Socomec ITYS 3000 + Netvision upsmon output
On 02.10.2014 03:42, Charles Lepple wrote: > On Oct 1, 2014, at 5:07 AM, Tarvo.Tiits at automaatika.ee wrote: > >> Why is ups.status empty? > If I understand the commit log for SVN r3590, then that revision was supposed to set the status to OL if the numeric state was 9 for ECO mode. It does not appear to do that: > >
2014 Oct 02
0
Socomec ITYS 3000 + Netvision upsmon output
On Oct 2, 2014, at 1:53 AM, Tarvo Tiits <Tarvo.Tiits at automaatika.ee> wrote: > On 02.10.2014 03:42, Charles Lepple wrote: >> On Oct 1, 2014, at 5:07 AM, Tarvo.Tiits at automaatika.ee wrote: >> >>> Why is ups.status empty? >> If I understand the commit log for SVN r3590, then that revision was supposed to set the status to OL if the numeric state was 9 for
2015 Mar 31
3
Tripplite SNMPwebcard communication lost and established randomly
[please use Reply-All to keep the list CC'd, thanks] On Mar 30, 2015, at 11:04 PM, Jason Gould <jgould at cddiagnostics.com> wrote: > Thanks. I should also mention the freenas server is setup with an lacp lagg. > > I will also mention that even when not setting pollfreq (leave as default) the issue still occurs. > It looks like the default for pollfreq is actually 30 on
2015 Mar 31
0
Tripplite SNMPwebcard communication lost and established randomly
I missed that snmp-ups set pollfreq to 30 by default. I'd hope that it would set deadtime to an appropriate value as well than, no? Is there a way to query what the settings are or what the defaults are? I'm going to set POLLFREQ=30 and DEADTIME = 90 and see if that has any effect. I'll check for the logs. And if that doesn't get my anywhere I'll look at trying to simulate
2019 Jan 27
4
Just an interesting data point
SO, my full load on my core UPS is two Dell R610s, one Sun X4540, one HP DL360p gen8, two six-core Thuban-II workstations plua their monitors, and the network stack and KVM. The APC SU3000RM (3KVA) that blew up last week considered this to be just short of 60% load. The new Cyberpower PR3000 (also 3KVA), wqhich operates at a 90% power factor, considers this same load to be 43% load. I wasn't
2015 May 28
4
upsmon and Chloride UPS
Hi, We have 2 UPS Chloride 80 NET 120 ( a black and white one ) in our datacenter. Could you please tell me if it is possible to use upsmon or other free solution with these two UPS for shuting down servers during electrical lost power before battery crash . Beet regards, Roger -------------- next part -------------- An HTML attachment was scrubbed... URL:
2014 Feb 26
2
Arch Linux and Tripp Lite web snmp card issues.
Sorry, I just now figured out how to get a usable output. -Option one doesn't work at all for me. snmp_build: unknown failuresnmpget: Error building ASN.1 representation (Can't build OID for variable) COUNT = 0 / 0 Creating /usr/share/snmp/mibs/ups-mib.txt-mib.h Creating /usr/share/snmp/mibs/ups-mib.txt-mib.c Done. -Option 2 is attached. I ran the following to get the output. snmpwalk
2004 Jun 19
7
QoS net-snmp ?
Hi I''ve patched net-mrtg http://www.net-snmp.org/ with http://x-ray.prokon.cz/data/snmp/ sucefully Also I''ve copied QOS.TXT to /usr/local/share/snmp/mibs when I make a normal use of snmp, with mrtg in order to monitor all traffic on eth0 and eth1, it works OK. But, how must I do in order to get monitor for a specific class ? If I make a snmpwalk (like README suggest), I get
2004 Aug 20
1
Win2K Clients Getting Password Prompt When Trying To Access Samba Shares
I'm running Samba 3.0.4 with Kerberos 5 v 1.3.4. I'm accessing Win2k shares from the Samba box without a hitch, but whenever I try to open up Samba shares on the Win2K clients, I get a password prompt. If I access the shares via the IP address of the Samba machine, there's no problem. I don't know if this is relevant, but my Win2k PDC is showing the following error on a
2014 Feb 26
0
Arch Linux and Tripp Lite web snmp card issues.
