similar to: initial configuration assistance

Displaying 20 results from an estimated 10000 matches similar to: "initial configuration assistance"

2006 Jun 19
4
Backups 300VA (BK-300C) Drivers
Hi, What driver should i use with APC BK-300C ? Michale Plourde Digicom Technologies
2010 Dec 23
2
upsd crashes with a "broken pipe" error
In /var/log/syslog Dec 23 13:04:50 ************** upsmon[2010]: Poll UPS [rack1ups at localhost] failed - Write error: Broken pipe After this, there is no longer a upsd daemon running. Error messages follow: Dec 23 13:04:50 ************** upsmon[2010]: Communications with UPS rack1ups at localhost lost ... Dec 23 13:04:55 ************** upsmon[2010]: UPS [rack1ups at localhost]: connect
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the manufacturer's PowerChute software and smart signaling, so I have decided to try NUT. The smartups driver can't make contact through the serial port. Since this is rack-mounted, it comes with a 940-1524 serial cable. As far as I can tell, this is supposed to work with smart signaling. Here's my ups.conf:
2006 Mar 02
1
Problem after reboot
Hello all, Rebooted my server by mistake (don't ask...) - everything was working OK before the reboot, but after the reboot, NUT stopped working - so had a look and I found I couldn't track the exact problem - I'm quite stumped as there's nothing indicating that there's a problem, but it just doesn't work... In a nutshell.... destiny:/usr/local/ups/bin# ./upsdrvctl
2006 Mar 02
1
Problem after reboot
Hello all, Rebooted my server by mistake (don't ask...) - everything was working OK before the reboot, but after the reboot, NUT stopped working - so had a look and I found I couldn't track the exact problem - I'm quite stumped as there's nothing indicating that there's a problem, but it just doesn't work... In a nutshell.... destiny:/usr/local/ups/bin# ./upsdrvctl
2009 Aug 14
1
Have an older Back-UPS Pro 1400(BP1400) can't get detailed info.
I just installed nut, and I it is detected but I don't get any usefull information. I have the serial cable that came with it which is a 940-0024C and I tried setting that in the driver, but no difference. What can I do to get stuff like battery voltage and such? Thanks, Brian upsc ups1 at localhost driver.name: apcsmart driver.parameter.cable: 940-0024C driver.parameter.pollinterval: 2
2006 Aug 13
2
can't get UPSDRV to see serial port
First, a little history; nut has been working on this system for about two years. It was a Fedora Core 2 (3?) system that I wiped and installed SUSE 10.1 on so I'm fairly confident of the hardware. I thought I'd saved the nut configuration details before I did the reinstall, but can't find them. (D'oh!) The UPS is an APC BackUPS Pro 420. The cable is a clone of the APC
2006 Sep 04
5
Smart-UPS with SuSE 9.0/Nut
I have a Dell PE 2850 connected via 940-0024C cable to serial port on the UPS mentioned above. I've used apt-get to install nut-2.0.2-3 and attempted to configure based on the documentation. So far I'm getting the following when I try to start ups daemon: server:/etc/ups # /etc/init.d/ups start Starting service NUT: -> Starting UPS driver: Network UPS Tools - UPS driver controller
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
Listmates, After wrangling with the voltage value on the CyberPower 1000AVRLCD and now having 2 of them working, I though it would be a simple matter to move my APC BP650 from apcupsd to nut so that all 3 servers would be monitored on the same web interface. The APC is attached to an older box running openSuSE 11.0 with nut-2.2.2-66.1. (nut-classic). The APC BP650 uses a serial connection
2009 Aug 03
1
SmartUPS-600 problem with 940-0024C cable
Hey guys, I built my own 940-0024C cable as described here: http://www.networkupstools.org/cables/940-0024C.jpg My problem is that I can't receive anything. Sending (e.g. through minicom or my own application) works fine. Nut itself is not able to detect My UPS or anything else. <snip> [myups] driver = apcsmart port = /dev/ttyS0 cable = 940?0024C # also tested without cable option
2007 Jul 31
1
Proposed apcsmart driver patch
G'day y'all, Here's a tiny patch set for drivers/apcsmart.c and drivers/apcsmart.h. Adds APC SmartUPS 1250 ("8QD" case) + 940-0024C recognition to apcsmart. (Unpatched apcsmart.c v1.99.8 misidentifies the SmartUPS 1250 as a "dumb" UPS.) For NUT 2.0.5+. NUT 2.0.5: Patches apply successfully. Builds successfully. Works as expected under Ubuntu 7.04. NUT 2.2:
2007 Jun 24
1
upssched. Again.
