similar to: howto setup BNT-1500AP on gentoo

Displaying 20 results from an estimated 900 matches similar to: "howto setup BNT-1500AP on gentoo"

2007 Dec 24
3
Driver for Powercom BNT/KIN/IMP/IMD series
Hello all. Try this driver (for nut 2.2.0). See attach. - Trust, KP625AP, Egys models stay as it was - add Powercom's Black Knight Pro model support ( BNT-400/500/600/800/801/1000/1200/1500/2000AP 220-240V ) - add Powercom's King Pro model support ( KIN-425/525/625/800/1000/1200/1500/1600/2200/3000/5000AP[-RM] 100-120,200-240 V) - add Powercom's Imperial model support ( IMP-xxxAP,
2005 Jul 06
0
Powercom BNT-1500AP
Hey all, Does anybody know there is a full working setup for the PowerCom BNT-1500AP. I got some stuff working with the Powercom driver and the type set to "KIN1500AP". But it seems that there is still missing usablity. I was wondering if anybody found any better configs? ---- excerpt of ups.conf [AVR1500] driver = powercom port = /dev/ttyS0 desc =
2013 May 01
1
Powercom BNT-1500AP serial config
Hey all, Finally got around to hooking up my Powercom BNT-1500AP to nut. It's the old serial interface. Connects okay and gets most information, but a couple of data are way off. Any config recommendations or upgrade recommended? I've played with config a little, but no hits yet. Details: NUT version 2.4.3 ups.conf: [ups] driver = powercom port = /dev/ttyS0
2007 Nov 06
1
BNT-1000AP
Hi guys, We've got a BNT-1000AP (powercom) BlackKnight UPS that works with the KIN1500AP model in the powercom driver. Well, almost. It seems the input frequency and the battery charge is swapped around: # upsc blackknight at localhost battery.charge: 46.5 driver.name: powercom driver.parameter.manufacturer: BlackKnight driver.parameter.modelname: BNT-1000AP driver.parameter.port:
2006 Apr 21
1
Powercom BNT-1200AP
Hello I have UPS Powercom Black Knight Pro 1200 (BNT-1200AP) I try to use nut, but powercom driver not understand my model Ok, i try to use type KIN1500AP and it's work But powercom driver can't set UPS's shutdown delay time Also i have powercom's original program (upsmon), and this program can do it What can i do for help to add this function to nut's powercom driver? For
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
Dino, Alexey, there are a number of users suffering issues with your Powercom devices. Could you (Dino, and Keven if possible) please have a look at the below one, from Angela, and check for a fix? I've scheduled to release 2.6.1 next week, and having that fixed is part of the list. 2011/5/16 Angela Williams <angierfw at gmail.com> > Hi All > > On Friday 13 May 2011 at
2006 Aug 17
1
powercom upstype identify problem
Mr Claesson, with my current configuration, the ups.status when the UPS is disconnected from the mains is "OB". There is no more "OB BOOST". Now my upsd.users is: [root] password = password allowfrom = localhost upsmon master actions = SET instcmds = ALL and upsmon.conf is: RUN_AS_USER root MONITOR Inform@localhost 1 root password master MINSUPPLIES 1 SHUTDOWNCMD
2011 Oct 04
2
PowerCOM BNT-800AP (0d9f:0004)
Hello. I've been trying to got it work but haven't luck. I'm using NUT 2.6.0-1 under Windows XP with libusb driver installed (USB\VID_0D9F&PID_0004&REV_0001). I had tryed all options with such config: *PWCOM] driver = usbhid-ups port = auto vendorid = 0d9f desc = "Powercom BNT-800AP" type=BNT* * *Here is output from CMD:*
2006 Dec 22
1
Powercom BNT-1200AP driver
Hello. What about driver for my UPS? I have changed the powercom driver for myself, but I have made it not absolutely correctly. However, somehow this driver works. Now i have protocol spec for powercom BNT series and attach it to this email. It can be interesting to authors? -- ? ?????????, ??????? ??????? mailto:alex@reutman.ru JID: alex@reutman.ru ICQ: 5052225 -------------- next part
2017 Apr 28
3
Powercom BNT-2000AP(USB)
Hello all! Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent four last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2. # dmesg|grep -i powercom ugen0.3: <POWERCOM Co.,LTD> at usbus0 uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0 uhid0: <POWERCOM