2014-02-26 1:45 GMT+01:00 Jason R Begley <jayray at digitalgoat.com>: > Sorry, I just now figured out how to get a usable output. > -Option one doesn't work at all for me. > > snmp_build: unknown failuresnmpget: Error building ASN.1 representation > (Can't build OID for variable) > COUNT = 0 / 0 > Creating /usr/share/snmp/mibs/ups-mib.txt-mib.h > Creating
2014 Feb 12
3
Tripplite UPS (SU10KRT3/1X) through snmp-ups (nut 2.6.5)
Thanks, now I started getting messages from the list. As you advised, I renamed the mib file NETCARD.mib to Tripplite and ran command ./gen-snmp-subdriver.sh -H 10.200.254.39 -c public -n Tripplite Here is what it says: snmp_build: unknown failuresnmpget: Error building ASN.1 representation (Can't build OID for variable) COUNT = 0 / 0 Creating tripplite-mib.h Creating tripplite-mib.c Done.
2014 Feb 26
0
Arch Linux and Tripp Lite web snmp card issues.
On Feb 25, 2014, at 4:23 PM, Arnaud Quette wrote: > gen-snmp-subdriver.sh simply hasn't done its job, for some reasons. > well, 1 clear is that's it not a completed effort... at all > but, still IIRC, it should have produced at least a bit more Hi Arnaud, I may not have been specific enough in my description. The crash that Jason saw is with the version of snmp-ups that is
2014 Feb 25
3
Arch Linux and Tripp Lite web snmp card issues.
2014-02-25 12:58 GMT+01:00 Charles Lepple <clepple at gmail.com>: > On Feb 24, 2014, at 11:48 PM, Jason R Begley wrote: > > > 0.073855 load_mib2nut: trying classic method with 'delta_ups' mib > > 0.073878 Entering nut_snmp_get_str() > > 0.073899 nut_snmp_get((null)) > > 0.073918 nut_snmp_walk((null)) > > Arnaud, > >
2005 Sep 23
4
Reading SNMP on other machine
I'm trying to use snmpwalk to look at other machines, but I can't get a response. It keeps timing out. It can see itself, though. I haven't had this problem with other machines and I don't know what's different. Suggestions? -------------- next part -------------- An HTML attachment was scrubbed... URL:
2018 Aug 08
2
Query NUT via SNMP on Linux?
I'm wondering if it is possible to use SNMP to query a NUT instance running on a Raspbian Linux host. Please note, I am NOT talking about querying a UPS via SNMP, but rather interrogating NUT *about* the UPS from another SNMP system. Currently, when I do snmpwalk talking to the NUT host, all I see is very limited information (location, hostname, etc.) So I know SNMP is running and
2009 Apr 21
8
One for the Cisco experts...
I have a Cisco 6509 switch that I'm monitoring with SNMP from a CentOS5 machine. SNMP polls are the only access I have to this device, we are not allowed to log on via telnet. How can I find out which port on the switch a particular server is connected to? I was hoping that this is somehow possible using the mac address and the data gathered from snmpwalk/snmpget requests but I'm not
2007 May 26
2
Issues with SNMP
Hello, I'm wondering if anyone else is seeing the same issues I'm seeing here. I have recently upgraded one of my systems from 4.4 to 4.5 and ever since then I cannot get snmp to work. I am monitoring the interface traffic. Please keep in mind the firewall/router I do the same thing without any issues for 4 interfaces and it is still at 4.4 and doesn't have any issues. If I
2015 Mar 31
2
Tripplite SNMPwebcard communication lost and established randomly
On Mar 31, 2015, at 9:07 AM, Jason Gould <jgould at cddiagnostics.com> wrote: > I missed that snmp-ups set pollfreq to 30 by default. I?d hope that it would set deadtime to an appropriate value as well than, no? Is there a way to query what the settings are or what the defaults are? There is a TODO comment in snmp-ups that mentions doing something similar to usbhid-ups: just poll the
2006 Apr 06
2
SNMP EXTENSION
Hi ALL, I am trying to use the SNMP extension of michel http://x-ray.prokon.cz/data/snmp/ i pached the snmpd damon as mentioned in the README but when i run "snmpwalk -c community target enterprises.18756" i get this error "snmpwalk: No securityName specified (Sub-id not found: (top) -> enterprises)" any idea ? Thanks , venkat
2015 Mar 26
2
snmpwalk Mixed Fail
Hi All, I have a C6 (latest patches) physical machine that I use for network and server monitoring, predominantly over SNMP. It is on VLAN80. My network management interfaces on the switches are on VLAN50 with routing between the VLANs. I recently changed the router to a CISCO ASA 5505 (reasonably recent IOS version, certainly post HeartBleed), with the management interface on a higher