sysOID for SMART-UPS 2200 RM XL
Hello. Just wanted to report this sysOID to you. The UPSC output is below. Network UPS Tools - Generic SNMP UPS driver 0.70 (2.7.1) kill: No such process No matching MIB found for sysOID '.1.3.6.1.4.1.318.1.3.2.11'! Please report it to NUT developers, with an 'upsc' output for your device. Going back to the classic MIB detection method. Detected SMART-UPS 2200 RM XL on host
2020 Apr 29
0
[EXTERNAL] SNMP shutdown timing out
Is NUT using the same SNMP v3 user as your SNMP Set or a different one? If it is a different one (e.g. an SNMP v1 or v2c string) does that user / community string have read/write access? tcpdump to listen for packets across UDP 161 is one way to check what is actually being sent. Thank you, David Zomaya Tripp Lite ________________________________ From: Nut-upsuser
2020 Apr 29
2
SNMP shutdown timing out
I'm in the process of trying to get NUT to manage an APC SmartUPS. Monitoring of the UPS is working fine: $ upsc nutdev1 at localhost Init SSL without certificate database ambient.1.humidity.alarm.high: 60.00 ambient.1.humidity.alarm.low: 30.00 ambient.1.temperature.alarm.high: 40.00 ambient.1.temperature.alarm.low: 10.00 battery.charge: 94.00 battery.charge.restart: 0 battery.current: 0.00
2005 Nov 18
1
APC Matrix 5000 UPS
Hello, I can get nut to work with this UPS using the apcsmart driver, but only with limited functionality. It is only reporting the OL/OB status and that's about it. None of the other useful variables such as run time, load etc are reported and initiating battery tests does not work either. Has anyone managed to get nut to report more than these variables with a Matrix type UPS? I see
2009 Jul 09
1
apcsmart and dual environmental sensors
Hi, We have a several AP9612TH environmental cards (they have 2 probe connectors) inserted into our APC UPS devices which monitor temperature and humidity. The apcsmart nut module knows how to query the ambient.temperature and ambient.humidity using the 't' and 'h' commands of the UPS (refer to apcsmart.h). The results of the 't' and 'h' commands are from probe 1.
2009 May 07
1
Findings of dual APC UPS sensor attachments
Hi, We have several APC Smart UPSes (serial port/apcsmart) with the APC Temp/Humidity sensor cards (AP9612TH). The sensor cards have 2 plugs for 2 separate sensors. So far, we have only used one of the sensors in conjunction with the apcsmart module from nut. This has been working great. Example output: [nut at nut]# upsc APC11 ambient.humidity: 037.2 ambient.humidity.alarm.maximum: NO,NO
2008 Sep 19
1
APC SmartUPS 750 (SUA750) missing ambient data with usbhid-ups
I have a SmartUPS 750 (SUA750) which has the temperature and humidity SmartSlot card installed. When NUT 2.2 communicates with this UPS over /dev/ttyS0 using apcsmart, using the APC Smart cable connected to the SUA750 serial port, and this ups.conf: [su700] driver=apcsmart port = /dev/ttyS0 I can see the ambient temperature and humidity data with "upsc su700 at
2017 Jul 07
0
Eaton PW9130 1500VA-T with netxml-ups driver
Hello, I have some questions about netxml-ups driver. My UPS: Eaton PW9130 1500VA-T with Network Management Card. OS: Fedora 24 NUT 2.7.4 (from fedoraproject repo) Driver: netxml-ups. Results of upsc: ambient.humidity.high: 90 ambient.humidity.low: 5 ambient.temperature.high: 40 ambient.temperature.low: 5 battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.runtime: 69012
2008 Sep 26
2
bar and line plot
Hello All: Using the below dataset how can I make a barplot with Date(X) and NumEggs(Y) by Site. Then plot Temp(lineplot) It seems really simple, but I am having a hard time trying to do it by Site. Thanks Date NumEggs Site Temp 1 2008-04-22 0 Massacre Flat (RK424.5) 51.20 2 2008-04-23 0 Massacre Flat (RK424.5) 50.80 3 2008-04-24
2012 Jan 05
1
Re old message CPQPOWER-MIB - nearly there (using snmp-ups with HP AH401A management card)
Hi, This appears to be related to a thread from January 2010: http://lists.alioth.debian.org/pipermail/nut-upsdev/2010-January/004470.html NB: This is on an HP-UX 11.31 box, using a self compiled and packaged version of NUT 2.6.3, and net-snmp v5.7.1. Therefore some of the search paths and things like that may well be wrong because I've done something dumb. I'm also only just getting
2006 Jul 03
2
could i change the ouput style on summary?