Hi everyone, Here I am with my second attempt to persuade upssched to do things; for some reasons it just won't! Or if it runs, it never runs the script. OK, the story first: 2.0.3 (conveniently comes as RPMs by default on FC6) running on FC6; APC Smart-UPS 750 via serial connection all working fine. Here are the main files: /etc/sysconfig/ups SERVER=yes MODEL=apcsmart DEVICE=/dev/ttyS0
2009 May 25
1
APC Smart UPS 900i
Hi, I'm running an old APC Smart UPS 900i. As there isn't any software from APC which supports this UPS anymore, I've installed NUT (Gentoo Ebuilds), but version 2.0.5 and version 2.2.2 loose connection to the UPS while version 2.4.1 and SVN version don't show any settings and there are no instant commands. The only information I can get are: driver.name: apcsmart
2012 Mar 08
18
some fixes, improvements, and new features (EPO and DYING) for NUT
Here are a series of my recent changes to NUT. The first few in the set are primarily little fixes and improvements. In among those are a few for .gitignore files which of course you can ignore for SVN, and there's one for a commit to a generated file which of course should not be tracked in any VCS. Then there are a couple or three to do with generating the header files used by
2007 Jan 12
1
Trouble connecting to apc smart 1500 via serial cable
Hello. I've been running a two machine setup with a mge-shut for some time without problems, and now I'm configuring a three machine setup with an APC Smart 1500. The UPS has three machines connected to it, in a peculiar way: one windows machine is connected via USB. The second windows machine is using an agent to monitor messages from the first windows machine. Then, I have a GNU/Linux
2006 Jun 14
3
Trouble Configuring NUT with Gamatronic USB
Hi I am running FC5 with nut coming from the fc5 extras repositories. I am trying to configure a Gamatronic D-Compact ups. The cable that came with the ups has a serial connector on one end and a usb on the other. cat /proc/bus/usb/devices produces T: Bus=01 Lev=01 Prnt=01 Port=01 Cnt=01 Dev#= 4 Spd=1.5 MxCh= 0 D: Ver= 1.10 Cls=00(>ifc ) Sub=00 Prot=00 MxPS= 8 #Cfgs= 1 P:
2006 Dec 27
1
right problem with ups belkin (model who work with nut)
hi i have a belkin ups here some setting chmod 0600 /dev/hiddev0 chown nut:root /dev/hiddev0 linux:/home/sonia # /usr/lib/ups/driver/upsdrvctl start Network UPS Tools - UPS driver controller 2.0.4 Network UPS Tools: New USB/HID UPS driver 0.28 (2.0.4) No matching USB/HID UPS found Driver failed to start (exit status=1) linux:/home/sonia # /usr/lib/ups/driver/upsdrvctl -u root start
2006 Sep 26
4
Tripp-Lite OMNI650LCD
Hello all; I am new to this list. Recently we have been getting these cheap new Tripp-Lite "LCD" style UPS'es around here, and I was surprised to find the lack of Linux support. The model name is OMNI650LCD. Anyway, I tried the tripplite_usb driver and got a message instructing me to contact this mailing list. I might try to fix the problem myself, if I was more familiar with the
2013 Sep 12
3
UPS repeater configuration using localhost
Hello, I'm trying to setup a UPS configuration whereas I have one physical UPS but two UPS entities loaded by the system used by different network slaves. In my ups.conf configuration I have ... [ups] driver = apcsmart port = /dev/ttyS0 desc = "APC UPS" [qnapups] driver = dummy-ups port = ups at localhost desc = "APC UPS for
2016 Jun 27
2
query "Data stale" from the cmdline
Hello, is there a way to query from the cmdline if the UPS data is stale? "upsc" outputs a lot of information, but not if the data is stale. Example output from a "stale" UPS on the server: (nut version: nut-2.7.2-3.el7) # upsc apcsmart battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.mfr.date: 2014/09/01 battery.runtime: 1320