2009 Jul 27
1
Powercom BNT-1000CS
Hello. I have recently purchased a Powercom BNT-1000CS(Black Knight CS). I am new to NUT(and am not a programmer), but I have noticed that this model does not work with NUT. I am willing to provide details about this UPS for anyone who would like to add support for it(i dont know how to get much info though, so you'll have to tell me how). For starters, this is what happens when I do
2009 Dec 27
4
XPCC XVRT-1000 driver
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Has anyone used nut with a XPCC UPS, in particular one of the XVRT units? Their supplied monitoring tool "works", but I'd really prefer to use nut if possible. I've systematically gone through each of the drivers in /lib/nut and none seem to talk with the unit properly. I'll be talking with a XPCC support person tomorrow, though
2006 Jul 08
0
Powercom BNT-600AP and NUT (powercom driver)
Hello, I'm new there. I bought an UPS Powercom BNT-600AP. It's compatible in NUT with driver powercom and protocol type KIN1500AP. But I have a simple problem: the 'upsc' shows wrong values in battery.charge (maybe in other rows also /ups.load, voltages?/) - if battery is 100% charged it shows only 92.6% or 93.0%. I thing I have wrong values in driver parameters: batteryPercentage,
2006 Aug 18
0
(no subject)
Dear Mr Claesson, prepare for quite a long letter from me. I hope you will have time to read it. I bestowed a whole morning on trying to identify the correct upstype. Here are the results: root@marto:/home/marto# /usr/local/ups/bin/powercom -DD -u root -a Inform -x type=KP625AP Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.4) debug level is '2'
2012 Nov 13
1
PowerCom BNT-600AP on ubuntu 12.04.1 AMD64
Hello people, I use a BNT-600AP from PowerCom, and on driver loading (nut service start) the UPS goes off so I cannot use nut as service as the computer goes off with the UPS. When the computer is not using the UPS, but still connected, I see that the UPS goes off for a very short time, does battery check and goes on again. I don't know how to deal with this issue as I cannot use my UPS
2005 Dec 30
2
BNT600AP
Hi, I have a little problem with PowerCom BNT600AP after running driver I see: root@rask> powercom -D /dev/ttyS1 Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.2) debug level is '1' Values of arguments: manufacturer : 'PowerCom' model name : 'Unknown' serial number : 'Unknown' line
2005 Aug 19
1
Sustainer S-1000C (Powercom protocol)
Hi, I've sent the following message 3 weeks ago, yet have recieved no reply at all. I don't want to nag, but could anyone please help me? Thanks, Dror ------------------ Hi, I have a UPS of the Israeli company Sustainer, model S-1000C (http://www.sustainer.co.il/data/files/specifications%20smart%20en.pdf - don't worry, it's in english...). I've been trying to connect to
2013 Jun 05
2
several problems with Powercom BNT-500AP
OS name and version: pi at raspberrypi ~ $ cat /etc/*release PRETTY_NAME="Debian GNU/Linux 7.0 (wheezy)" uname -a Linux raspberrypi 3.6.11+ #393 PREEMPT Fri Mar 8 16:36:28 GMT 2013 armv6l GNU/Linux exact NUT version pi at raspberrypi ~ $ dpkg -s nut Package: nut ... Version: 2.6.4-2.3 NUT installation method: package exact device name and related information:
2009 Sep 19
1
Powercom 600AP USB support
Hi, I know it's been a topic many times here, but I've searched the archives, googled for days, and I simply don't believe, that there is still no solution to this. I'm using a PowerCom BNT-600AP ups with usb port. I've downloaded the latest version from svn, compiled it, and tried to use it: * megatec(_usb) - no luck, it did not find the UPS (I?ve read in this list, that
2013 Jun 08
2
several problems with Powercom BNT-500AP
Thanks for the support. Here's list of when transition to battery with return to utility power within a few seconds occurred in last few days: Wednesday 1:41 11:48 11:54 12:59 13:42 14:42 18:13 18:14 Thursday 5:23 Friday 5:12 7:39 7:43 Saturday 7:34 Here's list of when messages that battery needs replacement occurred: Wednesday 20:34 Thursday 9:07 23:09 Friday 18:25 Saturday 7:32 19:47