similar to: Incorrect Values From usbhid-ups

Displaying 20 results from an estimated 4000 matches similar to: "Incorrect Values From usbhid-ups"

2020 Oct 23
2
Nut-upsuser Digest, Vol 184, Issue 8
Thanks again for your patience. I'm still learning how to deal with systemctl myself (and starting from, I'm sure, a much lower level of understanding), so if I've neglected to restart or start something, please let me know. I made the change to /etc/nut/upsd.conf. I restarted upsdrvctl, which reported back: Network UPS Tools - UPS driver controller 2.7.4 Network UPS Tools - Generic
2016 Dec 03
2
Problem installing NUT on 16.04
This is new install on Ubuntu 16.04, using packages from Synaptic, *Network UPS Tools upsd 2.7.2 I am getting these messages in the terminal: Broadcast message from nut at amethi (somewhere) (Fri Dec 2 12:33:03 2016): UPS CyberUPS1 at localhost is unavailable I am still unclear on where to set when nut shutdowns system. I see nut-client and nut server are automatically starting from SystemD.
2020 Oct 21
1
Can't get CyberPower UPS to work with Raspberry Pi 4
I've searched the listserv archive, to no avail, so I hope I'm not duplicating a previous problem. I am anxious to get this working, so I'm open to uninstalling what I have and starting over. One note which may not be meaningful is that this UPS pre-dates the Raspberry Pi I've got connected to it, and I used to use it with the CyberPower software, which requires logging in with a
2016 May 04
2
New UPS Support: Eaton 5S 1000
Charles, It starts out good, then goes into a Connection timed out loop. If I can provide any information to fix a driver I'll do my best. Here's the output: # /usr/local/ups/bin/usbhid-ups -DD -a eaton Network UPS Tools - Generic HID driver 0.41 (2.7.4) USB communication driver 0.33 0.000000 debug level is '2' 0.002550 upsdrv_initups... 0.288229 Checking device
2012 Jul 18
1
Problem connecting to eaton ups. No matching HID UPS found. Driver failed to start(exit status=1)
Hi! Info OS: TinyCore Linux 4.5.6 NUT version: 2.6.4 NUT innstallation method: source tarball Device name: Eaton Ellipse ups eco 1600 usb din (EL1600USBDIN) /usr/local/ups/etc/ups.conf file: [eaton] driver = usbhid-ups port = auto When I run: root at Dalen:/usr/local/ups/bin/upsdrvctl start eaton I get this error message: Network UPS Tools - UPS driver controller 2.6.4
2016 May 28
2
Powercom INF-800 support
Hello. Not listed as supported, so here is some info, [root at vhost ~]# /usr/sbin/usbhid-ups -DD -a powercom Network UPS Tools - Generic HID driver 0.38 (2.7.2) USB communication driver 0.32 0.000000 debug level is '2' 0.001318 upsdrv_initups... 0.074753 Checking device (0529/0001) (003/002) 0.074835 Failed to open device, skipping. (Permission denied)
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi, This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status. Details of our installation are: OS: Debian 6 NUT version: 2.7.4 Installation method: from source tarball UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in
2013 Aug 07
4
HP R1500 G3 problems
Hi there, OS: (L)ubuntu 12.04 precise LTS Nut: 2.6.3-1ubuntu1.1 Installation Method: Package (apt-get install nut) Hardware: HP R1500 G3 INT Hardware-Specs: http://h18004.www1.hp.com/products/quickspecs/14059_div/14059_div.pdf Problem: I tried to set up nut with our new arrived HP R1500 G3 UPS but there is a failure with the usb connection. After trying "/lib/nut/usbhid-ups -DD -a
2015 Jan 12
2
persistent "low battery" condition
On 10/01/2015 00:45, Charles Lepple wrote: > On Jan 8, 2015, at 11:43 PM, Graham Menhennitt > <graham at menhennitt.com.au <mailto:graham at menhennitt.com.au>> wrote: > >> Hello Nutters, >> >> I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) >> with an APC Back-UPS CS 350 connected via USB. I get persistent >> (every few
2008 Dec 31
2
Unknown product ID for Tripp-Lite UPS (SU1500RTXL2UA)
To all, I attempted to configure the UPS tools for the Tripp-Lite SmartOnline 1500VA 2U rackmount UPS. I followed the instructions from the 'upsdrvctl start' output and posted the diagnostic information below. Is my UPS using an unknown product ID as reported? From the mailing list archive, I have found another posting for the same UPS with device model '09AE/4003', whereas
2019 Dec 08
3
Tripp Lite SMART1500LCD repeatedly disconnecting and reconnecting
My UPS is connected to a Raspberry Pi by USB. After a few hours of working, the service fails. Looking at kernel messages I noticed that the device is repeatedly disconnecting and reconnecting. I have tried using a different USB port and using a brand new USB cable. I have not had success by changing config parameters like pollfreq/pollinterval/etc. What is causing the UPS to keep disconnecting?
