UPS reports status as OL DISCHRG OB
Here's the first update of ups.status:
0.102449 getting data: ups.status (.1.3.6.1.4.1.232.165.3.4.5.0)
0.102546 su_ups_get: ups.status .1.3.6.1.4.1.232.165.3.4.5.0
0.102646 nut_snmp_get(.1.3.6.1.4.1.232.165.3.4.5.0)
0.104539 SNMP UPS driver : entering su_status_set()
0.104641 su_find_infoval: found OL (value: 3)
0.104730 => value: 3
0.104823 getting data: ups.status
2017 Oct 11
4
Junda-tech
Hi,
I have an UPS with only the marking D1000 on it and it came with
Junda-Tech's UpsMate.
Its USB id is 3344:0025, which is apparently a microprocessor.
I've could get some of the HID interactions as described on the website,
but there are some outstanding.
Junda-Tech does not respond to any queries.
Does anybody else have the same or a similar UPS with more information?
What is the
2016 Jun 27
2
query "Data stale" from the cmdline
Hello,
is there a way to query from the cmdline if the UPS data is stale?
"upsc" outputs a lot of information, but not if the data is stale.
Example output from a "stale" UPS on the server:
(nut version: nut-2.7.2-3.el7)
# upsc apcsmart
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.mfr.date: 2014/09/01
battery.runtime: 1320
2007 Aug 11
1
apc-hid.c: watts_to_av_conversion
Peter,
Looking through the usbhid-ups subdrivers, I came across the following
function in apc-hid.c, presumably added by you about two years ago (if
not, my apologies):
41 /* returns statically allocated string - must not use it again before
42 done with result! */
43 static char *watts_to_av_conversion_fun(long value) {
44 static char buf[20];
45
46 snprintf(buf,
2013 Jul 16
0
HP R12000/3 UPS reports status as OL DISCHRG OB
Sorry about that!
Chris.
Chris Pratt
Development Infrastructure Manager
T: +44 118 929 4176 | M: +44 7979 854 307 | F: +44 118 929 4001
-----Original Message-----
From: Charles Lepple [mailto:clepple at gmail.com]
Sent: 16 July 2013 00:32
To: Pratt Chris
Subject: Re: [Nut-upsuser] HP R12000/3 UPS reports status as OL DISCHRG OB
On Jul 15, 2013, at 9:35 AM, Pratt Chris wrote:
> Debug output
2024 Mar 14
1
Are all measurements are in seconds?
Hi,
I am studying (in a few months I might go on a TV quiz show :-)
Rodger's excelent guide and wanted to confirm that all measurements in
NUT are in seconds.
For example, the Cyber Power System CP1500 AVR UPS returns that the
**driver.parameter.pollfreq = 30**. This means that I can (maybe
should) adjust the settings within NUT.CONF to match this value.
Setting this value to 2 seconds gains
2005 Aug 13
1
A newhidups question
Gentlemen,
I think this question is mainly for Arnaud again:
When I run my UPS directly with newhidups -D -D -D, with no data changes,
and I then observe the interaction with my UPS (still Back-UPS ES 650
FW:818.w1.D USB FW:w1), I see the updateinfo cycle through 3 different forms:
(1) a (2 bytes) => 06 08 notification that provides one item:
UPS.PowerSummary.APCStatusFlag
Note that
2005 Aug 25
3
Tr : NUT patches
Hi Peter,
I've forwarded your mail to upsdev as it will be of interest for several
people that are working on it. As I'm also on vacation (again) for a
week and 1/2 as of this evening, I don't think I'll have the time for it
before I get back....
I've not yet audited the patches, but these are queued on the
Alioth tracker:
2013 Jul 03
1
bcmxcp: Patch for adding ups.load and battery.voltage.low
On Jul 2, 2013, at 5:16 PM, Kjell Claesson wrote:
>> I hope other people can also test this.
>>
>> Regards
>> Alf Hogemark
>
> Due to some crashes on the disks and lack of time I don't have the git on the
> pc now. But maybe some other can commit this.
I'd like to ask people to specifically try the bcmxcp branch on GitHub - it includes some changes
2013 Jul 15
4
HP R12000/3 UPS reports status as OL DISCHRG OB
Hi.
Back before Christmas Arnaud sent me a patch for the snmp-ups driver for my HP R12000/3 UPS. Unfortunately shortly after I had to take quite a lot of sick leave so wasn't able to progress it, but I'm working on it again now.
I'm at the point where I can start the driver with upsdrvctl and start the daemon with upsd. When I check the UPS status though it shows as OL DISCHRG OB,