2013 Mar 08
0
HowTo use upssched right.
Hi,
I want to test the events off my UPS.
I define
In upsmon.conf:
RUN_AS_USER root
NOTIFYCMD /sbin/upssched
NOTIFYMSG ONLINE "UPS %s on line power"
NOTIFYMSG ONBATT "UPS %s on battery"
NOTIFYMSG LOWBATT "UPS %s battery is low"
# NOTIFYMSG FSD "UPS %s: forced shutdown in progress"
NOTIFYMSG COMMOK "Communications with UPS %s established"
2020 Mar 10
2
Fwd: Windows upssched does not work
Hi,
I have problem with upssched on windows. Upssched is not executed. I
have 2 scripts, 1 for notification in upsmon and second for scheduling
in upssched. Monitoring is working fine, script write to log. I'm
using binary windows installer 2.6.5-6 from NUT.
Here are my configs:
--- nut.conf
MODE=netclient
--- upsmon.conf
MONITOR ups_1000 at 192.168.3.95 1 <user> <password> slave
2017 Oct 31
0
Email Alerts for Multiple UPSs with upssched
There's supposedly another way with a custom upsmon.conf:
NOTIFYMSG type message
upsmon comes with a set of stock messages for various events. You can change them if you like.
NOTIFYMSG ONLINE "UPS %s is getting line power"
NOTIFYMSG ONBATT "Someone pulled the plug on %s"
Note that %s is replaced with the identifier of the UPS in question.
The message must be one
2023 Jun 13
1
Upssched 100% CPU after updating Debian 12
Hi,
I ran the strace command while upssched was 100% CPU hungry. This is what I got:
1686633611.702798 read(7, "", 1) = 0 <0.000004>
1686633611.702816 read(7, "", 1) = 0 <0.000004>
1686633611.702834 pselect6(11, [7 10], NULL, NULL, {tv_sec=1, tv_nsec=0}, NULL) = 1 (in [7], left {tv_sec=0, tv_nsec=999998800}) <0.000006>
1686633611.702862 read(7,
2023 Jun 13
1
Upssched 100% CPU after updating Debian 12
Hi,
I ran the strace command while upssched was 100% CPU hungry. This is what I got:
1686633611.702798 read(7, "", 1) = 0 <0.000004>
1686633611.702816 read(7, "", 1) = 0 <0.000004>
1686633611.702834 pselect6(11, [7 10], NULL, NULL, {tv_sec=1, tv_nsec=0}, NULL) = 1 (in [7], left {tv_sec=0, tv_nsec=999998800}) <0.000006>
1686633611.702862 read(7,
2023 Jun 11
1
Upssched 100% CPU after updating Debian 12
Hi,
I have been running nut successfully for a long time with my Debian 11 server. I upgraded my server to Debian 12 today, which upgraded nut also from 2.7.4-13 to 2.8.0-7. I noticed that after upgrade there was a upssched process running and taking 100% cpu time.
I checked if there were any changes to configuration file formats with nut upgrade and only differences I noticed were a terminology
2018 Sep 20
3
Upssched not getting called from UPSMON
Hi, I cant seem to get my upssched to get called by upsmon. Upsmon -c fsd just shuts down without the message I set or the one in upssched-cmd
/etc/ups/upsmon.conf:
MONITOR ups6 at localhost 1 <user> <pass> master
MONITOR ups8 at localhost 1 <user> <pass> master
SHUTDOWNCMD "/sbin/shutdown -h +0"
NOTIFYCMD /usr/sbin/upssched
NOTIFYMSG
2018 Sep 21
0
Upssched not getting called from UPSMON
Where syslog output ends up is an OS specific question and depends upon the configuration of the system logger in use.
On most systems the logging information will be found in /var/log. On most Linux systems, the default system log is /var/log/messages.
Denny
> On Sep 20, 2018, at 13:30, Ito-Cole, Kaeny (Student) <Kaeny.Ito-Cole.stu at gtri.gatech.edu> wrote:
>
> First
2018 Sep 21
1
Upssched not getting called from UPSMON
Ah yes sorry I forgot to specify I am on CentOS 7 and the newest NUT for that is 2.7.2
On 9/21/18, 9:04 AM, "Denny Page" <denny at cococafe.com> wrote:
Where syslog output ends up is an OS specific question and depends upon the configuration of the system logger in use.
On most systems the logging information will be found in /var/log. On most Linux systems, the
2016 Jun 14
5
Besoin d’aide pour upssched
Bonjour
je n?arrive pas ? configurer convenablement NUT pour qu?il m?adresse
des SMS en cas de coupure de courant.
C?est important pour moi car dans ma maison les coupures sont tr?s fr?quentes.
Voici ma configuration :
******************************************************************
1/ dans /etc/nut/upsmon.conf
MONITOR eaton at localhost 1 admin motdepasse master
MINSUPPLIES 1
SHUTDOWNCMD
2012 Jun 25
1
upssched script doesn't start on event
Dear list,
Can't make upssched notify me on event occured.