2020 Sep 03
2
UPS reboots with APC UPS
Hello, I have been using NUT for a short period of time and have some questions regarding the UPS reboot signal that I can't figure out. Have tried some googling and reading the DOCs but I am struggling to understand how some variables / things are supposed to work, so would appreciate any help with any of the following questions. I am running NUT on standalone mode on a linux machine
2010 Dec 16
6
CyberPower Value 2200E-GP
I've just set up a CyberPower Value 2200E-GP on a system running Lucid AMD64, with the current NUT package via apt-get, and it seems to be working fine for me with the usbhid-ups driver, so I guess it can go in the HCL? I'm using the system to host several virtual servers under KVM, and to make things simple I set it up to hibernate rather than shutdown, that way all the guest OS
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
Thanks for the reply. However these two FAQ are unfortunately not describing the situation. - The first issue is that NUT switches off the UPS upon reboot on low battery (not that it dies because of low battery) - The second issue is that the UPS does not recognise being online again (not that the PC does not restart) Sent from my iPhone > On 11 Jun 2019, at 02:03, Charles Lepple <clepple
2017 Aug 21
5
TrippLite SMART1500LCD no delay before ups shutdown.
Hello, I am hoping someone can point me in the right direction. I am setting up a new UPS, most things seem to be working except the UPS turns off immediately during a test shutdown using///"//upsmon -c fsd".//No delay before the UPS turns itself off leaving no time for the server to shutdown properly. I have attempted to set the delay higher using "upsrw -s
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
On Jun 10, 2019, at 2:32 PM, Marc Finns wrote: > > Hello, I read all FAQ and other sources but I could not find this situation, so I thought of asking the experts. > I successfully configured a Raspberry NUT server to control my UPS that powers several devices (NUC with ESXI VMs, Synology NAS etc). > All works well in principle, but I have the following behaviours that I could not
2017 Dec 18
2
Tripp-Lite BCPERS450 shutdown/restart problems
I have a Tripp-Lite BCPERS450, connected to a system running Ubuntu 16.04.3 LTS and NUT 2.7.2-4ubuntu1.2. I had to make my own /lib/systemd/system-shutdown/nutshutdown, but now everything is working except for powering on and off the UPS. Regardless of the settings of offdelay and ondelay in upsconf, and regardless of whether the AC power is on, when I say "upsdrvctl shutdown" the UPS
2020 Jun 28
2
AVR750U Low Power not Triggering Shutdown
Hello, I am having difficulty using NUT to shut down my Netgate SG-1100 (a pfSense router) when the power level of the UPS gets critically low. Here is some relevant information: - OS: pfSense 2.4.5-RELEASE-p1 (FreeBSD 11.3-STABLE) - NUT version: 2.7.4 - Installed from: pfSense package 2.7.4_7 - UPS: AVR750U (Device release number 2) - I have included my config files, output from `upsc`, and
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
Hello everyone! If this message was posted twice, my apologies. I'm having issues with my webmail today... I am using the testing version of NUT from SVN at changeset 582. I have successfully created a stub for newhidups driver for my Dynex DX-800U UPS, but I am completely lost on the customization of it. I've followed the hid-subdrivers.txt instructions and I understand I need to
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks for your help. From: Charles Lepple <clepple at gmail.com> Date: Mon, 18 Dec 2017 19:26:56 -0500 This may sound like an apples-to-oranges comparison, but we did uncover an issue with CyberPower UPSes where the delay values needed to be greater than or equal to 60 (seconds), since they were being rounded down to integer numbers of minutes internally: What was the largest