Dear friends, summary() doesn't give a good ouput style,e.g.: grass soiltem airtem gheight humidity altitude diluo :38 Min. :15.90 Min. :17.70 Min. : 8.00 Min. : 0.2360 high: 43 huanghuacai:32 1st Qu.:19.32 1st Qu.:22.60 1st Qu.:40.00 1st Qu.: 0.3190 low :119 hucao :46 Median :20.20 Median :25.30 Median :60.00
2007 Feb 09
3
? has mib:::udp[In/Out]Datagrams been superceded by mib:::udpHC[In/Out]Datagrams
Hi, Looking at some udp stuff on snv_57, and I noticed that mib:::udpInDatagrams no longer exists, has this been superceded by mib:::udpHCInDatagrams? From my understanding they represent the same counter, but I''m asking in case this is a bug. I noticed that there is still a reference to udpInDatagrams in the DTrace testsuite. - Fintan
2017 Oct 31
0
Updating snmp-mib.c with new Cyberpower v2.0 MIB
On October 31, 2017 2:32:36 AM GMT+01:00, Ben Kamen <ben at benkamen.net> wrote: >Hey all, > > >?I'm feeling spunky... and want to update nut to handle the new v2.0 >MIB from CyberPower. > >I've looked at the cyberpower v0.1 .c/.h and being new to working on >nut to this level -- anything anyone has to offer on adding code >besides the obvious? >
2017 Nov 02
0
Updating snmp-mib.c with new Cyberpower v2.0 MIB
On November 2, 2017 5:31:42 AM GMT+01:00, Ben Kamen <ben at benkamen.net> wrote: >On 10/31/2017 01:13 AM, Jim Klimov wrote: >> If the new data is in a separate OID tree, it can quite be a new MIB. >Otherwise you can use the UNIQUE flag and set the preferred (e.g. >newer, more precise) source for a value first in the list of same-named >mappings in existing file - if
2017 Nov 02
2
Updating snmp-mib.c with new Cyberpower v2.0 MIB
On 11/02/2017 01:52 AM, Jim Klimov wrote: > > I believe the main reason for a new set of .c/.h files here would be if the new MIB is defined in a separate subtree. The top-level mapping binds the vendor entry OIDs (often "hidden" so one has to know where to poke). It may also be higher in the list of snmp-ups.h, in case the device also serves the older MIB but you'd prefer the
2017 Nov 06
0
Updating snmp-mib.c with new Cyberpower v2.0 MIB
Chugging along... Question for the gang -- CyberPower lists other items in their MIB for controlling PD units and some other things. Does NUT support all that and should I make an effort to get all that in or should we skip for now and get UPS primary ingredients inserted and tested? just wondering, ?-Ben -- Ben Kamen - O.D.T., S.P.
2019 Aug 12
0
limited resolution on DVI and HDMI at the same time
I got 1920x1200 at 59.95Hz via DVI and 3840x2160 at 60.00Hz via HDMI at the same time with the proprietary nvidia driver. I get flickering on the 1920x1200 at 59.95 with the nouveau driver (it doesn't flicker if I lower it to 1920x1080 at 59.96). Any idea why? proprietary: $ xrandr Screen 0: minimum 8 x 8, current 5760 x 2160, maximum 32767 x 32767 DVI-D-0 connected primary 1920x1200+0+0
2017 Oct 31
2
Updating snmp-mib.c with new Cyberpower v2.0 MIB
Hey all, ?I'm feeling spunky... and want to update nut to handle the new v2.0 MIB from CyberPower. I've looked at the cyberpower v0.1 .c/.h and being new to working on nut to this level -- anything anyone has to offer on adding code besides the obvious? like: should the 0.1 and 2.0 coexist somehow? (maybe different files) (also, is there a list of all the parms I can match up from the
2014 Aug 11
0
Meaning of Battery Resting/PW-MIBs
Hi, just testing with a HP R1500 XR (answers as Powerware) with SNMP/Serial Port Card using SNMP I found: 1st: The batt status 1.3.6.1.4.1.534.1.2.5.0 goes away after some time. Isn't visible in a snmpwalk anymore, seems to be a bug in the card. 2nd: The ups turns into "resting" 48h after battery is full. It turns off the fan, the batt voltage lowers a little, it seems, avoiding
2017 Nov 02
2
Updating snmp-mib.c with new Cyberpower v2.0 MIB
On 10/31/2017 01:13 AM, Jim Klimov wrote: > If the new data is in a separate OID tree, it can quite be a new MIB. Otherwise you can use the UNIQUE flag and set the preferred (e.g. newer, more precise) source for a value first in the list of same-named mappings in existing file - if there's a hit on an actual device, it will be used and not iterated onwards. The flag is not yet supported for