OS: Debian, 2.6.26-1-amd64
Nut: 2.4.3-1.1squeeze1
UPS: Ippon Smart Winner 3000 connected via COM
On event ( plug out the cord from UPS ) upsmon detect's status change to
OB and gives WALL and syslog notify, but no script starting. In syslog
no errors and no upssched process occured, just upsmon. There're no
PIPE and LOCK
2006 May 09
4
upssched does not start the script when timer triggers
Hello,
I'm using nut with my MG Ellipse on serial port. No problem since one
year. Two days ago, I wanted to add a phone alert through my asterisk
box when power is down. Since then, upssched doesn't make his job
anymore. here is the "syslog" I get when the power cord is unplugged :
>
> May 9 11:39:34 serveur upsmon[6411]: UPS ellipse@localhost on battery
> May 9
2017 Jun 09
0
Apple Mac slave
On Fri, 9 Jun 2017, Robbie van der Walle wrote:
> # NOTIFYMSG - change messages sent by upsmon when certain events occur
> #
> # You can change the default messages to something else if you like.
> #
> # NOTIFYMSG <notify type> "message"
> #
> # NOTIFYMSG ONLINE "UPS %s on line power"
> # NOTIFYMSG ONBATT "UPS %s on battery"
> #
2015 Oct 27
0
The system doesn't shutdown
On Tue, 27 Oct 2015, George Anchev wrote:
> Yes, that was the power off test. However the upssched-cmd script gave
> absolutely no signs of activity. Even it's logger lines don't show up in
> journalctl. No any permission error messages - nothing. Only the 2
> messages from upsmon - on battery and then on line power.
>
> Here is the nut-report:
>
2015 Jul 15
3
No messages
Charles,
This is how I have the upsmon.conf set up. ?The only time I get a message is if the?NUT Monitor gui is running. ?I open LXterminal, pull the wall plug, and I get no messagesin the terminal.
?MONITOR Asium_p700 at localhost 1 upsmon jsamcr master?MINSUPPLIES 1?SHUTDOWNCMD "/sbin/shutdown -h +0"?NOTIFYCMD /sbin/upssched?POLLFREQ 5?POLLFREQALERT 5?HOSTSYNC 15?DEADTIME
2006 Jul 11
2
notifycmd problem
hello,
i've got a problem with the notifycmd
here is a part of my upsmon.conf :
NOTIFYCMD /usr/local/ups/bin/nut_notify
NOTIFYMSG ONLINE "UPS %s is getting line power"
NOTIFYMSG ONBATT "UPS %s is on battery"
NOTIFYMSG REPLBATT "The UPS %s battery is bad and needs to be replaced"
NOTIFYMSG LOWBATT "UPS %s is being shutdown by the master"
NOTIFYMSG FSD
2010 Jan 09
2
problem with mailing (nut 2.4.1 and a powermust650 -> megatec_usb)
Hello guys
Yesterday i started do configure my Mustek Powermust650 with nut using
the megatec_usb driver. Everything works fine except for the mailing
when something happens. My upsmon looks like this:
MONITOR powermust650 at localhost 1 local controller master
MINSUPPLIES 1
SHUTDOWNCMD "/sbin/shutdown -h +0"
NOTIFYCMD /root/upsmailer
POLLFREQ 10
POLLFREQALERT 5
HOSTSYNC 15
2020 Oct 24
0
[Announcement] Python3 scripts to replace upsmon, upssched, upssched-cmd
UPSmon.py
---------
I have been experimenting with a Python3 re-implementation of upsmon,
upssched and upssched-cmd. This is currently in use on openSUSE and
Debian boxes. It provides a much richer "language" for UPS management.
For example, the key part of the well known "warn on [OB], shutdown on
[LB]" approach is written as
# Warnings when on-battery, wait for low
2012 Jan 28
2
No shutdown on empty battery
Hello,
I set up a FreeBSD 8.2 system with nut 2.6.1 and a Powerware 5115
connected by RS-232. I expected this setup to shut down before running
out of battery power, but I either missed some important configuration
or something else went wrong:
The syslog says:
Jan 9 05:03:42 b1 upsmon[67752]: UPS upsb1 at localhost on battery
Jan 9 05:04:42 b1 upsmon[67752]: UPS upsb1 at localhost on line
2017 Oct 18
2
debian 8 "jessie" nut 2.7.2 slaves not shutting down
MASTER SYSTEM
nut.conf
MODE=netserver
ups.conf
[TOPAPC]
driver = usbhid-ups
port = auto
pollonly
serial = "IS1309002707"
desc = "TOPAPC"
[MIDAPC]
driver = usbhid-ups
port = auto
pollonly
serial = "IS1309001233"
desc = "MIDAPC"
[BOTAPC]
driver = usbhid-ups
port = auto