2006 Apr 08
2
Powerware 9120 serial connection via USB/serial dongle
I decided to try this to see if it worked better since
Powerware decided to build in some oddball USB
protocol instead of using a HID UPS profile, but it
doesn't seem to work. The USB/serial dongle is
recognized by Linux and added as /dev/ttyUSB0, owned
by group "dialout", so I had to add the nut user to
the dialout group. In the compatibility list, the
proper driver for the
2014 Nov 03
0
RFC: new variable battery.status (was: [PATCH] upscode2: Report ABM Status)
Hi,
Am 13.02.2012 um 18:58 schrieb Arnaud Quette:
> 2012/2/6 thomas schorpp <thomas.schorpp at googlemail.com>:
>> Hi,
>
> Hi Thomas,
>
>> I want the driver report the battery status from ABM charging controllers
>> -patch attached- :
>
> For now, I've tracked your patch here:
>
2014 Nov 04
2
RFC: new variable battery.status
THANKYOUTHANKYOUTHANKYOUTHANKYOU!!!!!!
There was a smaller patch posted to the list for lines
-1389,9 +1390,10
a couple years ago, it helped some - BUT - it was still buggy.
I have a Compaq R3000, I will get this patch integrated pronto and test
Note that since the UPS relies on the voltage from the battery pack to
determine state of charge, it is quite useful to add in the battery pack
2012 Feb 13
3
RFC: new variable battery.status (was: [PATCH] upscode2: Report ABM Status)
2012/2/6 thomas schorpp <thomas.schorpp at googlemail.com>:
> Hi,
Hi Thomas,
> I want the driver report the battery status from ABM charging controllers
> -patch attached- :
thanks for your patch.
since it introduces a new variable (battery.status.abm), I prefer to
step back and think to something useful more widely.
thus, I'm thinking about a generic
2007 May 25
0
Patch -- SVN revision in the version string
This is the patch to include SVN revision level in version number displays.
There should be two enclosures; the patch itself and a new source file.
common/upsversion.c.
upversion.c defines a single function. upsversion(), that returns a version
string for display. Some Makefile trickery ensures that this file will
be recompiled whenever the project's SVN revision level has changed since
it
2013 Sep 22
1
Question on weird output from a Compaq R3000
Hi All,
I put my Compaq R3000 UPS on NUT.
Every once in a while the battery alarm light turns on, on the front
of the UPS. Maybe once every couple of days or so. When that happens
I get the following output in /var/log/messages:
Sep 22 01:51:46 mail upscode2[90734]: Unknown response to UPDS: .20 MOUL1
Sep 22 01:51:46 mail upscode2[90734]: Unknown response to UPDS: 0119.20
MOIL1
Sep 22
2008 Dec 23
2
Exide NetUPS SE (aka Powerware 5119 etc)
My UPS is an Exide NetUPS SE PRC1500i (1500 VA), also known as
Powerware 5119, according to Karl Schmidt
(http://lists.alioth.debian.org/pipermail/nut-upsuser/2005-July/000026.html)
also Deltec PowerRite Pro II, and according to
http://www.usedups.de/compaq_ups.html also Compaq R3000h. I am not
sure if the information in http://www.bps.hu/powerware/model_en.html
is to be interpreted as that it was
2008 Dec 23
2
Exide NetUPS SE (aka Powerware 5119 etc)
My UPS is an Exide NetUPS SE PRC1500i (1500 VA), also known as
Powerware 5119, according to Karl Schmidt
(http://lists.alioth.debian.org/pipermail/nut-upsuser/2005-July/000026.html)
also Deltec PowerRite Pro II, and according to
http://www.usedups.de/compaq_ups.html also Compaq R3000h. I am not
sure if the information in http://www.bps.hu/powerware/model_en.html
is to be interpreted as that it was
2010 Mar 03
1
using upscode2 driver with Powerware 5119 RM
I've got a Powerware 5119 RM UPS.
driver.list says to use "genericups upstype=20", however I know this UPS
supports the UPS Code II protocol, so I wanted to use the upscode2 driver. It
took some hacking but finally it works.
I'm using NUT 2.4.1 and upscode2 driver version 0.87 (however the latest r2350
version of upscode2.c isn't significantly different, so I think all
2006 Feb 10
1
Character-encoding in code and docs
Hi fellows,
are there any policy on character-encoding in this project?
The upscode2 driver did originally contain some nordic letters encoded
in latin-1 (?, ?), but these have now transformed into garbage.
I would like to restore these, but in what encoding? UTF-8?
/Niels
--
Niels Baggesen - @home - ?rhus - Denmark - nba@users.sourceforge.net
The purpose of computing is insight, not numbers
2007 May 31
1
powerware plus 5xx / fiskars 9x00
Hi,
just wanted to confirm that Fiskars UPS 9000 series (aka Powerware Plus
500 series) with optional UPS Information Unit works fine with upscode2
driver. Tested on Fiskars 9200 (20kVA/400V/3ph).
Regards,
--
Sebastian Zagrodzki Dzia? Sieciowy ICM, Uniwersytet Warszawski
s.zagrodzki at net.icm.edu.pl (+48-22) 5520527, 8268009, fax. 8284195
http://www.net.icm.edu.pl/
2006 Feb 25
3
Compaq R1500 UPS and Linux
-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
- -----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Hi!
Has anyone gotten it working at all with Linux :) I picked one up for
thiry bucks and would love to monitor it!
Liz
- -----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.1 (Darwin)
iD8DBQFD/5fEIACpLcG4dhwRAmeCAJ9+8FGXqKoOlZdkw/KFXb9n0PEemwCdHaoD
NVnv7JjmBAjNsExK6WzAdnA=
=pcPX
- -----END PGP
2023 Jul 05
1
failed after upgrade - upscode2: Missing UPCL after UPCL
On 7/5/23 03:17AM, Jim Klimov wrote:
> Ah, I thought you missed in my earlier reply the part about a bug with debug printouts in 2.8.0 (fixed on master since),
> did not comment on that when you replied with quoting... So, for now options are to bump debugging to 3+ or to build
> your own in one of many ways possible :\
I think I'm not following you - with debug 3 -->> it
2013 Feb 10
1
Data string for 2 instant commands to Powerware 9110
Hi all
I was wondering if one of you kind gentlemen (or ladies) would assist me
in finding the data string required to tell my ups to turn on and off.
No more no less :)
I guess it would be the actual string of an instant command sent down
the rs232 port to the ups.
I have no programming experience and have done a list search to no
avail. Sorry to trouble you with this.
I have a lan to
2017 Jul 22
0
Compaq R3000h support
On Jul 22, 2017, at 4:13 AM, Tomas Larsson <tomas.larsson at enrad.se> wrote:
>
> I am planning to install NUT (master) on a headless CENTOS 6.8 system.
> Connect the UPS with seral cable.
It looks like this might be using the upscode2 driver (UPScode-II protocol), right?
> Now my main question is, Does NUT support the power segments on the UPS.
> My intention is to be able
2014 Nov 08
1
RFC: new variable battery.status
On 11/8/2014 6:54 AM, thomas schorpp wrote:
> Dear Ted,
>
> Am 07.11.2014 um 17:47 schrieb Ted Mittelstaedt:
>> On 11/3/2014 9:25 PM, thomas schorpp wrote:
>>> Hi Ted,
>>>
>>> Am 04.11.2014 um 04:12 schrieb Ted Mittelstaedt:
>>>>
>>>
>>>> Note that since the UPS relies on the voltage from the battery pack to
2014 Feb 19
3
Logic problem in NUT with upscode2 driver
Hi All,
I have what is probably a 12 year old (or older) Compaq R3000 UPS
plugged into a FreeBSD 8 system running NUT version 2.6.5
This UPS contains a total of 16 batteries in 2 banks of 8,
each battery is 6 volts and the bank produces 50 volts.
The UPS monitors battery voltage and the battery charger in
the UPS works like this. For about 2 days it will apply a
charge/float/topping
2011 Feb 22
1
Hardware compatibiltiy list -- NetUPS
Hallo,
I own a NETUPS 450 (Model on the sticker: PRM 450i; upsstats reports
"UPS 450 VA FW -0024") which perfectly works with the upscode2 driver.
Maybe you want to add it to your list, even if the model is >10 years
old.
I suppose this is true for the whole series. According manual the come
in the 450VA, 700VA, 1000VA and 1500VA strengths.
They have been sold under different
2009 Jan 29
1
Fwd: upscode2.c
----- Doorgestuurd bericht van dkbrig at gmail.com -----
Datum: Thu, 29 Jan 2009 11:16:06 -0600
Van: Danny <dkbrig at gmail.com>
Onderwerp: upscode2.c
Aan: adkorte-guest at alioth.debian.org
Hi,
I apologize if you are not the correct person, but I was wanting to
submit a bug report for the upscode2.c driver but could not find a way
to do that from the NUT website.
2014 Feb 20
0
Logic problem in NUT with upscode2 driver
On Feb 19, 2014, at 12:50 PM, Ted Mittelstaedt wrote:
> Worse, however, is if there's a power failure right near the end
> of the 2-days-off cycle. That happened to me last week - it was a
> short duration 15 second loss - and the upscode2 driver decided it needed to issue a forced shutdown.
>
> Very likely this was because upscode2 had decided the batteries
> were